Kolbe and Kolbe Millwork Co., Inc — Ultra Double Hung Studio Sterling · Picture Window
EPA ENERGY STAR Version 7.0 certifies 845 variants inside Kolbe and Kolbe Millwork Co., Inc Ultra Double Hung Studio Sterling, combining Wood frame construction with U-Factors spanning 0.15 to 0.32 and SHGC 0.09 to 0.47. Qualifying for Northern, North-Central, South-Central, Southern, this Picture Window family places #136 of 1,352 among 1,352 Window families and posts 0.06 Btu/hr·ft²·°F more insulating than the 0.21 Btu/hr·ft²·°F median among Wood peers.
- Min U-Factor
- 0.15
- SHGC Range
- 0.09-0.47
- Certified Options
- 845
- Category Standing
- #136 of 1,352
How does Kolbe and Kolbe Millwork Co., Inc Ultra Double Hung Studio Sterling compare thermally against Window peers?
Kolbe and Kolbe Millwork Co., Inc Ultra Double Hung Studio Sterling achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Glazing breadth across Ultra Double Hung Studio Sterling spans 845 NFRC test records (KKM), ranking #136 of 1,352 Window families (tied with 113 others at 0.15, more insulating than 81.6% of Window lines, top 18.4%). Its 0.15 thermal floor compares at -0.06 against the Wood median (0.21).
Climate coverage for Kolbe and Kolbe Millwork Co., Inc Ultra Double Hung Studio Sterling spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 530 configurations meet ENERGY STAR Most Efficient criteria while 280 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Data provenance links certification 2026-09-25 and FENSTAR license 2018-02-20 inside EPA Version 7.0 tables. Heat transfer computes to 90.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 845 certified glazing combinations for Ultra Double Hung Studio Sterling (NFRC KKM) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 280 packages (212 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 523 packages (512 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 507 packages (400 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 709 packages (400 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Windsor Windows and Doors — Pinnacle Clad Radius Direct Glaze | Wood | 0.15 | 0.13 | 1,266 |
| Lepage Millwork — Fixed XL Hung | Wood | 0.15 | 0.16 | 154 |
| Marvin — Elevate Direct Glaze | Wood | 0.15 | 0.13 | 2,250 |
| Andersen Corporation — 400 Series Tilt-Wash Double-Hung Transom Full-Frame Window | Wood | 0.15 | 0.13 | 2,446 |
| Pella Corporation — Architect Wood Fixed Casement | Wood | 0.15 | 0.11 | 2,468 |
What other certified series does Kolbe and Kolbe Millwork Co., Inc produce?
Compare other active Kolbe and Kolbe Millwork Co., Inc certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
Heritage Casement Picture Sash Set
U-Factor 0.11–0.31 · 1,234 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kolbe and Kolbe Millwork Co., Inc Ultra Double Hung Studio Sterling appear below.
What thermal performance numbers separate Kolbe and Kolbe Millwork Co., Inc Ultra Double Hung Studio Sterling from peers?
Built with Wood framing in Fixed Window (FIXD) style, Kolbe and Kolbe Millwork Co., Inc Ultra Double Hung Studio Sterling offers 845 Version 7.0 configurations from U 0.15 up to 0.32, posting -0.05 against the Window median of 0.20 with 530 Most Efficient picks.
Which glazing options in Kolbe and Kolbe Millwork Co., Inc Ultra Double Hung Studio Sterling meet Northern climate limits?
Yes. 280 packages in Kolbe and Kolbe Millwork Co., Inc Ultra Double Hung Studio Sterling clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.
What BTU/hr heat transfer results from Ultra Double Hung Studio Sterling's 0.15 minimum U-Factor?
Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Ultra Double Hung Studio Sterling at U 0.15 conducts 90.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.
Who should NOT choose Kolbe and Kolbe Millwork Co., Inc Ultra Double Hung Studio Sterling for a residential project?
Cold-climate owners needing prescriptive U <= 0.22 should pass on Ultra Double Hung Studio Sterling options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.
Does Ultra Double Hung Studio Sterling meet Southern hot-climate SHGC caps (<= 0.23)?
Exactly 709 Ultra Double Hung Studio Sterling options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.09 rather than higher 0.47 glass.
Which package tier in Ultra Double Hung Studio Sterling holds Most Efficient recognition?
EPA lists 530 Most Efficient options (62.7% share) inside Kolbe and Kolbe Millwork Co., Inc Ultra Double Hung Studio Sterling, out of 845 total Version 7.0 entries.
What federal compliance checks govern 2026 Ultra Double Hung Studio Sterling window swaps?
Tax rules ended Section 25C on December 31, 2025, shifting 2026 Kolbe and Kolbe Millwork Co., Inc upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.
Where are NFRC and IGCC identification marks located on Ultra Double Hung Studio Sterling?
Match the NFRC thermal sticker for code KKM and line KKM-N-281 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Kolbe and Kolbe Millwork Co., Inc Ultra Double Hung Studio Sterling come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)