Paradigm Window Solutions — 500/5000 Horizontal Slider · Double Slider
Across 11 Paradigm Window Solutions certified families, 500/5000 Horizontal Slider supplies 34 Double Slider configurations starting at 0.24 U-Factor and 0.22 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.31 U-Factor and 0.48 SHGC. Its thermal floor ranks #1,034 of 1,352 category entries—0.04 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.24
- SHGC Range
- 0.22-0.48
- Certified Options
- 34
- Category Standing
- #1,034 of 1,352
How does Paradigm Window Solutions 500/5000 Horizontal Slider compare thermally against Window peers?
Paradigm Window Solutions 500/5000 Horizontal Slider achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Thermal positioning shows Paradigm Window Solutions 500/5000 Horizontal Slider standing at #1,034 of 1,352 certified Window product series, tied with 139 others at 0.24, more insulating than 13.2% of Window lines. Comparing Vinyl profiles alone (median 0.19) shows +0.05 before selecting Low-E tiers.
Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 12 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).
Lifecycle documentation anchors PWS to 2024-05-21 certification (FENSTAR issued 2018-01-10). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 144.0 BTU/hr conductive loss (+9.1% vs the 132.0 BTU/hr baseline at U=0.22).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 34 certified glazing combinations for 500/5000 Horizontal Slider (NFRC PWS) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Equiv. Path | <= 0.22 | >= 0.17 | 12 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 14 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 4 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 8 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Advent Windows and Doors — Ascend Series HS | Vinyl | 0.24 | 0.13 | 34 |
| Advent Windows and Doors — Ascend Series SH | Vinyl | 0.24 | 0.13 | 34 |
| Regency Plus, Inc. — 2000 Double Slider | Vinyl | 0.24 | 0.17 | 35 |
| Morfe Windows LLC — Double Hung Window | Vinyl | 0.24 | 0.18 | 36 |
| California Deluxe Windows Industries, Inc. — S-3505 Double Slider | Vinyl | 0.24 | 0.11 | 28 |
What other certified series does Paradigm Window Solutions produce?
Compare other active Paradigm Window Solutions certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Paradigm Window Solutions 500/5000 Horizontal Slider appear below.
What U-Factor and SHGC range does Paradigm Window Solutions 500/5000 Horizontal Slider achieve?
Paradigm Window Solutions 500/5000 Horizontal Slider spans 34 certified configurations with U-Factors between 0.24 and 0.31 and SHGC values from 0.22 to 0.48. Ranked #1,034 of 1,352 Window families, it carries 0 Most Efficient options.
How does Paradigm Window Solutions 500/5000 Horizontal Slider satisfy Version 7.0 Northern criteria?
Northern qualification on 500/5000 Horizontal Slider relies on EPA Equivalent solar pathways rather than prescriptive <= 0.22 limits, since its best glass sits at U 0.24. Exactly 12 packages pass Northern thresholds with air leakage <= 0.3 cfm/ft2.
How does a 3x5 ft 500/5000 Horizontal Slider window perform under a 40 deg F temperature drop?
Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 500/5000 Horizontal Slider at U 0.24 conducts 144.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.
Who should NOT choose Paradigm Window Solutions 500/5000 Horizontal Slider for a residential project?
Do not specify 500/5000 Horizontal Slider without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 500/5000 Horizontal Slider options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.
How many 500/5000 Horizontal Slider glazing packages pass Southern solar-heat rules?
Warm-climate homeowners have 8 Southern-approved options within 500/5000 Horizontal Slider spanning SHGC down to 0.22. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.
Are all 34 500/5000 Horizontal Slider configurations ENERGY STAR Most Efficient?
ENERGY STAR Most Efficient designation is absent across all 34 500/5000 Horizontal Slider options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.
How do the 25C sunset and pre-1978 Lead RRP rules affect 500/5000 Horizontal Slider?
No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.
How do building inspectors verify 500/5000 Horizontal Slider glass specs on job sites?
Confirm both the paper NFRC label and permanent corner glass etch match line PWS-A-24 and NFRC ID PWS before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Paradigm Window Solutions 500/5000 Horizontal Slider come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)