Skip to main content
Door · Wood Frame NFRC WIN · Product Line WIN-N-130

Windsor Windows and Doors — Pinnacle Clad Outswing Door Stationary Panel · Swinging Entry Door (Single)

Windsor Windows and Doors Pinnacle Clad Outswing Door Stationary Panel is a Swinging Entry Door, Single assembly with a Wood frame that reaches a minimum U-Factor of 0.24 across 139 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #199 of 268 in Door, its thermal floor is 0.03 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.11 to 0.36.

Min U-Factor
0.24
SHGC Range
0.11-0.36
Certified Options
139
Category Standing
#199 of 268

How does Windsor Windows and Doors Pinnacle Clad Outswing Door Stationary Panel compare thermally against Door peers?

Windsor Windows and Doors Pinnacle Clad Outswing Door Stationary Panel achieves a 0.24 thermal floor across Door lines, placing #199 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. Pinnacle Clad Outswing Door Stationary PanelHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing Pinnacle Clad Outswing Door Stationary Panel (U 0.24).28<=0.15650.16-0.18510.19-0.21710.22-0.24This model: U 0.24430.25-0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

Pinnacle Clad Outswing Door Stationary Panel Cohort StandingMin U-Factor 0.24 stands at rank #199 of 268, outperforming 19.8% of peers.Min U-Factor 0.24Rank #199 of 268 (19.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Door assemblies nationwide (median U 0.21), Pinnacle Clad Outswing Door Stationary Panel is 0.03 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median while keeping Wood frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.24-0.28.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 59 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Registry history records EPA FENSTAR licensing on 2018-01-10 and v7.0 data certification on 2024-02-16. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.24 conducts 144.0 BTU/hr (+12.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 139 certified glazing combinations for Pinnacle Clad Outswing Door Stationary Panel (NFRC WIN) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 59 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 59 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 125 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 125 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Windsor Windows and Doors produce?

Compare other active Windsor Windows and Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Windsor Windows and Doors Pinnacle Clad Outswing Door Stationary Panel appear below.

How efficient is Windsor Windows and Doors Pinnacle Clad Outswing Door Stationary Panel compared with peer Door models?

Testing puts Windsor Windows and Doors Pinnacle Clad Outswing Door Stationary Panel at rank #199 of 268 Door entries with U 0.24 to 0.28 across 139 configurations. Solar heat gain ranges between 0.11 and 0.36 across Northern, North-Central, South-Central, Southern.

Which glazing options in Windsor Windows and Doors Pinnacle Clad Outswing Door Stationary Panel meet Northern climate limits?

Because Pinnacle Clad Outswing Door Stationary Panel starts at 0.24 U-Factor, it exceeds the 0.22 prescriptive ceiling. Instead, 59 Northern packages qualify through EPA Equivalent Energy Performance rules pairing U 0.23-0.26 with higher SHGC (>= 0.35 or >= 0.40).

How do you calculate winter heat conduction for Windsor Windows and Doors Pinnacle Clad Outswing Door Stationary Panel?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Pinnacle Clad Outswing Door Stationary Panel at U 0.24 conducts 144.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

What are the practical limitations of specifying Pinnacle Clad Outswing Door Stationary Panel?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Pinnacle Clad Outswing Door Stationary Panel options exceeding U 0.22. Additionally, do not order Entry Door Single-Lite (EDSL) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

What Southern ENERGY STAR v7.0 options exist in Pinnacle Clad Outswing Door Stationary Panel?

Yes. 125 Southern-certified options inside Windsor Windows and Doors Pinnacle Clad Outswing Door Stationary Panel satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.36 SHGC on west-facing glass to avoid excess afternoon solar gain.

Which package tier in Pinnacle Clad Outswing Door Stationary Panel holds Most Efficient recognition?

All 139 Pinnacle Clad Outswing Door Stationary Panel listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

What 2026 federal tax credit and Lead RRP rules apply to Pinnacle Clad Outswing Door Stationary Panel?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How can homeowners confirm delivered Windsor Windows and Doors Pinnacle Clad Outswing Door Stationary Panel units match permits?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code WIN and product line WIN-N-130, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Windsor Windows and Doors Pinnacle Clad Outswing Door Stationary Panel come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)