Skip to main content
Window · Wood Frame NFRC KKM · Product Line KKM-N-279 ENERGY STAR Most Efficient Eligible

Kolbe and Kolbe Millwork Co., Inc — Ultra Sterling Double Hung · Double Hung

Positioning #362/1,352 in certified Window, Kolbe and Kolbe Millwork Co., Inc Ultra Sterling Double Hung pairs Wood frame construction with 638 glazing options rated between 0.09 and 0.43 SHGC across Northern, North-Central, South-Central, Southern. Across 57 certified Kolbe and Kolbe Millwork Co., Inc product families, its thermal resistance spans 0.17 to 0.32 U-Factor and the line includes 420 ENERGY STAR Most Efficient packages (65.8% of line).

Min U-Factor
0.17
SHGC Range
0.09-0.43
Certified Options
638
Category Standing
#362 of 1,352

How does Kolbe and Kolbe Millwork Co., Inc Ultra Sterling Double Hung compare thermally against Window peers?

Kolbe and Kolbe Millwork Co., Inc Ultra Sterling Double Hung achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Ultra Sterling Double HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing Ultra Sterling Double Hung (U 0.17).249<=0.153140.16-0.18This model: U 0.172670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Ultra Sterling Double Hung Cohort StandingMin U-Factor 0.17 stands at rank #362 of 1,352, outperforming 64.8% of peers.Min U-Factor 0.17Rank #362 of 1,352 (64.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 57 certified Kolbe and Kolbe Millwork Co., Inc series, this Double Hung offers a 0.15 U-Factor adjustment span between 0.32 entry options and 0.17 top-performing glazing. Category standing is #362/1,352 (tied with 114 others at 0.17, more insulating than 64.8% of Window lines, top 35.2%).

Mapping NFRC SHGC values (0.09 to 0.43) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 420 configurations meet ENERGY STAR Most Efficient criteria while 190 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2018-02-20 and v7.0 data certification on 2025-11-19. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.17 conducts 102.0 BTU/hr (-30.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 638 certified glazing combinations for Ultra Sterling Double Hung (NFRC KKM) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 190 packages (128 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 428 packages (400 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 404 packages (320 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 550 packages (340 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Kolbe and Kolbe Millwork Co., Inc produce?

Compare other active Kolbe and Kolbe Millwork Co., Inc certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kolbe and Kolbe Millwork Co., Inc Ultra Sterling Double Hung appear below.

What U-Factor and SHGC range does Kolbe and Kolbe Millwork Co., Inc Ultra Sterling Double Hung achieve?

Across 638 tested NFRC glazing configurations, Kolbe and Kolbe Millwork Co., Inc Ultra Sterling Double Hung with Wood framing and Double-Hung (VSDH) style reaches a 0.17 minimum U-Factor and 0.09-0.43 SHGC band. It places #362 among 1,352 Window series—top 35.2%.

How does Kolbe and Kolbe Millwork Co., Inc Ultra Sterling Double Hung satisfy Version 7.0 Northern criteria?

Prescriptive Northern compliance covers 190 Ultra Sterling Double Hung packages (U floor 0.17, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.

What BTU/hr heat transfer results from Ultra Sterling Double Hung's 0.17 minimum U-Factor?

At U 0.17, a standard 3x5 ft (15 sq ft) Ultra Sterling Double Hung opening transfers 102.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -30.0 BTU/hr difference.

What are the practical limitations of specifying Ultra Sterling Double Hung?

Skip Ultra Sterling Double Hung if local historic preservation boards prohibit Wood profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Ultra Sterling Double Hung options exceeding U 0.22.

Does Ultra Sterling Double Hung meet Southern hot-climate SHGC caps (<= 0.23)?

Across Northern, North-Central, South-Central, Southern, 550 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Kolbe and Kolbe Millwork Co., Inc Ultra Sterling Double Hung, while total line SHGC reaches 0.43 in colder packages.

What glazing share inside Ultra Sterling Double Hung qualifies as Most Efficient?

Within Ultra Sterling Double Hung, 65.8% (420 of 638) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

How do the 25C sunset and pre-1978 Lead RRP rules affect Ultra Sterling Double Hung?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Kolbe and Kolbe Millwork Co., Inc upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How do building inspectors verify Ultra Sterling Double Hung glass specs on job sites?

Confirm both the paper NFRC label and permanent corner glass etch match line KKM-N-279 and NFRC ID KKM before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Kolbe and Kolbe Millwork Co., Inc Ultra Sterling Double Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros