Skip to main content
Window · Vinyl Frame NFRC PWS · Product Line PWS-A-24

Paradigm Window Solutions — 500/5000 Horizontal Slider · Double Slider

Across 11 Paradigm Window Solutions certified families, 500/5000 Horizontal Slider supplies 34 Double Slider configurations starting at 0.24 U-Factor and 0.22 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.31 U-Factor and 0.48 SHGC. Its thermal floor ranks #1,034 of 1,352 category entries—0.04 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.24
SHGC Range
0.22-0.48
Certified Options
34
Category Standing
#1,034 of 1,352

How does Paradigm Window Solutions 500/5000 Horizontal Slider compare thermally against Window peers?

Paradigm Window Solutions 500/5000 Horizontal Slider achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 500/5000 Horizontal SliderHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing 500/5000 Horizontal Slider (U 0.24).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

500/5000 Horizontal Slider Cohort StandingMin U-Factor 0.24 stands at rank #1,034 of 1,352, outperforming 13.2% of peers.Min U-Factor 0.24Rank #1,034 of 1,352 (13.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Paradigm Window Solutions 500/5000 Horizontal Slider standing at #1,034 of 1,352 certified Window product series, tied with 139 others at 0.24, more insulating than 13.2% of Window lines. Comparing Vinyl profiles alone (median 0.19) shows +0.05 before selecting Low-E tiers.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 12 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Lifecycle documentation anchors PWS to 2024-05-21 certification (FENSTAR issued 2018-01-10). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 144.0 BTU/hr conductive loss (+9.1% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 34 certified glazing combinations for 500/5000 Horizontal Slider (NFRC PWS) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 12 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 14 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 4 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 8 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Paradigm Window Solutions produce?

Compare other active Paradigm Window Solutions certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Paradigm Window Solutions 500/5000 Horizontal Slider appear below.

What U-Factor and SHGC range does Paradigm Window Solutions 500/5000 Horizontal Slider achieve?

Paradigm Window Solutions 500/5000 Horizontal Slider spans 34 certified configurations with U-Factors between 0.24 and 0.31 and SHGC values from 0.22 to 0.48. Ranked #1,034 of 1,352 Window families, it carries 0 Most Efficient options.

How does Paradigm Window Solutions 500/5000 Horizontal Slider satisfy Version 7.0 Northern criteria?

Northern qualification on 500/5000 Horizontal Slider relies on EPA Equivalent solar pathways rather than prescriptive <= 0.22 limits, since its best glass sits at U 0.24. Exactly 12 packages pass Northern thresholds with air leakage <= 0.3 cfm/ft2.

How does a 3x5 ft 500/5000 Horizontal Slider window perform under a 40 deg F temperature drop?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 500/5000 Horizontal Slider at U 0.24 conducts 144.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

Who should NOT choose Paradigm Window Solutions 500/5000 Horizontal Slider for a residential project?

Do not specify 500/5000 Horizontal Slider without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 500/5000 Horizontal Slider options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

How many 500/5000 Horizontal Slider glazing packages pass Southern solar-heat rules?

Warm-climate homeowners have 8 Southern-approved options within 500/5000 Horizontal Slider spanning SHGC down to 0.22. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Are all 34 500/5000 Horizontal Slider configurations ENERGY STAR Most Efficient?

ENERGY STAR Most Efficient designation is absent across all 34 500/5000 Horizontal Slider options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

How do the 25C sunset and pre-1978 Lead RRP rules affect 500/5000 Horizontal Slider?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How do building inspectors verify 500/5000 Horizontal Slider glass specs on job sites?

Confirm both the paper NFRC label and permanent corner glass etch match line PWS-A-24 and NFRC ID PWS before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Paradigm Window Solutions 500/5000 Horizontal Slider come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros