Window · Wood Frame NFRC MAR · Product Line MAR-N-318 ENERGY STAR Most Efficient Eligible

Marvin — Ultimate Wood Double Hung / Single Hung Magnum · Double Hung

With a minimum U-Factor of 0.13—-0.07 compared against the 0.20 Window median—Marvin Ultimate Wood Double Hung / Single Hung Magnum spans 2,481 tested options across Northern, North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code MAR, the Wood assembly includes 671 ENERGY STAR Most Efficient packages (27.0% of line) and offers SHGC packages between 0.10 and 0.44.

Min U-Factor
0.13
SHGC Range
0.10-0.44
Certified Options
2,481
Category Standing
#36 of 1,352

How does Marvin Ultimate Wood Double Hung / Single Hung Magnum compare thermally against Window peers?

Marvin Ultimate Wood Double Hung / Single Hung Magnum achieves a 0.13 thermal floor across Window lines, placing #36 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Ultimate Wood Double Hung / Single Hung MagnumHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing Ultimate Wood Double Hung / Single Hung Magnum (U 0.13).249<=0.15This model: U 0.133140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Ultimate Wood Double Hung / Single Hung Magnum Cohort StandingMin U-Factor 0.13 stands at rank #36 of 1,352, outperforming 94.7% of peers.Min U-Factor 0.13Rank #36 of 1,352 (94.7% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Wood cohort (0.21 median U-Factor), Ultimate Wood Double Hung / Single Hung Magnum reaches 0.13 on its lowest-conductivity package — #10 of 408 in Wood, tied with 12 others at 0.13, more insulating than 94.6% of Wood lines, top 5.4% (-0.08 vs Wood peers). Pairing NFRC ID MAR across multi-pane fills shifts U-Factor from 0.32 down toward 0.13.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 671 configurations meet ENERGY STAR Most Efficient criteria while 653 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2024-04-24 and FENSTAR license 2019-03-05 inside EPA Version 7.0 tables. Heat transfer computes to 78.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 2,481 certified glazing combinations for Ultimate Wood Double Hung / Single Hung Magnum (NFRC MAR) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 653 packages (369 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 1,145 packages (587 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 1,259 packages (375 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 2,047 packages (455 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.13 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Marvin produce?

Compare other active Marvin certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Marvin Ultimate Wood Double Hung / Single Hung Magnum appear below.

What thermal performance numbers separate Marvin Ultimate Wood Double Hung / Single Hung Magnum from peers?

EPA ENERGY STAR v7.0 records 2,481 configurations for Marvin Ultimate Wood Double Hung / Single Hung Magnum covering Northern, North-Central, South-Central, Southern, dropping down to U 0.13 versus a 0.20 Window median. Only 671 options earn Most Efficient status.

Which glazing options in Marvin Ultimate Wood Double Hung / Single Hung Magnum meet Northern climate limits?

Yes. 653 packages in Marvin Ultimate Wood Double Hung / Single Hung Magnum clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.

How do you calculate winter heat conduction for Marvin Ultimate Wood Double Hung / Single Hung Magnum?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Ultimate Wood Double Hung / Single Hung Magnum at U 0.13 conducts 78.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

Which situations make Ultimate Wood Double Hung / Single Hung Magnum the wrong window or door choice?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Ultimate Wood Double Hung / Single Hung Magnum options exceeding U 0.22. Verify whether your municipal code restricts Wood frames in wildfire or historic zones.

How many Ultimate Wood Double Hung / Single Hung Magnum glazing packages pass Southern solar-heat rules?

Across Northern, North-Central, South-Central, Southern, 2,047 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Marvin Ultimate Wood Double Hung / Single Hung Magnum, while total line SHGC reaches 0.44 in colder packages.

Does Ultimate Wood Double Hung / Single Hung Magnum carry EPA Most Efficient certification across its lineup?

Within Ultimate Wood Double Hung / Single Hung Magnum, 27.0% (671 of 2,481) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

Can homeowners claim Form 5695 credits on Marvin Ultimate Wood Double Hung / Single Hung Magnum in 2026?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Marvin upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How do you cross-check NFRC MAR and product line MAR-N-318 on delivery?

Inspectors match the temporary NFRC sticker (U 0.13-0.32, SHGC 0.10-0.44) against permit drawings for line MAR-N-318. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Marvin Ultimate Wood Double Hung / Single Hung Magnum come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)