Skip to main content
Window · Wood Frame NFRC WIN · Product Line WIN-N-112 ENERGY STAR Most Efficient Eligible

Windsor Windows and Doors — Pinnacle Clad Radius Direct Glaze · Picture Window

Positioning #136/1,352 in certified Window, Windsor Windows and Doors Pinnacle Clad Radius Direct Glaze pairs Wood frame construction with 1,266 glazing options rated between 0.13 and 0.55 SHGC across Northern, North-Central, South-Central, Southern. Across 82 certified Windsor Windows and Doors product families, its thermal resistance spans 0.15 to 0.32 U-Factor and the line includes 360 ENERGY STAR Most Efficient packages (28.4% of line).

Min U-Factor
0.15
SHGC Range
0.13-0.55
Certified Options
1,266
Category Standing
#136 of 1,352

How does Windsor Windows and Doors Pinnacle Clad Radius Direct Glaze compare thermally against Window peers?

Windsor Windows and Doors Pinnacle Clad Radius Direct Glaze achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Pinnacle Clad Radius Direct GlazeHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing Pinnacle Clad Radius Direct Glaze (U 0.15).249<=0.15This model: U 0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Pinnacle Clad Radius Direct Glaze Cohort StandingMin U-Factor 0.15 stands at rank #136 of 1,352, outperforming 81.6% of peers.Min U-Factor 0.15Rank #136 of 1,352 (81.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Windsor Windows and Doors Pinnacle Clad Radius Direct Glaze standing at #136 of 1,352 certified Window product series, tied with 113 others at 0.15, more insulating than 81.6% of Window lines, top 18.4%. Comparing Wood profiles alone (median 0.21) shows -0.06 before selecting Low-E tiers.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 360 configurations meet ENERGY STAR Most Efficient criteria while 498 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 90.0 BTU/hr (-31.8% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2024-02-14.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,266 certified glazing combinations for Pinnacle Clad Radius Direct Glaze (NFRC WIN) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 498 packages (252 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 571 packages (257 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 553 packages (102 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 848 packages (149 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Windsor Windows and Doors produce?

Compare other active Windsor Windows and Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Windsor Windows and Doors Pinnacle Clad Radius Direct Glaze appear below.

How well does Pinnacle Clad Radius Direct Glaze by Windsor Windows and Doors insulate relative to Window benchmarks?

Windsor Windows and Doors Pinnacle Clad Radius Direct Glaze spans 1,266 certified configurations with U-Factors between 0.15 and 0.32 and SHGC values from 0.13 to 0.55. Ranked #136 of 1,352 Window families, it carries 360 Most Efficient options.

Does Windsor Windows and Doors Pinnacle Clad Radius Direct Glaze qualify for the ENERGY STAR Northern Zone?

Cold-climate buyers get 498 compliant Northern packages inside Pinnacle Clad Radius Direct Glaze, reaching down to U 0.15. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.

What conductive BTU/hr difference separates Pinnacle Clad Radius Direct Glaze from the 0.22 Northern rule?

At U 0.15, a standard 3x5 ft (15 sq ft) Pinnacle Clad Radius Direct Glaze opening transfers 90.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -42.0 BTU/hr difference.

When should a buyer skip Windsor Windows and Doors Pinnacle Clad Radius Direct Glaze and compare alternatives?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Pinnacle Clad Radius Direct Glaze options exceeding U 0.22. Verify whether your municipal code restricts Wood frames in wildfire or historic zones.

Is Pinnacle Clad Radius Direct Glaze suitable for sunbelt cooling-dominated homes?

Warm-climate homeowners have 848 Southern-approved options within Pinnacle Clad Radius Direct Glaze spanning SHGC down to 0.13. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

How many Windsor Windows and Doors Pinnacle Clad Radius Direct Glaze variants earn ENERGY STAR Most Efficient?

Within Pinnacle Clad Radius Direct Glaze, 28.4% (360 of 1,266) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

Do 2026 Pinnacle Clad Radius Direct Glaze installations qualify for IRS Section 25C tax credits?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Pinnacle Clad Radius Direct Glaze retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

How do building inspectors verify Pinnacle Clad Radius Direct Glaze glass specs on job sites?

Match the NFRC thermal sticker for code WIN and line WIN-N-112 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Windsor Windows and Doors Pinnacle Clad Radius Direct Glaze come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros