Masonite International Corporation — Masonite Fiberglass Skin Sidelite · Sidelite
Across 13 Masonite International Corporation certified families, Masonite Fiberglass Skin Sidelite supplies 321,052 Sidelite configurations starting at 0.15 U-Factor and 0.01 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.28 U-Factor and 0.19 SHGC. Its thermal floor ranks #136 of 1,352 category entries—0.05 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.15
- SHGC Range
- 0.01-0.19
- Certified Options
- 321,052
- Category Standing
- #136 of 1,352
How does Masonite International Corporation Masonite Fiberglass Skin Sidelite compare thermally against Window peers?
Masonite International Corporation Masonite Fiberglass Skin Sidelite achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Masonite International Corporation Masonite Fiberglass Skin Sidelite at rank #136 of 1,352 (tied with 113 others at 0.15, more insulating than 81.6% of Window lines, top 18.4%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.01-0.19 band.
Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 302,557 combinations qualify in the Northern Zone alongside 321,052 Southern configurations matching hot-climate SHGC <= 0.23 caps.
Registry history records EPA FENSTAR licensing on 2018-01-10 and v7.0 data certification on 2024-02-29. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.15 conducts 90.0 BTU/hr (-42.0 BTU/hr vs the 0.22 ceiling).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 321,052 certified glazing combinations for Masonite Fiberglass Skin Sidelite (NFRC STN) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Certified | <= 0.22 | >= 0.17 | 302,557 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 302,557 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 321,052 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 321,052 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Pella Corporation — Pella Entry Doors - Fiberglass Skin Sidelite | Wood | 0.15 | 0.01 | 319,127 |
| Specialty Wholesale Supply — Fiberglass Sidelite | Wood | 0.15 | 0.01 | 319,127 |
| Kohltech International, Ltd. — Fiberglass Sidelite | Wood | 0.15 | 0.01 | 394,477 |
| Kohltech International, Ltd. — Steel Sidelite | Wood | 0.15 | 0.01 | 84,427 |
| Specialty Wholesale Supply — Wood Edge Steel Sidelite | Wood | 0.15 | 0.01 | 82,347 |
What other certified series does Masonite International Corporation produce?
Compare other active Masonite International Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
Masonite Steel Wood Edge Steel Door
U-Factor 0.13–0.28 · 77,538 certified options.
Masonite Steel Wood Edge Steel Door
U-Factor 0.13–0.28 · 77,544 certified options.
Fiberglass LXF Door
U-Factor 0.14–0.28 · 260 certified options.
Masonite Fiberglass Skin Door
U-Factor 0.15–0.28 · 244,260 certified options.
Masonite Fiberglass Skin Door
U-Factor 0.15–0.28 · 244,193 certified options.
Masonite Fiberglass Skin Sidelite
U-Factor 0.15–0.28 · 321,052 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Masonite International Corporation Masonite Fiberglass Skin Sidelite appear below.
Where does Masonite International Corporation Masonite Fiberglass Skin Sidelite stand thermally among ENERGY STAR Window lines?
Testing puts Masonite International Corporation Masonite Fiberglass Skin Sidelite at rank #136 of 1,352 Window entries with U 0.15 to 0.28 across 321,052 configurations. Solar heat gain ranges between 0.01 and 0.19 across Northern, North-Central, South-Central, Southern.
Can homeowners install Masonite Fiberglass Skin Sidelite in cold Northern ENERGY STAR counties?
Yes, 302,557 packages satisfy Northern ENERGY STAR Version 7.0 rules in Masonite Fiberglass Skin Sidelite. Pairing multi-pane insulation down to 0.15 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.
What conductive BTU/hr difference separates Masonite Fiberglass Skin Sidelite from the 0.22 Northern rule?
Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.15 U-Factor yields 90.0 BTU/hr conductive transfer (-31.8% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.
When should a buyer skip Masonite International Corporation Masonite Fiberglass Skin Sidelite and compare alternatives?
Cold-climate owners needing prescriptive U <= 0.22 should pass on Masonite Fiberglass Skin Sidelite options exceeding U 0.22. Additionally, do not order Fixed Sidelite (FXSL) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).
How many Masonite Fiberglass Skin Sidelite glazing packages pass Southern solar-heat rules?
Yes, Masonite Fiberglass Skin Sidelite holds 321,052 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.01 SHGC in cooling climates.
Are all 321,052 Masonite Fiberglass Skin Sidelite configurations ENERGY STAR Most Efficient?
Zero glazing builds inside Masonite Fiberglass Skin Sidelite's 321,052 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.
Can homeowners claim Form 5695 credits on Masonite International Corporation Masonite Fiberglass Skin Sidelite in 2026?
Tax rules ended Section 25C on December 31, 2025, shifting 2026 Masonite International Corporation upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.
How do building inspectors verify Masonite Fiberglass Skin Sidelite glass specs on job sites?
Verify NFRC ID STN and series STN-K-30 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Masonite International Corporation Masonite Fiberglass Skin Sidelite come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)