Skip to main content
Door · Wood Frame NFRC MAR · Product Line MAR-N-438

Marvin — Infinity Inswing French Door · Swinging Entry Door (Double)

EPA ENERGY STAR Version 7.0 certifies 174 variants inside Marvin Infinity Inswing French Door, combining Wood frame with Fiberglass sash with U-Factors spanning 0.24 to 0.28 and SHGC 0.14 to 0.23. Qualifying for Northern, North-Central, South-Central, Southern, this Swinging Entry Door, Double family places #199 of 268 among 268 Door families and posts 0.03 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median among Wood peers.

Min U-Factor
0.24
SHGC Range
0.14-0.23
Certified Options
174
Category Standing
#199 of 268

How does Marvin Infinity Inswing French Door compare thermally against Door peers?

Marvin Infinity Inswing French Door achieves a 0.24 thermal floor across Door lines, placing #199 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. Infinity Inswing French DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing Infinity Inswing French Door (U 0.24).28<=0.15650.16-0.18510.19-0.21710.22-0.24This model: U 0.24430.25-0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

Infinity Inswing French Door Cohort StandingMin U-Factor 0.24 stands at rank #199 of 268, outperforming 19.8% of peers.Min U-Factor 0.24Rank #199 of 268 (19.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across Infinity Inswing French Door spans 174 NFRC test records (MAR), ranking #199 of 268 Door families (tied with 16 others at 0.24, more insulating than 19.8% of Door lines). Its 0.24 thermal floor compares at +0.03 against the Wood median (0.21).

Mapping NFRC SHGC values (0.14 to 0.23) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 84 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Registry history records EPA FENSTAR licensing on 2019-03-05 and v7.0 data certification on 2024-02-29. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.24 conducts 144.0 BTU/hr (+12.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 174 certified glazing combinations for Infinity Inswing French Door (NFRC MAR) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 84 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 84 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 174 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 174 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Marvin produce?

Compare other active Marvin certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Marvin Infinity Inswing French Door appear below.

What thermal performance numbers separate Marvin Infinity Inswing French Door from peers?

Across 174 tested NFRC glazing configurations, Marvin Infinity Inswing French Door with Wood framing and Hinged Patio French Door (DDFR) style reaches a 0.24 minimum U-Factor and 0.14-0.23 SHGC band. It places #199 among 268 Door series—more insulating than 19.8%.

Does Marvin Infinity Inswing French Door qualify for the ENERGY STAR Northern Zone?

Because Infinity Inswing French Door starts at 0.24 U-Factor, it exceeds the 0.22 prescriptive ceiling. Instead, 84 Northern packages qualify through EPA Equivalent Energy Performance rules pairing U 0.23-0.26 with higher SHGC (>= 0.35 or >= 0.40).

What BTU/hr heat transfer results from Infinity Inswing French Door's 0.24 minimum U-Factor?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.24 U-Factor yields 144.0 BTU/hr conductive transfer (+9.1% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

What homeowner profiles are a poor match for Marvin Infinity Inswing French Door?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Infinity Inswing French Door options exceeding U 0.22. Additionally, do not order Hinged Patio French Door (DDFR) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Does Infinity Inswing French Door meet Southern hot-climate SHGC caps (<= 0.23)?

Yes, Infinity Inswing French Door holds 174 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.14 SHGC in cooling climates.

What glazing share inside Infinity Inswing French Door qualifies as Most Efficient?

ENERGY STAR Most Efficient designation is absent across all 174 Infinity Inswing French Door options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

What 2026 federal tax credit and Lead RRP rules apply to Infinity Inswing French Door?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Marvin upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How do building inspectors verify Infinity Inswing French Door glass specs on job sites?

Verify NFRC ID MAR and series MAR-N-438 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Marvin Infinity Inswing French Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros