Skip to main content
Window · Vinyl Frame NFRC PEL · Product Line PEL-N-107

Pella Corporation — 150 Series Single Hung · Single Hung

Pella Corporation 150 Series Single Hung is a Single Hung assembly with a Vinyl frame that reaches a minimum U-Factor of 0.24 across 103 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #1,034 of 1,352 in Window, its thermal floor is 0.04 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.20 to 0.52.

Min U-Factor
0.24
SHGC Range
0.20-0.52
Certified Options
103
Category Standing
#1,034 of 1,352

How does Pella Corporation 150 Series Single Hung compare thermally against Window peers?

Pella Corporation 150 Series Single Hung achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 150 Series Single HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing 150 Series Single Hung (U 0.24).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

150 Series Single Hung Cohort StandingMin U-Factor 0.24 stands at rank #1,034 of 1,352, outperforming 13.2% of peers.Min U-Factor 0.24Rank #1,034 of 1,352 (13.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), 150 Series Single Hung is 0.04 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.24-0.32.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 21 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Lifecycle documentation anchors PEL to 2024-05-02 certification (FENSTAR issued 2018-02-20). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 144.0 BTU/hr conductive loss (+9.1% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 103 certified glazing combinations for 150 Series Single Hung (NFRC PEL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 21 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 37 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 38 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 66 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Pella Corporation produce?

Compare other active Pella Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Pella Corporation 150 Series Single Hung appear below.

What U-Factor and SHGC range does Pella Corporation 150 Series Single Hung achieve?

Across 103 tested NFRC glazing configurations, Pella Corporation 150 Series Single Hung with Vinyl framing and Single-Hung (VSSH) style reaches a 0.24 minimum U-Factor and 0.20-0.52 SHGC band. It places #1,034 among 1,352 Window series—more insulating than 13.2%.

Which glazing options in Pella Corporation 150 Series Single Hung meet Northern climate limits?

With a 0.24 minimum U-Factor, Pella Corporation 150 Series Single Hung cannot satisfy prescriptive <= 0.22 Northern targets, yet 21 high-SHGC packages meet EPA's solar-gain Equivalent route for cold northern homes.

How much winter heat loss does 150 Series Single Hung conduct across a 15 sq ft opening?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 150 Series Single Hung at U 0.24 conducts 144.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

What homeowner profiles are a poor match for Pella Corporation 150 Series Single Hung?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 150 Series Single Hung options exceeding U 0.22. Additionally, do not order Single-Hung (VSSH) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

How many 150 Series Single Hung glazing packages pass Southern solar-heat rules?

Yes, 150 Series Single Hung holds 66 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.20 SHGC in cooling climates.

How many Pella Corporation 150 Series Single Hung variants earn ENERGY STAR Most Efficient?

Zero glazing builds inside 150 Series Single Hung's 103 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

How do the 25C sunset and pre-1978 Lead RRP rules affect 150 Series Single Hung?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How do building inspectors verify 150 Series Single Hung glass specs on job sites?

Confirm both the paper NFRC label and permanent corner glass etch match line PEL-N-107 and NFRC ID PEL before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Pella Corporation 150 Series Single Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros