Andersen Corporation — 400 Series Frenchwood® Hinged Patio Door - Inswing · Swinging Entry Door (Double)
Andersen Corporation 400 Series Frenchwood® Hinged Patio Door - Inswing is a Swinging Entry Door, Double assembly with a Wood frame that reaches a minimum U-Factor of 0.24 across 488 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #199 of 268 in Door, its thermal floor is 0.03 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.10 to 0.32.
- Min U-Factor
- 0.24
- SHGC Range
- 0.10-0.32
- Certified Options
- 488
- Category Standing
- #199 of 268
How does Andersen Corporation 400 Series Frenchwood® Hinged Patio Door - Inswing compare thermally against Door peers?
Andersen Corporation 400 Series Frenchwood® Hinged Patio Door - Inswing achieves a 0.24 thermal floor across Door lines, placing #199 of 268 against the 0.21 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Relative to Door assemblies nationwide (median U 0.21), 400 Series Frenchwood® Hinged Patio Door - Inswing is 0.03 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median while keeping Wood frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.24-0.28.
Regional qualification covers Northern, North-Central, South-Central, Southern. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 166 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).
Registry history records EPA FENSTAR licensing on 2019-01-08 and v7.0 data certification on 2025-03-12. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.24 conducts 144.0 BTU/hr (+12.0 BTU/hr vs the 0.22 ceiling).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 488 certified glazing combinations for 400 Series Frenchwood® Hinged Patio Door - Inswing (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Equiv. Path | <= 0.22 | >= 0.17 | 166 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 166 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 462 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 462 packages (0 Most Eff.) |
Which competing Door series sit closest on U-Factor?
Inspect nearby Door competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Sierra Pacific Windows — Wood Patio Slider | Wood | 0.24 | 0.09 | 233 |
| Weather Shield Mfg., Inc. — 8723 Next Gen Sliding Patio Door – Direct Set | Wood | 0.24 | 0.15 | 180 |
| Marvin — Infinity Inswing French Door | Wood | 0.24 | 0.14 | 174 |
| Windsor Windows and Doors — Pinnacle Clad Outswing Door Stationary Panel | Wood | 0.24 | 0.11 | 139 |
| Marvin — Elevate Inswing French Door | Wood | 0.24 | 0.14 | 128 |
What other certified series does Andersen Corporation produce?
Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
100 Series/Series 2 Fixed/Specialty Windows
U-Factor 0.14–0.32 · 13,810 certified options.
Complementary Wood Specialty Windows - Direct-Set
U-Factor 0.14–0.32 · 7,588 certified options.
200 Series/400 Series Complementary Clad Specialty Windows
U-Factor 0.15–0.32 · 12,778 certified options.
400 Series Tilt-Wash Double-Hung Transom Full-Frame Window
U-Factor 0.15–0.32 · 2,446 certified options.
E-Series Specialty (Auxiliary) Window
U-Factor 0.15–0.32 · 16,775 certified options.
Renewal by Andersen® Entry Door – Panel Set Sidelight
U-Factor 0.15–0.28 · 24,853 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation 400 Series Frenchwood® Hinged Patio Door - Inswing appear below.
How well does 400 Series Frenchwood® Hinged Patio Door - Inswing by Andersen Corporation insulate relative to Door benchmarks?
Built with Wood framing in Hinged Patio French Door (DDFR) style, Andersen Corporation 400 Series Frenchwood® Hinged Patio Door - Inswing offers 488 Version 7.0 configurations from U 0.24 up to 0.28, posting +0.03 against the Door median of 0.21 with 0 Most Efficient picks.
How does Andersen Corporation 400 Series Frenchwood® Hinged Patio Door - Inswing satisfy Version 7.0 Northern criteria?
With a 0.24 minimum U-Factor, Andersen Corporation 400 Series Frenchwood® Hinged Patio Door - Inswing cannot satisfy prescriptive <= 0.22 Northern targets, yet 166 high-SHGC packages meet EPA's solar-gain Equivalent route for cold northern homes.
How do you calculate winter heat conduction for Andersen Corporation 400 Series Frenchwood® Hinged Patio Door - Inswing?
At U 0.24, a standard 3x5 ft (15 sq ft) 400 Series Frenchwood® Hinged Patio Door - Inswing opening transfers 144.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +12.0 BTU/hr difference.
What homeowner profiles are a poor match for Andersen Corporation 400 Series Frenchwood® Hinged Patio Door - Inswing?
Skip 400 Series Frenchwood® Hinged Patio Door - Inswing if local historic preservation boards prohibit Wood profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on 400 Series Frenchwood® Hinged Patio Door - Inswing options exceeding U 0.22.
Can you install Andersen Corporation 400 Series Frenchwood® Hinged Patio Door - Inswing in Southern or South-Central zones?
Warm-climate homeowners have 462 Southern-approved options within 400 Series Frenchwood® Hinged Patio Door - Inswing spanning SHGC down to 0.10. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.
What glazing share inside 400 Series Frenchwood® Hinged Patio Door - Inswing qualifies as Most Efficient?
No. Zero of the 488 configurations in Andersen Corporation 400 Series Frenchwood® Hinged Patio Door - Inswing hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.
What federal compliance checks govern 2026 400 Series Frenchwood® Hinged Patio Door - Inswing window swaps?
No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.
How do building inspectors verify 400 Series Frenchwood® Hinged Patio Door - Inswing glass specs on job sites?
Match the NFRC thermal sticker for code AND and line AND-N-10 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Andersen Corporation 400 Series Frenchwood® Hinged Patio Door - Inswing come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)