Skip to main content
Door · Fiberglass Frame NFRC ALP · Product Line ALP-M-29 ENERGY STAR Most Efficient Eligible

Alpen HPP, LLC dba Alpen High Performance Products — Zenith Grandline Sliding Glass Door · Sliding Patio Door

Positioning #11/268 in certified Door, Alpen HPP, LLC dba Alpen High Performance Products Zenith Grandline Sliding Glass Door pairs Fiberglass frame construction with 217 glazing options rated between 0.11 and 0.40 SHGC across Northern, North-Central, South-Central, Southern. Across 11 certified Alpen HPP, LLC dba Alpen High Performance Products product families, its thermal resistance spans 0.14 to 0.27 U-Factor and the line includes 191 ENERGY STAR Most Efficient packages (88.0% of line).

Min U-Factor
0.14
SHGC Range
0.11-0.40
Certified Options
217
Category Standing
#11 of 268

How does Alpen HPP, LLC dba Alpen High Performance Products Zenith Grandline Sliding Glass Door compare thermally against Door peers?

Alpen HPP, LLC dba Alpen High Performance Products Zenith Grandline Sliding Glass Door achieves a 0.14 thermal floor across Door lines, placing #11 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. Zenith Grandline Sliding Glass DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin <=0.15 containing Zenith Grandline Sliding Glass Door (U 0.14).28<=0.15This model: U 0.14650.16-0.18510.19-0.21710.22-0.24430.25-0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

Zenith Grandline Sliding Glass Door Cohort StandingMin U-Factor 0.14 stands at rank #11 of 268, outperforming 93.7% of peers.Min U-Factor 0.14Rank #11 of 268 (93.7% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 11 certified Alpen HPP, LLC dba Alpen High Performance Products series, this Sliding Patio Door offers a 0.13 U-Factor adjustment span between 0.27 entry options and 0.14 top-performing glazing. Category standing is #11/268 (tied with 6 others at 0.14, more insulating than 93.7% of Door lines, top 6.3%).

Mapping NFRC SHGC values (0.11 to 0.40) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 191 configurations meet ENERGY STAR Most Efficient criteria while 215 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 84.0 BTU/hr (-36.4% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2023-08-28 and cert timestamp 2025-07-24.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 217 certified glazing combinations for Zenith Grandline Sliding Glass Door (NFRC ALP) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 215 packages (109 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 215 packages (179 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 102 packages (80 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 102 packages (92 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.14 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Alpen HPP, LLC dba Alpen High Performance Products produce?

Compare other active Alpen HPP, LLC dba Alpen High Performance Products certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Alpen HPP, LLC dba Alpen High Performance Products Zenith Grandline Sliding Glass Door appear below.

How well does Zenith Grandline Sliding Glass Door by Alpen HPP, LLC dba Alpen High Performance Products insulate relative to Door benchmarks?

EPA ENERGY STAR v7.0 records 217 configurations for Alpen HPP, LLC dba Alpen High Performance Products Zenith Grandline Sliding Glass Door covering Northern, North-Central, South-Central, Southern, dropping down to U 0.14 versus a 0.21 Door median. Only 191 options earn Most Efficient status.

How does Alpen HPP, LLC dba Alpen High Performance Products Zenith Grandline Sliding Glass Door satisfy Version 7.0 Northern criteria?

Yes, 215 packages satisfy Northern ENERGY STAR Version 7.0 rules in Zenith Grandline Sliding Glass Door. Pairing multi-pane insulation down to 0.14 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

How does a 3x5 ft Zenith Grandline Sliding Glass Door window perform under a 40 deg F temperature drop?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.14 U-Factor yields 84.0 BTU/hr conductive transfer (-36.4% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

When should a buyer skip Alpen HPP, LLC dba Alpen High Performance Products Zenith Grandline Sliding Glass Door and compare alternatives?

Skip Zenith Grandline Sliding Glass Door if local historic preservation boards prohibit Fiberglass profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Zenith Grandline Sliding Glass Door options exceeding U 0.22.

What Southern ENERGY STAR v7.0 options exist in Zenith Grandline Sliding Glass Door?

Across Northern, North-Central, South-Central, Southern, 102 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Alpen HPP, LLC dba Alpen High Performance Products Zenith Grandline Sliding Glass Door, while total line SHGC reaches 0.40 in colder packages.

Are all 217 Zenith Grandline Sliding Glass Door configurations ENERGY STAR Most Efficient?

Not every package qualifies: 191 of 217 Zenith Grandline Sliding Glass Door glazing builds earn Most Efficient recognition (88.0%), while other variants sit on the standard Version 7.0 tier.

How do the 25C sunset and pre-1978 Lead RRP rules affect Zenith Grandline Sliding Glass Door?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How can homeowners confirm delivered Alpen HPP, LLC dba Alpen High Performance Products Zenith Grandline Sliding Glass Door units match permits?

Inspectors match the temporary NFRC sticker (U 0.14-0.27, SHGC 0.11-0.40) against permit drawings for line ALP-M-29. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Alpen HPP, LLC dba Alpen High Performance Products Zenith Grandline Sliding Glass Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros