Skip to main content
Window · Vinyl Frame NFRC ANL · Product Line ANL-A-20

Anlin Industries — Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Single Hung · Single Hung

Across 14 Anlin Industries certified families, Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Single Hung supplies 230 Single Hung configurations starting at 0.23 U-Factor and 0.13 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.52 SHGC. Its thermal floor ranks #936 of 1,352 category entries—0.03 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.23
SHGC Range
0.13-0.52
Certified Options
230
Category Standing
#936 of 1,352

How does Anlin Industries Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Single Hung compare thermally against Window peers?

Anlin Industries Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Single Hung achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Single HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Single Hung (U 0.23).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.231460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Single Hung Cohort StandingMin U-Factor 0.23 stands at rank #936 of 1,352, outperforming 23.6% of peers.Min U-Factor 0.23Rank #936 of 1,352 (23.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Anlin Industries Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Single Hung standing at #936 of 1,352 certified Window product series, tied with 97 others at 0.23, more insulating than 23.6% of Window lines. Comparing Vinyl profiles alone (median 0.19) shows +0.04 before selecting Low-E tiers.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). Although its 0.23 floor sits above the 0.22 prescriptive Northern ceiling, 12 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Registry history records EPA FENSTAR licensing on 2017-12-11 and v7.0 data certification on 2026-09-08. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.23 conducts 138.0 BTU/hr (+6.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 230 certified glazing combinations for Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Single Hung (NFRC ANL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 12 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 48 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 128 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 206 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Anlin Industries produce?

Compare other active Anlin Industries certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Anlin Industries Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Single Hung appear below.

Where does Anlin Industries Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Single Hung stand thermally among ENERGY STAR Window lines?

Across 230 tested NFRC glazing configurations, Anlin Industries Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Single Hung with Vinyl framing and Single-Hung (VSSH) style reaches a 0.23 minimum U-Factor and 0.13-0.52 SHGC band. It places #936 among 1,352 Window series—more insulating than 23.6%.

How does Anlin Industries Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Single Hung satisfy Version 7.0 Northern criteria?

Prescriptive Northern approval ends at U <= 0.22, above Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Single Hung's 0.23 minimum. However, 12 Northern packages pass EPA Equivalent compliance by pairing higher solar gain (SHGC >= 0.35 or 0.40) with <= 0.3 cfm/ft2 air leakage.

How do you calculate winter heat conduction for Anlin Industries Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Single Hung?

Using NFRC ANL U-Factor 0.23, a 15 sq ft Single-Hung (VSSH) assembly conducts 138.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+6.0 BTU/hr margin).

Which situations make Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Single Hung the wrong window or door choice?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Single Hung options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

How many Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Single Hung glazing packages pass Southern solar-heat rules?

Warm-climate homeowners have 206 Southern-approved options within Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Single Hung spanning SHGC down to 0.13. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

How many Anlin Industries Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Single Hung variants earn ENERGY STAR Most Efficient?

Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Single Hung holds zero Most Efficient entries across its 230 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

What federal compliance checks govern 2026 Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Single Hung window swaps?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Anlin Industries upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How do building inspectors verify Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Single Hung glass specs on job sites?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code ANL and product line ANL-A-20, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Anlin Industries Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Single Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)