Skip to main content
Window · Vinyl Frame NFRC ANL · Product Line ANL-A-19

Anlin Industries — Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Horizontal Slider · Single Slider

Across 14 Anlin Industries certified families, Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Horizontal Slider supplies 230 Single Slider configurations starting at 0.23 U-Factor and 0.13 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.52 SHGC. Its thermal floor ranks #936 of 1,352 category entries—0.03 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.23
SHGC Range
0.13-0.52
Certified Options
230
Category Standing
#936 of 1,352

How does Anlin Industries Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Horizontal Slider compare thermally against Window peers?

Anlin Industries Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Horizontal Slider achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Horizontal SliderHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Horizontal Slider (U 0.23).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.231460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Horizontal Slider Cohort StandingMin U-Factor 0.23 stands at rank #936 of 1,352, outperforming 23.6% of peers.Min U-Factor 0.23Rank #936 of 1,352 (23.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Anlin Industries Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Horizontal Slider standing at #936 of 1,352 certified Window product series, tied with 97 others at 0.23, more insulating than 23.6% of Window lines. Comparing Vinyl profiles alone (median 0.19) shows +0.04 before selecting Low-E tiers.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). Although its 0.23 floor sits above the 0.22 prescriptive Northern ceiling, 12 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Data provenance links certification 2026-09-08 and FENSTAR license 2017-12-11 inside EPA Version 7.0 tables. Heat transfer computes to 138.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 230 certified glazing combinations for Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Horizontal Slider (NFRC ANL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 12 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 48 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 134 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 206 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Anlin Industries produce?

Compare other active Anlin Industries certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Anlin Industries Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Horizontal Slider appear below.

How efficient is Anlin Industries Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Horizontal Slider compared with peer Window models?

Anlin Industries Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Horizontal Slider spans 230 certified configurations with U-Factors between 0.23 and 0.32 and SHGC values from 0.13 to 0.52. Ranked #936 of 1,352 Window families, it carries 0 Most Efficient options.

Does Anlin Industries Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Horizontal Slider qualify for the ENERGY STAR Northern Zone?

Because Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Horizontal Slider starts at 0.23 U-Factor, it exceeds the 0.22 prescriptive ceiling. Instead, 12 Northern packages qualify through EPA Equivalent Energy Performance rules pairing U 0.23-0.26 with higher SHGC (>= 0.35 or >= 0.40).

How does a 3x5 ft Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Horizontal Slider window perform under a 40 deg F temperature drop?

Using NFRC ANL U-Factor 0.23, a 15 sq ft Horizontal Slider (HSOX) assembly conducts 138.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+6.0 BTU/hr margin).

When should a buyer skip Anlin Industries Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Horizontal Slider and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Horizontal Slider options exceeding U 0.22. Additionally, do not order Horizontal Slider (HSOX) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

What Southern ENERGY STAR v7.0 options exist in Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Horizontal Slider?

Warm-climate homeowners have 206 Southern-approved options within Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Horizontal Slider spanning SHGC down to 0.13. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Does Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Horizontal Slider carry EPA Most Efficient certification across its lineup?

All 230 Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Horizontal Slider listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

What 2026 federal tax credit and Lead RRP rules apply to Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Horizontal Slider?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How do building inspectors verify Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Horizontal Slider glass specs on job sites?

Inspectors match the temporary NFRC sticker (U 0.23-0.32, SHGC 0.13-0.52) against permit drawings for line ANL-A-19. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Anlin Industries Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Horizontal Slider come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros