Skip to main content
Door · Steel / Wood Frame NFRC STN · Product Line STN-K-2

Masonite International Corporation — Masonite Steel Steel Edge Steel Door · Swinging Entry Door (Single)

With a minimum U-Factor of 0.16—-0.05 compared against the 0.21 Door median—Masonite International Corporation Masonite Steel Steel Edge Steel Door spans 66,438 tested options across Northern, North-Central, South-Central, Southern up to 0.28 U-Factor. Carrying NFRC CPD code STN, the Steel / Wood assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.01 and 0.29.

Min U-Factor
0.16
SHGC Range
0.01-0.29
Certified Options
66,438
Category Standing
#29 of 268

How does Masonite International Corporation Masonite Steel Steel Edge Steel Door compare thermally against Door peers?

Masonite International Corporation Masonite Steel Steel Edge Steel Door achieves a 0.16 thermal floor across Door lines, placing #29 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. Masonite Steel Steel Edge Steel DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing Masonite Steel Steel Edge Steel Door (U 0.16).28<=0.15650.16-0.18This model: U 0.16510.19-0.21710.22-0.24430.25-0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

Masonite Steel Steel Edge Steel Door Cohort StandingMin U-Factor 0.16 stands at rank #29 of 268, outperforming 79.9% of peers.Min U-Factor 0.16Rank #29 of 268 (79.9% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 13 certified Masonite International Corporation series, this Swinging Entry Door, Single offers a 0.12 U-Factor adjustment span between 0.28 entry options and 0.16 top-performing glazing. Category standing is #29/268 (tied with 25 others at 0.16, more insulating than 79.9% of Door lines, top 20.1%).

Climate coverage for Masonite International Corporation Masonite Steel Steel Edge Steel Door spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 51,675 combinations qualify in the Northern Zone alongside 66,201 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 96.0 BTU/hr (-27.3% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2024-02-29.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 66,438 certified glazing combinations for Masonite Steel Steel Edge Steel Door (NFRC STN) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 51,675 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 51,675 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 66,201 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 66,201 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Specialty Wholesale Supply — Metal Edge/Steel Entry Door Steel / Wood 0.16 0.01 64,485
Marvin — Ultimate Sliding Glass Door G2 Wood 0.16 0.09 31,210
Quaker Window Products — V300 Inswing Door Vinyl 0.16 0.08 17,041
Quaker Window Products — V300/V600 Outswing Door Vinyl 0.16 0.08 16,974
Wincore Window Company, LLC — Fiberglass Entry Door Composite / Steel / Wood 0.16 0.00 11,717

What other certified series does Masonite International Corporation produce?

Compare other active Masonite International Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Masonite International Corporation Masonite Steel Steel Edge Steel Door appear below.

What thermal performance numbers separate Masonite International Corporation Masonite Steel Steel Edge Steel Door from peers?

Masonite International Corporation Masonite Steel Steel Edge Steel Door spans 66,438 certified configurations with U-Factors between 0.16 and 0.28 and SHGC values from 0.01 to 0.29. Ranked #29 of 268 Door families, it carries 0 Most Efficient options.

How does Masonite International Corporation Masonite Steel Steel Edge Steel Door satisfy Version 7.0 Northern criteria?

Prescriptive Northern compliance covers 51,675 Masonite Steel Steel Edge Steel Door packages (U floor 0.16, SHGC >= 0.17). Because the complete series stretches up to U 0.28, specify the cold-climate glass code explicitly.

What BTU/hr heat transfer results from Masonite Steel Steel Edge Steel Door's 0.16 minimum U-Factor?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Masonite Steel Steel Edge Steel Door at U 0.16 conducts 96.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

What are the practical limitations of specifying Masonite Steel Steel Edge Steel Door?

Do not specify Masonite Steel Steel Edge Steel Door without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Masonite Steel Steel Edge Steel Door options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Is Masonite Steel Steel Edge Steel Door suitable for sunbelt cooling-dominated homes?

Exactly 66,201 Masonite Steel Steel Edge Steel Door options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.01 rather than higher 0.29 glass.

Which package tier in Masonite Steel Steel Edge Steel Door holds Most Efficient recognition?

Zero glazing builds inside Masonite Steel Steel Edge Steel Door's 66,438 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

What 2026 federal tax credit and Lead RRP rules apply to Masonite Steel Steel Edge Steel Door?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Masonite International Corporation upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

What permanent glass etch marks verify Masonite Steel Steel Edge Steel Door after sticker removal?

Inspectors match the temporary NFRC sticker (U 0.16-0.28, SHGC 0.01-0.29) against permit drawings for line STN-K-2. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Masonite International Corporation Masonite Steel Steel Edge Steel Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros