Window · Vinyl Frame NFRC PWS · Product Line PWS-A-23

Paradigm Window Solutions — 500/5000 Double Hung · Double Hung

Paradigm Window Solutions engineered the 500/5000 Double Hung Double Hung line for Northern, North-Central, South-Central, Southern, certifying 28 glass-spacer combinations from 0.24 to 0.31 U-Factor and 0.22 to 0.50 SHGC. Relative to other Vinyl models tracked under NFRC PWS, its minimum U-Factor is 0.05 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median.

Min U-Factor
0.24
SHGC Range
0.22-0.50
Certified Options
28
Category Standing
#1,034 of 1,352

How does Paradigm Window Solutions 500/5000 Double Hung compare thermally against Window peers?

Paradigm Window Solutions 500/5000 Double Hung achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 500/5000 Double HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing 500/5000 Double Hung (U 0.24).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

500/5000 Double Hung Cohort StandingMin U-Factor 0.24 stands at rank #1,034 of 1,352, outperforming 13.2% of peers.Min U-Factor 0.24Rank #1,034 of 1,352 (13.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Paradigm Window Solutions 500/5000 Double Hung standing at #1,034 of 1,352 certified Window product series, tied with 139 others at 0.24, more insulating than 13.2% of Window lines. Comparing Vinyl profiles alone (median 0.19) shows +0.05 before selecting Low-E tiers.

Climate coverage for Paradigm Window Solutions 500/5000 Double Hung spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 13 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Lifecycle documentation anchors PWS to 2024-05-21 certification (FENSTAR issued 2018-01-10). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 144.0 BTU/hr conductive loss (+9.1% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 28 certified glazing combinations for 500/5000 Double Hung (NFRC PWS) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 13 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 14 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 1 package (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 2 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Paradigm Window Solutions produce?

Compare other active Paradigm Window Solutions certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Paradigm Window Solutions 500/5000 Double Hung appear below.

What thermal performance numbers separate Paradigm Window Solutions 500/5000 Double Hung from peers?

Paradigm Window Solutions 500/5000 Double Hung spans 28 certified configurations with U-Factors between 0.24 and 0.31 and SHGC values from 0.22 to 0.50. Ranked #1,034 of 1,352 Window families, it carries 0 Most Efficient options.

Is 500/5000 Double Hung approved for Northern Zone heating climates?

Northern qualification on 500/5000 Double Hung relies on EPA Equivalent solar pathways rather than prescriptive <= 0.22 limits, since its best glass sits at U 0.24. Exactly 13 packages pass Northern thresholds with air leakage <= 0.3 cfm/ft2.

How does a 3x5 ft 500/5000 Double Hung window perform under a 40 deg F temperature drop?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 500/5000 Double Hung at U 0.24 conducts 144.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

What are the practical limitations of specifying 500/5000 Double Hung?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 500/5000 Double Hung options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

Does 500/5000 Double Hung meet Southern hot-climate SHGC caps (<= 0.23)?

Exactly 2 500/5000 Double Hung options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.22 rather than higher 0.50 glass.

Does 500/5000 Double Hung carry EPA Most Efficient certification across its lineup?

All 28 500/5000 Double Hung listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

What federal compliance checks govern 2026 500/5000 Double Hung window swaps?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Paradigm Window Solutions upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How can homeowners confirm delivered Paradigm Window Solutions 500/5000 Double Hung units match permits?

Verify NFRC ID PWS and series PWS-A-23 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Paradigm Window Solutions 500/5000 Double Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)