Lepage Millwork — Fixed XL Hung · Picture Window
Lepage Millwork Fixed XL Hung is a Picture Window assembly with a Wood frame that reaches a minimum U-Factor of 0.15 across 154 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #136 of 1,352 in Window, its thermal floor is 0.05 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.16 to 0.51.
- Min U-Factor
- 0.15
- SHGC Range
- 0.16-0.51
- Certified Options
- 154
- Category Standing
- #136 of 1,352
How does Lepage Millwork Fixed XL Hung compare thermally against Window peers?
Lepage Millwork Fixed XL Hung achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Within the Wood cohort (0.21 median U-Factor), Fixed XL Hung reaches 0.15 on its lowest-conductivity package — #34 of 408 in Wood, tied with 30 others at 0.15, more insulating than 84.3% of Wood lines, top 15.7% (-0.06 vs Wood peers). Pairing NFRC ID LEP across multi-pane fills shifts U-Factor from 0.32 down toward 0.15.
Regional qualification covers Northern, North-Central, South-Central, Southern. 41 configurations meet ENERGY STAR Most Efficient criteria while 66 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 90.0 BTU/hr (-31.8% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2024-10-24.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 154 certified glazing combinations for Fixed XL Hung (NFRC LEP) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 66 packages (18 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 110 packages (19 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 80 packages (8 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 89 packages (26 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Kolbe and Kolbe Millwork Co., Inc — Heritage Traditional DH Direct Set Transom Wood | Wood | 0.15 | 0.12 | 513 |
| Kolbe and Kolbe Millwork Co., Inc — Ultra Double Hung Studio Sterling | Wood | 0.15 | 0.09 | 845 |
| Kolbe and Kolbe Millwork Co., Inc — Ultra Inswing Casement Fixed Picture | Wood | 0.15 | 0.09 | 853 |
| Kolbe and Kolbe Millwork Co., Inc — Heritage Sterling Double Hung | Wood | 0.15 | 0.09 | 857 |
| Kolbe and Kolbe Millwork Co., Inc — Heritage Casement | Wood | 0.15 | 0.09 | 1,084 |
What other certified series does Lepage Millwork produce?
Compare other active Lepage Millwork certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
MultiSlide Patio Door (Wood and Clad)
U-Factor 0.18–0.28 · 132 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Lepage Millwork Fixed XL Hung appear below.
How efficient is Lepage Millwork Fixed XL Hung compared with peer Window models?
Lepage Millwork Fixed XL Hung spans 154 certified configurations with U-Factors between 0.15 and 0.32 and SHGC values from 0.16 to 0.51. Ranked #136 of 1,352 Window families, it carries 41 Most Efficient options.
How does Lepage Millwork Fixed XL Hung satisfy Version 7.0 Northern criteria?
Cold-climate buyers get 66 compliant Northern packages inside Fixed XL Hung, reaching down to U 0.15. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.
How much winter heat loss does Fixed XL Hung conduct across a 15 sq ft opening?
At U 0.15, a standard 3x5 ft (15 sq ft) Fixed XL Hung opening transfers 90.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -42.0 BTU/hr difference.
Which situations make Fixed XL Hung the wrong window or door choice?
Cold-climate owners needing prescriptive U <= 0.22 should pass on Fixed XL Hung options exceeding U 0.22. Additionally, do not order Fixed Window (FIXD) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).
Can you install Lepage Millwork Fixed XL Hung in Southern or South-Central zones?
Yes. 89 Southern-certified options inside Lepage Millwork Fixed XL Hung satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.51 SHGC on west-facing glass to avoid excess afternoon solar gain.
Which package tier in Fixed XL Hung holds Most Efficient recognition?
Within Fixed XL Hung, 26.6% (41 of 154) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.
Can homeowners claim Form 5695 credits on Lepage Millwork Fixed XL Hung in 2026?
IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 Fixed XL Hung installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.
Where are NFRC and IGCC identification marks located on Fixed XL Hung?
Match the NFRC thermal sticker for code LEP and line LEP-M-73 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Lepage Millwork Fixed XL Hung come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)