Skip to main content
Window · Vinyl Frame NFRC AVT · Product Line AVT-M-2

Advent Windows and Doors — Ascend Series SH · Single Hung

Advent Windows and Doors Ascend Series SH is a Single Hung assembly with a Vinyl frame that reaches a minimum U-Factor of 0.24 across 34 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #1,034 of 1,352 in Window, its thermal floor is 0.04 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.13 to 0.50.

Min U-Factor
0.24
SHGC Range
0.13-0.50
Certified Options
34
Category Standing
#1,034 of 1,352

How does Advent Windows and Doors Ascend Series SH compare thermally against Window peers?

Advent Windows and Doors Ascend Series SH achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Ascend Series SHHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing Ascend Series SH (U 0.24).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Ascend Series SH Cohort StandingMin U-Factor 0.24 stands at rank #1,034 of 1,352, outperforming 13.2% of peers.Min U-Factor 0.24Rank #1,034 of 1,352 (13.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 3 certified Advent Windows and Doors series, this Single Hung offers a 0.05 U-Factor adjustment span between 0.29 entry options and 0.24 top-performing glazing. Category standing is #1,034/1,352 (tied with 139 others at 0.24, more insulating than 13.2% of Window lines).

Mapping NFRC SHGC values (0.13 to 0.50) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 2 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Registry history records EPA FENSTAR licensing on 2026-01-09 and v7.0 data certification on 2026-07-31. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.24 conducts 144.0 BTU/hr (+12.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 34 certified glazing combinations for Ascend Series SH (NFRC AVT) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 2 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 4 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 24 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 32 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Advent Windows and Doors produce?

Compare other active Advent Windows and Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Advent Windows and Doors Ascend Series SH appear below.

Where does Advent Windows and Doors Ascend Series SH stand thermally among ENERGY STAR Window lines?

Testing puts Advent Windows and Doors Ascend Series SH at rank #1,034 of 1,352 Window entries with U 0.24 to 0.29 across 34 configurations. Solar heat gain ranges between 0.13 and 0.50 across Northern, North-Central, South-Central, Southern.

Which glazing options in Advent Windows and Doors Ascend Series SH meet Northern climate limits?

With a 0.24 minimum U-Factor, Advent Windows and Doors Ascend Series SH cannot satisfy prescriptive <= 0.22 Northern targets, yet 2 high-SHGC packages meet EPA's solar-gain Equivalent route for cold northern homes.

What conductive BTU/hr difference separates Ascend Series SH from the 0.22 Northern rule?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.24 U-Factor yields 144.0 BTU/hr conductive transfer (+9.1% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

What homeowner profiles are a poor match for Advent Windows and Doors Ascend Series SH?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Ascend Series SH options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

How many Ascend Series SH glazing packages pass Southern solar-heat rules?

Yes, Ascend Series SH holds 32 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.13 SHGC in cooling climates.

What glazing share inside Ascend Series SH qualifies as Most Efficient?

Zero glazing builds inside Ascend Series SH's 34 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

What federal compliance checks govern 2026 Ascend Series SH window swaps?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Advent Windows and Doors upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

What permanent glass etch marks verify Ascend Series SH after sticker removal?

Inspectors match the temporary NFRC sticker (U 0.24-0.29, SHGC 0.13-0.50) against permit drawings for line AVT-M-2. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Advent Windows and Doors Ascend Series SH come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros