Skip to main content
Window · Wood Frame NFRC KKM · Product Line KKM-N-290 ENERGY STAR Most Efficient Eligible

Kolbe and Kolbe Millwork Co., Inc — Ultra XL Casement Picture · Picture Window

Positioning #36/1,352 in certified Window, Kolbe and Kolbe Millwork Co., Inc Ultra XL Casement Picture pairs Wood frame construction with 1,118 glazing options rated between 0.10 and 0.49 SHGC across Northern, North-Central, South-Central, Southern. Across 57 certified Kolbe and Kolbe Millwork Co., Inc product families, its thermal resistance spans 0.13 to 0.32 U-Factor and the line includes 735 ENERGY STAR Most Efficient packages (65.7% of line).

Min U-Factor
0.13
SHGC Range
0.10-0.49
Certified Options
1,118
Category Standing
#36 of 1,352

How does Kolbe and Kolbe Millwork Co., Inc Ultra XL Casement Picture compare thermally against Window peers?

Kolbe and Kolbe Millwork Co., Inc Ultra XL Casement Picture achieves a 0.13 thermal floor across Window lines, placing #36 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Ultra XL Casement PictureHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing Ultra XL Casement Picture (U 0.13).249<=0.15This model: U 0.133140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Ultra XL Casement Picture Cohort StandingMin U-Factor 0.13 stands at rank #36 of 1,352, outperforming 94.7% of peers.Min U-Factor 0.13Rank #36 of 1,352 (94.7% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across Ultra XL Casement Picture spans 1,118 NFRC test records (KKM), ranking #36 of 1,352 Window families (tied with 35 others at 0.13, more insulating than 94.7% of Window lines, top 5.3%). Its 0.13 thermal floor compares at -0.08 against the Wood median (0.21).

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 735 configurations meet ENERGY STAR Most Efficient criteria while 440 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2026-04-29 and FENSTAR license 2018-02-20 inside EPA Version 7.0 tables. Heat transfer computes to 78.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,118 certified glazing combinations for Ultra XL Casement Picture (NFRC KKM) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 440 packages (303 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 824 packages (694 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 765 packages (543 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 890 packages (557 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.13 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Kolbe and Kolbe Millwork Co., Inc produce?

Compare other active Kolbe and Kolbe Millwork Co., Inc certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kolbe and Kolbe Millwork Co., Inc Ultra XL Casement Picture appear below.

How efficient is Kolbe and Kolbe Millwork Co., Inc Ultra XL Casement Picture compared with peer Window models?

Across 1,118 tested NFRC glazing configurations, Kolbe and Kolbe Millwork Co., Inc Ultra XL Casement Picture with Wood framing and Fixed Window (FIXD) style reaches a 0.13 minimum U-Factor and 0.10-0.49 SHGC band. It places #36 among 1,352 Window series—top 5.3%.

Does Kolbe and Kolbe Millwork Co., Inc Ultra XL Casement Picture qualify for the ENERGY STAR Northern Zone?

Yes, 440 packages satisfy Northern ENERGY STAR Version 7.0 rules in Ultra XL Casement Picture. Pairing multi-pane insulation down to 0.13 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

How do you calculate winter heat conduction for Kolbe and Kolbe Millwork Co., Inc Ultra XL Casement Picture?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.13 U-Factor yields 78.0 BTU/hr conductive transfer (-40.9% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

When should a buyer skip Kolbe and Kolbe Millwork Co., Inc Ultra XL Casement Picture and compare alternatives?

Do not specify Ultra XL Casement Picture without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Ultra XL Casement Picture options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

How many Ultra XL Casement Picture glazing packages pass Southern solar-heat rules?

Yes, Ultra XL Casement Picture holds 890 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.10 SHGC in cooling climates.

Which package tier in Ultra XL Casement Picture holds Most Efficient recognition?

No. Exactly 735 of 1,118 configurations (65.7%) earn ENERGY STAR Most Efficient status in Ultra XL Casement Picture; the remaining standard v7.0 options pass base zone limits only.

What 2026 federal tax credit and Lead RRP rules apply to Ultra XL Casement Picture?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How can homeowners confirm delivered Kolbe and Kolbe Millwork Co., Inc Ultra XL Casement Picture units match permits?

Match the NFRC thermal sticker for code KKM and line KKM-N-290 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Kolbe and Kolbe Millwork Co., Inc Ultra XL Casement Picture come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)