Skip to main content
Window · Wood Frame NFRC KKM · Product Line KKM-N-178 ENERGY STAR Most Efficient Eligible

Kolbe and Kolbe Millwork Co., Inc — Heritage Inswing Casement Picture · Picture Window

Kolbe and Kolbe Millwork Co., Inc engineered the Heritage Inswing Casement Picture Picture Window line for Northern, North-Central, South-Central, Southern, certifying 1,123 glass-spacer combinations from 0.13 to 0.32 U-Factor and 0.09 to 0.48 SHGC. Relative to other Wood models tracked under NFRC KKM, its minimum U-Factor is 0.08 Btu/hr·ft²·°F more insulating than the 0.21 Btu/hr·ft²·°F median.

Min U-Factor
0.13
SHGC Range
0.09-0.48
Certified Options
1,123
Category Standing
#36 of 1,352

How does Kolbe and Kolbe Millwork Co., Inc Heritage Inswing Casement Picture compare thermally against Window peers?

Kolbe and Kolbe Millwork Co., Inc Heritage Inswing Casement Picture achieves a 0.13 thermal floor across Window lines, placing #36 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Heritage Inswing Casement PictureHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing Heritage Inswing Casement Picture (U 0.13).249<=0.15This model: U 0.133140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Heritage Inswing Casement Picture Cohort StandingMin U-Factor 0.13 stands at rank #36 of 1,352, outperforming 94.7% of peers.Min U-Factor 0.13Rank #36 of 1,352 (94.7% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Kolbe and Kolbe Millwork Co., Inc Heritage Inswing Casement Picture at rank #36 of 1,352 (tied with 35 others at 0.13, more insulating than 94.7% of Window lines, top 5.3%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.09-0.48 band.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 749 configurations meet ENERGY STAR Most Efficient criteria while 408 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.13 U-Factor yields 78.0 BTU/hr transfer (-54.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-02-20 licensing and 2026-09-25 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,123 certified glazing combinations for Heritage Inswing Casement Picture (NFRC KKM) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 408 packages (302 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 808 packages (725 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 808 packages (571 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 924 packages (571 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.13 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Kolbe and Kolbe Millwork Co., Inc produce?

Compare other active Kolbe and Kolbe Millwork Co., Inc certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kolbe and Kolbe Millwork Co., Inc Heritage Inswing Casement Picture appear below.

What U-Factor and SHGC range does Kolbe and Kolbe Millwork Co., Inc Heritage Inswing Casement Picture achieve?

Kolbe and Kolbe Millwork Co., Inc Heritage Inswing Casement Picture spans 1,123 certified configurations with U-Factors between 0.13 and 0.32 and SHGC values from 0.09 to 0.48. Ranked #36 of 1,352 Window families, it carries 749 Most Efficient options.

Does Kolbe and Kolbe Millwork Co., Inc Heritage Inswing Casement Picture qualify for the ENERGY STAR Northern Zone?

Yes. 408 packages in Kolbe and Kolbe Millwork Co., Inc Heritage Inswing Casement Picture clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.

How do you calculate winter heat conduction for Kolbe and Kolbe Millwork Co., Inc Heritage Inswing Casement Picture?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.13 U-Factor yields 78.0 BTU/hr conductive transfer (-40.9% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

Who should NOT choose Kolbe and Kolbe Millwork Co., Inc Heritage Inswing Casement Picture for a residential project?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Heritage Inswing Casement Picture options exceeding U 0.22. Verify whether your municipal code restricts Wood frames in wildfire or historic zones.

Does Heritage Inswing Casement Picture meet Southern hot-climate SHGC caps (<= 0.23)?

Across Northern, North-Central, South-Central, Southern, 924 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Kolbe and Kolbe Millwork Co., Inc Heritage Inswing Casement Picture, while total line SHGC reaches 0.48 in colder packages.

Which package tier in Heritage Inswing Casement Picture holds Most Efficient recognition?

No. Exactly 749 of 1,123 configurations (66.7%) earn ENERGY STAR Most Efficient status in Heritage Inswing Casement Picture; the remaining standard v7.0 options pass base zone limits only.

Do 2026 Heritage Inswing Casement Picture installations qualify for IRS Section 25C tax credits?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Kolbe and Kolbe Millwork Co., Inc upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

Where are NFRC and IGCC identification marks located on Heritage Inswing Casement Picture?

Verify NFRC ID KKM and series KKM-N-178 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Kolbe and Kolbe Millwork Co., Inc Heritage Inswing Casement Picture come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)