Anlin Industries — Coronado Double Hung · Double Hung
Across 14 Anlin Industries certified families, Coronado Double Hung supplies 321 Double Hung configurations starting at 0.24 U-Factor and 0.12 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.47 SHGC. Its thermal floor ranks #1,034 of 1,352 category entries—0.04 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.24
- SHGC Range
- 0.12-0.47
- Certified Options
- 321
- Category Standing
- #1,034 of 1,352
How does Anlin Industries Coronado Double Hung compare thermally against Window peers?
Anlin Industries Coronado Double Hung achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Glazing breadth across Coronado Double Hung spans 321 NFRC test records (ANL), ranking #1,034 of 1,352 Window families (tied with 139 others at 0.24, more insulating than 13.2% of Window lines). Its 0.24 thermal floor compares at +0.05 against the Vinyl median (0.19).
Regional qualification covers Northern, North-Central, South-Central, Southern. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 7 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).
Registry history records EPA FENSTAR licensing on 2017-12-11 and v7.0 data certification on 2023-12-19. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.24 conducts 144.0 BTU/hr (+12.0 BTU/hr vs the 0.22 ceiling).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 321 certified glazing combinations for Coronado Double Hung (NFRC ANL) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Equiv. Path | <= 0.22 | >= 0.17 | 7 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 58 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 142 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 295 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| EnergyWall Window — 3030 Slider | Vinyl | 0.24 | 0.19 | 373 |
| Polaris Windows and Doors — 3030 Slider | Vinyl | 0.24 | 0.19 | 373 |
| Westlake Royal Windows LLC — 250 Single Hung | Vinyl | 0.24 | 0.17 | 376 |
| MGM Industries — 6010 Horizontal Slider | Vinyl | 0.24 | 0.13 | 382 |
| Thompson Creek Window Company — 7800 Single Slider | Vinyl | 0.24 | 0.17 | 256 |
What other certified series does Anlin Industries produce?
Compare other active Anlin Industries certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
Coronado/Monte Verde/Bayview/Extreme Fixed Casement
U-Factor 0.22–0.32 · 462 certified options.
Catalina/Del Mar/Extreme Horizontal Sliding Window
U-Factor 0.23–0.32 · 259 certified options.
Catalina/Del Mar/Extreme Single Hung Window
U-Factor 0.23–0.32 · 259 certified options.
Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Horizontal Slider
U-Factor 0.23–0.32 · 230 certified options.
Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Single Hung
U-Factor 0.23–0.32 · 230 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Anlin Industries Coronado Double Hung appear below.
How efficient is Anlin Industries Coronado Double Hung compared with peer Window models?
Anlin Industries Coronado Double Hung spans 321 certified configurations with U-Factors between 0.24 and 0.32 and SHGC values from 0.12 to 0.47. Ranked #1,034 of 1,352 Window families, it carries 0 Most Efficient options.
Which glazing options in Anlin Industries Coronado Double Hung meet Northern climate limits?
Northern qualification on Coronado Double Hung relies on EPA Equivalent solar pathways rather than prescriptive <= 0.22 limits, since its best glass sits at U 0.24. Exactly 7 packages pass Northern thresholds with air leakage <= 0.3 cfm/ft2.
How does a 3x5 ft Coronado Double Hung window perform under a 40 deg F temperature drop?
At U 0.24, a standard 3x5 ft (15 sq ft) Coronado Double Hung opening transfers 144.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +12.0 BTU/hr difference.
When should a buyer skip Anlin Industries Coronado Double Hung and compare alternatives?
Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Coronado Double Hung options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.
What Southern ENERGY STAR v7.0 options exist in Coronado Double Hung?
Across Northern, North-Central, South-Central, Southern, 295 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Anlin Industries Coronado Double Hung, while total line SHGC reaches 0.47 in colder packages.
How many Anlin Industries Coronado Double Hung variants earn ENERGY STAR Most Efficient?
ENERGY STAR Most Efficient designation is absent across all 321 Coronado Double Hung options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.
How do the 25C sunset and pre-1978 Lead RRP rules affect Coronado Double Hung?
No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.
Where are NFRC and IGCC identification marks located on Coronado Double Hung?
Leave the temporary NFRC label intact until inspection to confirm manufacturer code ANL and product line ANL-A-6, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Anlin Industries Coronado Double Hung come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)