Skip to main content
Window · Vinyl Frame NFRC EWG · Product Line EWG-K-7 ENERGY STAR Most Efficient Eligible

Earthwise Group, LLC — 140.148 / 143.191 / 143.148 Awning · Awning (Projected)

EPA ENERGY STAR Version 7.0 certifies 289 variants inside Earthwise Group, LLC 140.148 / 143.191 / 143.148 Awning, combining Vinyl frame construction with U-Factors spanning 0.21 to 0.32 and SHGC 0.12 to 0.46. Qualifying for Northern, North-Central, South-Central, Southern, this Awning, Projected family places #742 of 1,352 among 1,352 Window families and posts 0.02 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

Min U-Factor
0.21
SHGC Range
0.12-0.46
Certified Options
289
Category Standing
#742 of 1,352

How does Earthwise Group, LLC 140.148 / 143.191 / 143.148 Awning compare thermally against Window peers?

Earthwise Group, LLC 140.148 / 143.191 / 143.148 Awning achieves a 0.21 thermal floor across Window lines, placing #742 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 140.148 / 143.191 / 143.148 AwningHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing 140.148 / 143.191 / 143.148 Awning (U 0.21).249<=0.153140.16-0.182670.19-0.21This model: U 0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

140.148 / 143.191 / 143.148 Awning Cohort StandingMin U-Factor 0.21 stands at rank #742 of 1,352, outperforming 38.6% of peers.Min U-Factor 0.21Rank #742 of 1,352 (38.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Earthwise Group, LLC 140.148 / 143.191 / 143.148 Awning at rank #742 of 1,352 (tied with 88 others at 0.21, more insulating than 38.6% of Window lines; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.12-0.46 band.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 6 configurations meet ENERGY STAR Most Efficient criteria while 48 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2023-12-21 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 126.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 289 certified glazing combinations for 140.148 / 143.191 / 143.148 Awning (NFRC EWG) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 48 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 84 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 122 packages (0 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 207 packages (6 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Earthwise Group, LLC produce?

Compare other active Earthwise Group, LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Earthwise Group, LLC 140.148 / 143.191 / 143.148 Awning appear below.

How well does 140.148 / 143.191 / 143.148 Awning by Earthwise Group, LLC insulate relative to Window benchmarks?

Earthwise Group, LLC 140.148 / 143.191 / 143.148 Awning spans 289 certified configurations with U-Factors between 0.21 and 0.32 and SHGC values from 0.12 to 0.46. Ranked #742 of 1,352 Window families, it carries 6 Most Efficient options.

Which glazing options in Earthwise Group, LLC 140.148 / 143.191 / 143.148 Awning meet Northern climate limits?

Earthwise Group, LLC 140.148 / 143.191 / 143.148 Awning supplies 48 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.32, so inspect the NFRC order sheet before purchase.

How much winter heat loss does 140.148 / 143.191 / 143.148 Awning conduct across a 15 sq ft opening?

At U 0.21, a standard 3x5 ft (15 sq ft) 140.148 / 143.191 / 143.148 Awning opening transfers 126.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -6.0 BTU/hr difference.

Who should NOT choose Earthwise Group, LLC 140.148 / 143.191 / 143.148 Awning for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 140.148 / 143.191 / 143.148 Awning options exceeding U 0.22. Additionally, do not order Projected Awning (PRAW) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

What Southern ENERGY STAR v7.0 options exist in 140.148 / 143.191 / 143.148 Awning?

Yes, 140.148 / 143.191 / 143.148 Awning holds 207 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.12 SHGC in cooling climates.

How many Earthwise Group, LLC 140.148 / 143.191 / 143.148 Awning variants earn ENERGY STAR Most Efficient?

Not every package qualifies: 6 of 289 140.148 / 143.191 / 143.148 Awning glazing builds earn Most Efficient recognition (2.1%), while other variants sit on the standard Version 7.0 tier.

What federal compliance checks govern 2026 140.148 / 143.191 / 143.148 Awning window swaps?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How can homeowners confirm delivered Earthwise Group, LLC 140.148 / 143.191 / 143.148 Awning units match permits?

Confirm both the paper NFRC label and permanent corner glass etch match line EWG-K-7 and NFRC ID EWG before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Earthwise Group, LLC 140.148 / 143.191 / 143.148 Awning come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros