Skip to main content
Window · Vinyl Frame NFRC WIN · Product Line WIN-N-189 ENERGY STAR Most Efficient Eligible

Windsor Windows and Doors — Next Dimension Casement Picture · Picture Window

Across 82 Windsor Windows and Doors certified families, Next Dimension Casement Picture supplies 1,610 Picture Window configurations starting at 0.17 U-Factor and 0.12 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.51 SHGC. Its thermal floor ranks #362 of 1,352 category entries—0.03 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.17
SHGC Range
0.12-0.51
Certified Options
1,610
Category Standing
#362 of 1,352

How does Windsor Windows and Doors Next Dimension Casement Picture compare thermally against Window peers?

Windsor Windows and Doors Next Dimension Casement Picture achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Next Dimension Casement PictureHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing Next Dimension Casement Picture (U 0.17).249<=0.153140.16-0.18This model: U 0.172670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Next Dimension Casement Picture Cohort StandingMin U-Factor 0.17 stands at rank #362 of 1,352, outperforming 64.8% of peers.Min U-Factor 0.17Rank #362 of 1,352 (64.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Windsor Windows and Doors Next Dimension Casement Picture standing at #362 of 1,352 certified Window product series, tied with 114 others at 0.17, more insulating than 64.8% of Window lines, top 35.2%. Comparing Vinyl profiles alone (median 0.19) shows -0.02 before selecting Low-E tiers.

Mapping NFRC SHGC values (0.12 to 0.51) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 170 configurations meet ENERGY STAR Most Efficient criteria while 346 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2018-01-10 and v7.0 data certification on 2025-08-21. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.17 conducts 102.0 BTU/hr (-30.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,610 certified glazing combinations for Next Dimension Casement Picture (NFRC WIN) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 346 packages (56 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 333 packages (82 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 802 packages (55 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 1,383 packages (125 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Vinylmax LLC — CP74 Picture Window Vinyl 0.17 0.14 1,603
DRUTEX S.A. — IGLO 5 Classic Tilt Turn Vinyl 0.17 0.04 1,631
Wincore Window Company, LLC — 5400 5400S 7700 9900 Series Vinyl Fixed Window Transom Vinyl 0.17 0.14 1,833
Lindsay Windows — Pinnacle / Healthy Double Hung Vinyl 0.17 0.16 1,344
Sierra Pacific Windows — Vinyl Direct Set Vinyl 0.17 0.12 2,077

What other certified series does Windsor Windows and Doors produce?

Compare other active Windsor Windows and Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Windsor Windows and Doors Next Dimension Casement Picture appear below.

What thermal performance numbers separate Windsor Windows and Doors Next Dimension Casement Picture from peers?

Windsor Windows and Doors Next Dimension Casement Picture spans 1,610 certified configurations with U-Factors between 0.17 and 0.32 and SHGC values from 0.12 to 0.51. Ranked #362 of 1,352 Window families, it carries 170 Most Efficient options.

Which glazing options in Windsor Windows and Doors Next Dimension Casement Picture meet Northern climate limits?

Cold-climate buyers get 346 compliant Northern packages inside Next Dimension Casement Picture, reaching down to U 0.17. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.

What BTU/hr heat transfer results from Next Dimension Casement Picture's 0.17 minimum U-Factor?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Next Dimension Casement Picture at U 0.17 conducts 102.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

When should a buyer skip Windsor Windows and Doors Next Dimension Casement Picture and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Next Dimension Casement Picture options exceeding U 0.22. Additionally, do not order Fixed Window (FIXD) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Can you install Windsor Windows and Doors Next Dimension Casement Picture in Southern or South-Central zones?

Yes, Next Dimension Casement Picture holds 1,383 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.12 SHGC in cooling climates.

Does Next Dimension Casement Picture carry EPA Most Efficient certification across its lineup?

Within Next Dimension Casement Picture, 10.6% (170 of 1,610) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

Do 2026 Next Dimension Casement Picture installations qualify for IRS Section 25C tax credits?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 Next Dimension Casement Picture installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

How do you cross-check NFRC WIN and product line WIN-N-189 on delivery?

Confirm both the paper NFRC label and permanent corner glass etch match line WIN-N-189 and NFRC ID WIN before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Windsor Windows and Doors Next Dimension Casement Picture come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros