Skip to main content
Window · Vinyl Frame NFRC CDW · Product Line CDW-A-15

California Deluxe Windows Industries, Inc. — S-3505 Double Slider · Double Slider

EPA ENERGY STAR Version 7.0 certifies 28 variants inside California Deluxe Windows Industries, Inc. S-3505 Double Slider, combining Vinyl frame construction with U-Factors spanning 0.24 to 0.31 and SHGC 0.11 to 0.20. Qualifying for North-Central, South-Central, Southern, this Double Slider family places #1,034 of 1,352 among 1,352 Window families and posts 0.05 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

Min U-Factor
0.24
SHGC Range
0.11-0.20
Certified Options
28
Category Standing
#1,034 of 1,352

How does California Deluxe Windows Industries, Inc. S-3505 Double Slider compare thermally against Window peers?

California Deluxe Windows Industries, Inc. S-3505 Double Slider achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. S-3505 Double SliderHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing S-3505 Double Slider (U 0.24).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

S-3505 Double Slider Cohort StandingMin U-Factor 0.24 stands at rank #1,034 of 1,352, outperforming 13.2% of peers.Min U-Factor 0.24Rank #1,034 of 1,352 (13.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), S-3505 Double Slider is 0.04 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.24-0.31.

Mapping NFRC SHGC values (0.11 to 0.20) against ENERGY STAR Version 7.0 targets approves North-Central, South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.11 lowers cooling load.

Registry history records EPA FENSTAR licensing on 2023-05-31 and v7.0 data certification on 2026-03-25. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.24 conducts 144.0 BTU/hr (+12.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 28 certified glazing combinations for S-3505 Double Slider (NFRC CDW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 8 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 24 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 28 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does California Deluxe Windows Industries, Inc. produce?

Compare other active California Deluxe Windows Industries, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to California Deluxe Windows Industries, Inc. S-3505 Double Slider appear below.

What U-Factor and SHGC range does California Deluxe Windows Industries, Inc. S-3505 Double Slider achieve?

California Deluxe Windows Industries, Inc. S-3505 Double Slider spans 28 certified configurations with U-Factors between 0.24 and 0.31 and SHGC values from 0.11 to 0.20. Ranked #1,034 of 1,352 Window families, it carries 0 Most Efficient options.

Can homeowners install S-3505 Double Slider in cold Northern ENERGY STAR counties?

California Deluxe Windows Industries, Inc. S-3505 Double Slider holds zero Northern Zone qualifications (min U 0.24). Homeowners in northern heating zones should skip this line and select an assembly reaching <= 0.22 U-Factor or Equivalent SHGC.

How much winter heat loss does S-3505 Double Slider conduct across a 15 sq ft opening?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.24 U-Factor yields 144.0 BTU/hr conductive transfer (+9.1% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

Who should NOT choose California Deluxe Windows Industries, Inc. S-3505 Double Slider for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on S-3505 Double Slider options exceeding U 0.22. Additionally, do not order Dual-Slide Horizontal (HSXX) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Is S-3505 Double Slider suitable for sunbelt cooling-dominated homes?

Warm-climate homeowners have 28 Southern-approved options within S-3505 Double Slider spanning SHGC down to 0.11. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Are all 28 S-3505 Double Slider configurations ENERGY STAR Most Efficient?

All 28 S-3505 Double Slider listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

What federal compliance checks govern 2026 S-3505 Double Slider window swaps?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current S-3505 Double Slider retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

How do you cross-check NFRC CDW and product line CDW-A-15 on delivery?

Inspectors match the temporary NFRC sticker (U 0.24-0.31, SHGC 0.11-0.20) against permit drawings for line CDW-A-15. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for California Deluxe Windows Industries, Inc. S-3505 Double Slider come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros