Skip to main content
Window · Vinyl Frame NFRC TCW · Product Line TCW-K-6

Thompson Creek Window Company — 7800 Double Hung · Double Hung

Thompson Creek Window Company 7800 Double Hung is a Double Hung assembly with a Vinyl frame that reaches a minimum U-Factor of 0.24 across 132 certified glazing configurations covering North-Central, South-Central, Southern. Ranked #1,034 of 1,352 in Window, its thermal floor is 0.04 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.18 to 0.29.

Min U-Factor
0.24
SHGC Range
0.18-0.29
Certified Options
132
Category Standing
#1,034 of 1,352

How does Thompson Creek Window Company 7800 Double Hung compare thermally against Window peers?

Thompson Creek Window Company 7800 Double Hung achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 7800 Double HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing 7800 Double Hung (U 0.24).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

7800 Double Hung Cohort StandingMin U-Factor 0.24 stands at rank #1,034 of 1,352, outperforming 13.2% of peers.Min U-Factor 0.24Rank #1,034 of 1,352 (13.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 7 certified Thompson Creek Window Company series, this Double Hung offers a 0.05 U-Factor adjustment span between 0.29 entry options and 0.24 top-performing glazing. Category standing is #1,034/1,352 (tied with 139 others at 0.24, more insulating than 13.2% of Window lines).

Climate coverage for Thompson Creek Window Company 7800 Double Hung spans North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.18 lowers cooling load.

Data provenance links certification 2025-12-22 and FENSTAR license 2018-09-05 inside EPA Version 7.0 tables. Heat transfer computes to 144.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 132 certified glazing combinations for 7800 Double Hung (NFRC TCW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 84 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 70 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 90 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Burris Windows — TectView AC Horizontal Slider Vinyl 0.24 0.12 137
Hometime Windows & Doors — 1600 Single Hung Vinyl 0.24 0.13 124
United Window & Door Mfg., Inc. — 3810-3910 XO Horizontal Slider Vinyl 0.24 0.18 116
Lindsay Windows — 183 Single Hung Vinyl 0.24 0.14 150
Lindsay Windows — 183 Single Slider Vinyl 0.24 0.14 154

What other certified series does Thompson Creek Window Company produce?

Compare other active Thompson Creek Window Company certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Thompson Creek Window Company 7800 Double Hung appear below.

Where does Thompson Creek Window Company 7800 Double Hung stand thermally among ENERGY STAR Window lines?

Thompson Creek Window Company 7800 Double Hung spans 132 certified configurations with U-Factors between 0.24 and 0.29 and SHGC values from 0.18 to 0.29. Ranked #1,034 of 1,352 Window families, it carries 0 Most Efficient options.

Is 7800 Double Hung approved for Northern Zone heating climates?

Northern Zone certification is absent for 7800 Double Hung (0 qualifying options, min U 0.24). Install this Double-Hung (VSDH) product only within North-Central, South-Central, Southern regions where lower SHGC caps apply.

How do you calculate winter heat conduction for Thompson Creek Window Company 7800 Double Hung?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 7800 Double Hung at U 0.24 conducts 144.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

Who should NOT choose Thompson Creek Window Company 7800 Double Hung for a residential project?

Do not specify 7800 Double Hung without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 7800 Double Hung options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Does 7800 Double Hung meet Southern hot-climate SHGC caps (<= 0.23)?

Exactly 90 7800 Double Hung options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.18 rather than higher 0.29 glass.

How many Thompson Creek Window Company 7800 Double Hung variants earn ENERGY STAR Most Efficient?

ENERGY STAR Most Efficient designation is absent across all 132 7800 Double Hung options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

What federal compliance checks govern 2026 7800 Double Hung window swaps?

Any 7800 Double Hung purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How can homeowners confirm delivered Thompson Creek Window Company 7800 Double Hung units match permits?

Verify NFRC ID TCW and series TCW-K-6 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Thompson Creek Window Company 7800 Double Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros