Skip to main content
Window · Wood Frame NFRC WIN · Product Line WIN-N-187 ENERGY STAR Most Efficient Eligible

Windsor Windows and Doors — Pinnacle Clad Direct Set 3.25" Frame · Picture Window

Windsor Windows and Doors Pinnacle Clad Direct Set 3.25" Frame is a Picture Window assembly with a Wood frame that reaches a minimum U-Factor of 0.17 across 817 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #362 of 1,352 in Window, its thermal floor is 0.03 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.13 to 0.56.

Min U-Factor
0.17
SHGC Range
0.13-0.56
Certified Options
817
Category Standing
#362 of 1,352

How does Windsor Windows and Doors Pinnacle Clad Direct Set 3.25" Frame compare thermally against Window peers?

Windsor Windows and Doors Pinnacle Clad Direct Set 3.25" Frame achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Pinnacle Clad Direct Set 3.25" FrameHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing Pinnacle Clad Direct Set 3.25" Frame (U 0.17).249<=0.153140.16-0.18This model: U 0.172670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Pinnacle Clad Direct Set 3.25" Frame Cohort StandingMin U-Factor 0.17 stands at rank #362 of 1,352, outperforming 64.8% of peers.Min U-Factor 0.17Rank #362 of 1,352 (64.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across Pinnacle Clad Direct Set 3.25" Frame spans 817 NFRC test records (WIN), ranking #362 of 1,352 Window families (tied with 114 others at 0.17, more insulating than 64.8% of Window lines, top 35.2%). Its 0.17 thermal floor compares at -0.04 against the Wood median (0.21).

Regional qualification covers Northern, North-Central, South-Central, Southern. 89 configurations meet ENERGY STAR Most Efficient criteria while 194 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2025-11-19 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 102.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 817 certified glazing combinations for Pinnacle Clad Direct Set 3.25" Frame (NFRC WIN) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 194 packages (50 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 159 packages (37 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 321 packages (33 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 668 packages (60 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Windsor Windows and Doors produce?

Compare other active Windsor Windows and Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Windsor Windows and Doors Pinnacle Clad Direct Set 3.25" Frame appear below.

How well does Pinnacle Clad Direct Set 3.25" Frame by Windsor Windows and Doors insulate relative to Window benchmarks?

Windsor Windows and Doors Pinnacle Clad Direct Set 3.25" Frame spans 817 certified configurations with U-Factors between 0.17 and 0.32 and SHGC values from 0.13 to 0.56. Ranked #362 of 1,352 Window families, it carries 89 Most Efficient options.

Does Windsor Windows and Doors Pinnacle Clad Direct Set 3.25" Frame qualify for the ENERGY STAR Northern Zone?

Cold-climate buyers get 194 compliant Northern packages inside Pinnacle Clad Direct Set 3.25" Frame, reaching down to U 0.17. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.

How much winter heat loss does Pinnacle Clad Direct Set 3.25" Frame conduct across a 15 sq ft opening?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Pinnacle Clad Direct Set 3.25" Frame at U 0.17 conducts 102.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

What are the practical limitations of specifying Pinnacle Clad Direct Set 3.25" Frame?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Pinnacle Clad Direct Set 3.25" Frame options exceeding U 0.22. Additionally, do not order Fixed Window (FIXD) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Is Pinnacle Clad Direct Set 3.25" Frame suitable for sunbelt cooling-dominated homes?

Across Northern, North-Central, South-Central, Southern, 668 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Windsor Windows and Doors Pinnacle Clad Direct Set 3.25" Frame, while total line SHGC reaches 0.56 in colder packages.

Does Pinnacle Clad Direct Set 3.25" Frame carry EPA Most Efficient certification across its lineup?

Within Pinnacle Clad Direct Set 3.25" Frame, 10.9% (89 of 817) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

How do the 25C sunset and pre-1978 Lead RRP rules affect Pinnacle Clad Direct Set 3.25" Frame?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Windsor Windows and Doors upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How do you cross-check NFRC WIN and product line WIN-N-187 on delivery?

Match the NFRC thermal sticker for code WIN and line WIN-N-187 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Windsor Windows and Doors Pinnacle Clad Direct Set 3.25" Frame come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)