Window · Wood Frame NFRC WEA · Product Line WEA-N-285 ENERGY STAR Most Efficient Eligible

Weather Shield Mfg., Inc. — 8211/8216/1209/1210 Premium Casement Picture · Picture Window

Positioning #362/1,352 in certified Window, Weather Shield Mfg., Inc. 8211/8216/1209/1210 Premium Casement Picture pairs Wood frame construction with 885 glazing options rated between 0.12 and 0.50 SHGC across Northern, North-Central, South-Central, Southern. Across 30 certified Weather Shield Mfg., Inc. product families, its thermal resistance spans 0.17 to 0.32 U-Factor and the line includes 132 ENERGY STAR Most Efficient packages (14.9% of line).

Min U-Factor
0.17
SHGC Range
0.12-0.50
Certified Options
885
Category Standing
#362 of 1,352

How does Weather Shield Mfg., Inc. 8211/8216/1209/1210 Premium Casement Picture compare thermally against Window peers?

Weather Shield Mfg., Inc. 8211/8216/1209/1210 Premium Casement Picture achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 8211/8216/1209/1210 Premium Casement PictureHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing 8211/8216/1209/1210 Premium Casement Picture (U 0.17).249<=0.153140.16-0.18This model: U 0.172670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

8211/8216/1209/1210 Premium Casement Picture Cohort StandingMin U-Factor 0.17 stands at rank #362 of 1,352, outperforming 64.8% of peers.Min U-Factor 0.17Rank #362 of 1,352 (64.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Wood cohort (0.21 median U-Factor), 8211/8216/1209/1210 Premium Casement Picture reaches 0.17 on its lowest-conductivity package — #88 of 408 in Wood, tied with 34 others at 0.17, more insulating than 70.1% of Wood lines, top 29.9% (-0.04 vs Wood peers). Pairing NFRC ID WEA across multi-pane fills shifts U-Factor from 0.32 down toward 0.17.

Regional qualification covers Northern, North-Central, South-Central, Southern. 132 configurations meet ENERGY STAR Most Efficient criteria while 163 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2018-02-20 and v7.0 data certification on 2024-04-02. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.17 conducts 102.0 BTU/hr (-30.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 885 certified glazing combinations for 8211/8216/1209/1210 Premium Casement Picture (NFRC WEA) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 163 packages (41 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 324 packages (81 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 453 packages (51 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 730 packages (102 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Weather Shield Mfg., Inc. produce?

Compare other active Weather Shield Mfg., Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Weather Shield Mfg., Inc. 8211/8216/1209/1210 Premium Casement Picture appear below.

How well does 8211/8216/1209/1210 Premium Casement Picture by Weather Shield Mfg., Inc. insulate relative to Window benchmarks?

EPA ENERGY STAR v7.0 records 885 configurations for Weather Shield Mfg., Inc. 8211/8216/1209/1210 Premium Casement Picture covering Northern, North-Central, South-Central, Southern, dropping down to U 0.17 versus a 0.20 Window median. Only 132 options earn Most Efficient status.

How does Weather Shield Mfg., Inc. 8211/8216/1209/1210 Premium Casement Picture satisfy Version 7.0 Northern criteria?

Yes, 163 packages satisfy Northern ENERGY STAR Version 7.0 rules in 8211/8216/1209/1210 Premium Casement Picture. Pairing multi-pane insulation down to 0.17 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

How much winter heat loss does 8211/8216/1209/1210 Premium Casement Picture conduct across a 15 sq ft opening?

At U 0.17, a standard 3x5 ft (15 sq ft) 8211/8216/1209/1210 Premium Casement Picture opening transfers 102.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -30.0 BTU/hr difference.

What homeowner profiles are a poor match for Weather Shield Mfg., Inc. 8211/8216/1209/1210 Premium Casement Picture?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 8211/8216/1209/1210 Premium Casement Picture options exceeding U 0.22. Additionally, do not order Fixed Window (FIXD) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

What Southern ENERGY STAR v7.0 options exist in 8211/8216/1209/1210 Premium Casement Picture?

Exactly 730 8211/8216/1209/1210 Premium Casement Picture options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.12 rather than higher 0.50 glass.

How many Weather Shield Mfg., Inc. 8211/8216/1209/1210 Premium Casement Picture variants earn ENERGY STAR Most Efficient?

EPA lists 132 Most Efficient options (14.9% share) inside Weather Shield Mfg., Inc. 8211/8216/1209/1210 Premium Casement Picture, out of 885 total Version 7.0 entries.

What federal compliance checks govern 2026 8211/8216/1209/1210 Premium Casement Picture window swaps?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 8211/8216/1209/1210 Premium Casement Picture installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

How do building inspectors verify 8211/8216/1209/1210 Premium Casement Picture glass specs on job sites?

Match the NFRC thermal sticker for code WEA and line WEA-N-285 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Weather Shield Mfg., Inc. 8211/8216/1209/1210 Premium Casement Picture come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros