Kolbe and Kolbe Millwork Co., Inc — Heritage Sterling Double Hung · Double Hung
Kolbe and Kolbe Millwork Co., Inc Heritage Sterling Double Hung is a Double Hung assembly with a Wood frame that reaches a minimum U-Factor of 0.15 across 857 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #136 of 1,352 in Window, its thermal floor is 0.05 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.09 to 0.45.
- Min U-Factor
- 0.15
- SHGC Range
- 0.09-0.45
- Certified Options
- 857
- Category Standing
- #136 of 1,352
How does Kolbe and Kolbe Millwork Co., Inc Heritage Sterling Double Hung compare thermally against Window peers?
Kolbe and Kolbe Millwork Co., Inc Heritage Sterling Double Hung achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Within the Wood cohort (0.21 median U-Factor), Heritage Sterling Double Hung reaches 0.15 on its lowest-conductivity package — #34 of 408 in Wood, tied with 30 others at 0.15, more insulating than 84.3% of Wood lines, top 15.7% (-0.06 vs Wood peers). Pairing NFRC ID KKM across multi-pane fills shifts U-Factor from 0.32 down toward 0.15.
Climate coverage for Kolbe and Kolbe Millwork Co., Inc Heritage Sterling Double Hung spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 424 configurations meet ENERGY STAR Most Efficient criteria while 196 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Registry history records EPA FENSTAR licensing on 2018-02-20 and v7.0 data certification on 2026-02-09. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.15 conducts 90.0 BTU/hr (-42.0 BTU/hr vs the 0.22 ceiling).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 857 certified glazing combinations for Heritage Sterling Double Hung (NFRC KKM) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 196 packages (134 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 465 packages (424 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 550 packages (342 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 761 packages (342 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Windsor Windows and Doors — Pinnacle Clad Radius Direct Glaze | Wood | 0.15 | 0.13 | 1,266 |
| Lepage Millwork — Fixed XL Hung | Wood | 0.15 | 0.16 | 154 |
| Marvin — Elevate Direct Glaze | Wood | 0.15 | 0.13 | 2,250 |
| Andersen Corporation — 400 Series Tilt-Wash Double-Hung Transom Full-Frame Window | Wood | 0.15 | 0.13 | 2,446 |
| Pella Corporation — Architect Wood Fixed Casement | Wood | 0.15 | 0.11 | 2,468 |
What other certified series does Kolbe and Kolbe Millwork Co., Inc produce?
Compare other active Kolbe and Kolbe Millwork Co., Inc certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
Heritage Casement Picture Sash Set
U-Factor 0.11–0.31 · 1,234 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kolbe and Kolbe Millwork Co., Inc Heritage Sterling Double Hung appear below.
What thermal performance numbers separate Kolbe and Kolbe Millwork Co., Inc Heritage Sterling Double Hung from peers?
Across 857 tested NFRC glazing configurations, Kolbe and Kolbe Millwork Co., Inc Heritage Sterling Double Hung with Wood framing and Double-Hung (VSDH) style reaches a 0.15 minimum U-Factor and 0.09-0.45 SHGC band. It places #136 among 1,352 Window series—top 18.4%.
Can homeowners install Heritage Sterling Double Hung in cold Northern ENERGY STAR counties?
Cold-climate buyers get 196 compliant Northern packages inside Heritage Sterling Double Hung, reaching down to U 0.15. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.
How does a 3x5 ft Heritage Sterling Double Hung window perform under a 40 deg F temperature drop?
Using NFRC KKM U-Factor 0.15, a 15 sq ft Double-Hung (VSDH) assembly conducts 90.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-42.0 BTU/hr margin).
What are the practical limitations of specifying Heritage Sterling Double Hung?
Cold-climate owners needing prescriptive U <= 0.22 should pass on Heritage Sterling Double Hung options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.
What Southern ENERGY STAR v7.0 options exist in Heritage Sterling Double Hung?
Warm-climate homeowners have 761 Southern-approved options within Heritage Sterling Double Hung spanning SHGC down to 0.09. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.
Does Heritage Sterling Double Hung carry EPA Most Efficient certification across its lineup?
Within Heritage Sterling Double Hung, 49.5% (424 of 857) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.
How do the 25C sunset and pre-1978 Lead RRP rules affect Heritage Sterling Double Hung?
IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 Heritage Sterling Double Hung installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.
How do building inspectors verify Heritage Sterling Double Hung glass specs on job sites?
Confirm both the paper NFRC label and permanent corner glass etch match line KKM-N-113 and NFRC ID KKM before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Kolbe and Kolbe Millwork Co., Inc Heritage Sterling Double Hung come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)