Window · Vinyl Frame NFRC TCW · Product Line TCW-K-7

Thompson Creek Window Company — 7800 Single Hung · Single Hung

Thompson Creek Window Company 7800 Single Hung is a Single Hung assembly with a Vinyl frame that reaches a minimum U-Factor of 0.23 across 242 certified glazing configurations covering North-Central, South-Central, Southern. Ranked #936 of 1,352 in Window, its thermal floor is 0.03 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.18 to 0.28.

Min U-Factor
0.23
SHGC Range
0.18-0.28
Certified Options
242
Category Standing
#936 of 1,352

How does Thompson Creek Window Company 7800 Single Hung compare thermally against Window peers?

Thompson Creek Window Company 7800 Single Hung achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 7800 Single HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing 7800 Single Hung (U 0.23).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.231460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

7800 Single Hung Cohort StandingMin U-Factor 0.23 stands at rank #936 of 1,352, outperforming 23.6% of peers.Min U-Factor 0.23Rank #936 of 1,352 (23.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), 7800 Single Hung is 0.03 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.23-0.31.

Mapping NFRC SHGC values (0.18 to 0.28) against ENERGY STAR Version 7.0 targets approves North-Central, South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.18 lowers cooling load.

Data provenance links certification 2025-12-22 and FENSTAR license 2018-09-05 inside EPA Version 7.0 tables. Heat transfer computes to 138.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 242 certified glazing combinations for 7800 Single Hung (NFRC TCW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 88 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 108 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 204 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Thompson Creek Window Company produce?

Compare other active Thompson Creek Window Company certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Thompson Creek Window Company 7800 Single Hung appear below.

How well does 7800 Single Hung by Thompson Creek Window Company insulate relative to Window benchmarks?

Across 242 tested NFRC glazing configurations, Thompson Creek Window Company 7800 Single Hung with Vinyl framing and Single-Hung (VSSH) style reaches a 0.23 minimum U-Factor and 0.18-0.28 SHGC band. It places #936 among 1,352 Window series—more insulating than 23.6%.

How does Thompson Creek Window Company 7800 Single Hung satisfy Version 7.0 Northern criteria?

No. Because 7800 Single Hung reaches only 0.23 U-Factor with 0 Northern combinations, it is not approved for ENERGY STAR Northern counties. Specify this Vinyl line strictly across North-Central, South-Central, Southern cooling or mixed markets.

What BTU/hr heat transfer results from 7800 Single Hung's 0.23 minimum U-Factor?

Using NFRC TCW U-Factor 0.23, a 15 sq ft Single-Hung (VSSH) assembly conducts 138.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+6.0 BTU/hr margin).

What homeowner profiles are a poor match for Thompson Creek Window Company 7800 Single Hung?

Do not specify 7800 Single Hung without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 7800 Single Hung options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Can you install Thompson Creek Window Company 7800 Single Hung in Southern or South-Central zones?

Yes. 204 Southern-certified options inside Thompson Creek Window Company 7800 Single Hung satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.28 SHGC on west-facing glass to avoid excess afternoon solar gain.

Does 7800 Single Hung carry EPA Most Efficient certification across its lineup?

No. Zero of the 242 configurations in Thompson Creek Window Company 7800 Single Hung hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.

Do 2026 7800 Single Hung installations qualify for IRS Section 25C tax credits?

Any 7800 Single Hung purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

Where are NFRC and IGCC identification marks located on 7800 Single Hung?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code TCW and product line TCW-K-7, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Thompson Creek Window Company 7800 Single Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros