Skip to main content
Door · Wood Frame NFRC AND · Product Line AND-N-10

Andersen Corporation — 400 Series Frenchwood® Hinged Patio Door - Inswing · Swinging Entry Door (Double)

Andersen Corporation 400 Series Frenchwood® Hinged Patio Door - Inswing is a Swinging Entry Door, Double assembly with a Wood frame that reaches a minimum U-Factor of 0.24 across 488 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #199 of 268 in Door, its thermal floor is 0.03 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.10 to 0.32.

Min U-Factor
0.24
SHGC Range
0.10-0.32
Certified Options
488
Category Standing
#199 of 268

How does Andersen Corporation 400 Series Frenchwood® Hinged Patio Door - Inswing compare thermally against Door peers?

Andersen Corporation 400 Series Frenchwood® Hinged Patio Door - Inswing achieves a 0.24 thermal floor across Door lines, placing #199 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. 400 Series Frenchwood® Hinged Patio Door - InswingHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing 400 Series Frenchwood® Hinged Patio Door - Inswing (U 0.24).28<=0.15650.16-0.18510.19-0.21710.22-0.24This model: U 0.24430.25-0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

400 Series Frenchwood® Hinged Patio Door - Inswing Cohort StandingMin U-Factor 0.24 stands at rank #199 of 268, outperforming 19.8% of peers.Min U-Factor 0.24Rank #199 of 268 (19.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Door assemblies nationwide (median U 0.21), 400 Series Frenchwood® Hinged Patio Door - Inswing is 0.03 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median while keeping Wood frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.24-0.28.

Regional qualification covers Northern, North-Central, South-Central, Southern. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 166 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Registry history records EPA FENSTAR licensing on 2019-01-08 and v7.0 data certification on 2025-03-12. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.24 conducts 144.0 BTU/hr (+12.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 488 certified glazing combinations for 400 Series Frenchwood® Hinged Patio Door - Inswing (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 166 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 166 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 462 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 462 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation 400 Series Frenchwood® Hinged Patio Door - Inswing appear below.

How well does 400 Series Frenchwood® Hinged Patio Door - Inswing by Andersen Corporation insulate relative to Door benchmarks?

Built with Wood framing in Hinged Patio French Door (DDFR) style, Andersen Corporation 400 Series Frenchwood® Hinged Patio Door - Inswing offers 488 Version 7.0 configurations from U 0.24 up to 0.28, posting +0.03 against the Door median of 0.21 with 0 Most Efficient picks.

How does Andersen Corporation 400 Series Frenchwood® Hinged Patio Door - Inswing satisfy Version 7.0 Northern criteria?

With a 0.24 minimum U-Factor, Andersen Corporation 400 Series Frenchwood® Hinged Patio Door - Inswing cannot satisfy prescriptive <= 0.22 Northern targets, yet 166 high-SHGC packages meet EPA's solar-gain Equivalent route for cold northern homes.

How do you calculate winter heat conduction for Andersen Corporation 400 Series Frenchwood® Hinged Patio Door - Inswing?

At U 0.24, a standard 3x5 ft (15 sq ft) 400 Series Frenchwood® Hinged Patio Door - Inswing opening transfers 144.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +12.0 BTU/hr difference.

What homeowner profiles are a poor match for Andersen Corporation 400 Series Frenchwood® Hinged Patio Door - Inswing?

Skip 400 Series Frenchwood® Hinged Patio Door - Inswing if local historic preservation boards prohibit Wood profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on 400 Series Frenchwood® Hinged Patio Door - Inswing options exceeding U 0.22.

Can you install Andersen Corporation 400 Series Frenchwood® Hinged Patio Door - Inswing in Southern or South-Central zones?

Warm-climate homeowners have 462 Southern-approved options within 400 Series Frenchwood® Hinged Patio Door - Inswing spanning SHGC down to 0.10. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

What glazing share inside 400 Series Frenchwood® Hinged Patio Door - Inswing qualifies as Most Efficient?

No. Zero of the 488 configurations in Andersen Corporation 400 Series Frenchwood® Hinged Patio Door - Inswing hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.

What federal compliance checks govern 2026 400 Series Frenchwood® Hinged Patio Door - Inswing window swaps?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How do building inspectors verify 400 Series Frenchwood® Hinged Patio Door - Inswing glass specs on job sites?

Match the NFRC thermal sticker for code AND and line AND-N-10 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation 400 Series Frenchwood® Hinged Patio Door - Inswing come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros