Anlin Industries — Coronado/Monte Verde/Bayview/Extreme Fixed Casement · Picture Window
Anlin Industries engineered the Coronado/Monte Verde/Bayview/Extreme Fixed Casement Picture Window line for Northern, North-Central, South-Central, Southern, certifying 462 glass-spacer combinations from 0.22 to 0.32 U-Factor and 0.12 to 0.47 SHGC. Relative to other Vinyl models tracked under NFRC ANL, its minimum U-Factor is 0.03 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.22
- SHGC Range
- 0.12-0.47
- Certified Options
- 462
- Category Standing
- #831 of 1,352
How does Anlin Industries Coronado/Monte Verde/Bayview/Extreme Fixed Casement compare thermally against Window peers?
Anlin Industries Coronado/Monte Verde/Bayview/Extreme Fixed Casement achieves a 0.22 thermal floor across Window lines, placing #831 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Anlin Industries Coronado/Monte Verde/Bayview/Extreme Fixed Casement at rank #831 of 1,352 (tied with 104 others at 0.22, more insulating than 30.8% of Window lines; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.12-0.47 band.
Mapping NFRC SHGC values (0.12 to 0.47) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 14 configurations meet ENERGY STAR Most Efficient criteria while 28 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Lifecycle documentation anchors ANL to 2024-02-14 certification (FENSTAR issued 2017-12-11). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 132.0 BTU/hr conductive loss (equal to the 0.22 Northern floor).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 462 certified glazing combinations for Coronado/Monte Verde/Bayview/Extreme Fixed Casement (NFRC ANL) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Certified | <= 0.22 | >= 0.17 | 28 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 182 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 244 packages (0 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 383 packages (14 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Quaker Window Products — V100 Fixed | Vinyl | 0.22 | 0.15 | 470 |
| YKK AP America, Inc. — Style View/Style View NT/Style View Classic Picture | Vinyl | 0.22 | 0.19 | 471 |
| Soft-Lite, LLC — Classic Plus DH10P Double Hung | Vinyl | 0.22 | 0.15 | 477 |
| YKK AP America, Inc. — Style View/Style View NT/Style View Classic Geometric | Vinyl | 0.22 | 0.20 | 401 |
| ESWindows LLC — ES-V150 Picture Window | Vinyl | 0.22 | 0.15 | 338 |
What other certified series does Anlin Industries produce?
Compare other active Anlin Industries certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
Catalina/Del Mar/Extreme Horizontal Sliding Window
U-Factor 0.23–0.32 · 259 certified options.
Catalina/Del Mar/Extreme Single Hung Window
U-Factor 0.23–0.32 · 259 certified options.
Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Horizontal Slider
U-Factor 0.23–0.32 · 230 certified options.
Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Single Hung
U-Factor 0.23–0.32 · 230 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Anlin Industries Coronado/Monte Verde/Bayview/Extreme Fixed Casement appear below.
Where does Anlin Industries Coronado/Monte Verde/Bayview/Extreme Fixed Casement stand thermally among ENERGY STAR Window lines?
Anlin Industries Coronado/Monte Verde/Bayview/Extreme Fixed Casement spans 462 certified configurations with U-Factors between 0.22 and 0.32 and SHGC values from 0.12 to 0.47. Ranked #831 of 1,352 Window families, it carries 14 Most Efficient options.
Which glazing options in Anlin Industries Coronado/Monte Verde/Bayview/Extreme Fixed Casement meet Northern climate limits?
Yes. 28 packages in Anlin Industries Coronado/Monte Verde/Bayview/Extreme Fixed Casement clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.
How does a 3x5 ft Coronado/Monte Verde/Bayview/Extreme Fixed Casement window perform under a 40 deg F temperature drop?
Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Coronado/Monte Verde/Bayview/Extreme Fixed Casement at U 0.22 conducts 132.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.
What are the practical limitations of specifying Coronado/Monte Verde/Bayview/Extreme Fixed Casement?
Do not specify Coronado/Monte Verde/Bayview/Extreme Fixed Casement without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Coronado/Monte Verde/Bayview/Extreme Fixed Casement options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.
Does Coronado/Monte Verde/Bayview/Extreme Fixed Casement meet Southern hot-climate SHGC caps (<= 0.23)?
Yes. 383 Southern-certified options inside Anlin Industries Coronado/Monte Verde/Bayview/Extreme Fixed Casement satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.47 SHGC on west-facing glass to avoid excess afternoon solar gain.
Which package tier in Coronado/Monte Verde/Bayview/Extreme Fixed Casement holds Most Efficient recognition?
Within Coronado/Monte Verde/Bayview/Extreme Fixed Casement, 3.0% (14 of 462) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.
What 2026 federal tax credit and Lead RRP rules apply to Coronado/Monte Verde/Bayview/Extreme Fixed Casement?
Any Coronado/Monte Verde/Bayview/Extreme Fixed Casement purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.
Where are NFRC and IGCC identification marks located on Coronado/Monte Verde/Bayview/Extreme Fixed Casement?
Match the NFRC thermal sticker for code ANL and line ANL-A-11 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Anlin Industries Coronado/Monte Verde/Bayview/Extreme Fixed Casement come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)