Skip to main content
Window · Wood Frame NFRC LEP · Product Line LEP-M-77 ENERGY STAR Most Efficient Eligible

Lepage Millwork — Wood Direct Set (TF-100) · Picture Window

Across 10 Lepage Millwork certified families, Wood Direct Set (TF-100) supplies 90 Picture Window configurations starting at 0.14 U-Factor and 0.19 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.60 SHGC. Its thermal floor ranks #72 of 1,352 category entries—0.06 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.14
SHGC Range
0.19-0.60
Certified Options
90
Category Standing
#72 of 1,352

How does Lepage Millwork Wood Direct Set (TF-100) compare thermally against Window peers?

Lepage Millwork Wood Direct Set (TF-100) achieves a 0.14 thermal floor across Window lines, placing #72 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Wood Direct Set (TF-100)Histogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing Wood Direct Set (TF-100) (U 0.14).249<=0.15This model: U 0.143140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Wood Direct Set (TF-100) Cohort StandingMin U-Factor 0.14 stands at rank #72 of 1,352, outperforming 90.0% of peers.Min U-Factor 0.14Rank #72 of 1,352 (90.0% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 10 certified Lepage Millwork series, this Picture Window offers a 0.18 U-Factor adjustment span between 0.32 entry options and 0.14 top-performing glazing. Category standing is #72/1,352 (tied with 63 others at 0.14, more insulating than 90.0% of Window lines, top 10.0%).

Mapping NFRC SHGC values (0.19 to 0.60) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 27 configurations meet ENERGY STAR Most Efficient criteria while 46 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.14 U-Factor yields 84.0 BTU/hr transfer (-48.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-01-10 licensing and 2026-07-17 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 90 certified glazing combinations for Wood Direct Set (TF-100) (NFRC LEP) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 46 packages (20 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 55 packages (18 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 35 packages (5 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 42 packages (10 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.14 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Lepage Millwork produce?

Compare other active Lepage Millwork certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Lepage Millwork Wood Direct Set (TF-100) appear below.

What U-Factor and SHGC range does Lepage Millwork Wood Direct Set (TF-100) achieve?

Lepage Millwork Wood Direct Set (TF-100) spans 90 certified configurations with U-Factors between 0.14 and 0.32 and SHGC values from 0.19 to 0.60. Ranked #72 of 1,352 Window families, it carries 27 Most Efficient options.

Does Lepage Millwork Wood Direct Set (TF-100) qualify for the ENERGY STAR Northern Zone?

Cold-climate buyers get 46 compliant Northern packages inside Wood Direct Set (TF-100), reaching down to U 0.14. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.

How do you calculate winter heat conduction for Lepage Millwork Wood Direct Set (TF-100)?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Wood Direct Set (TF-100) at U 0.14 conducts 84.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

Who should NOT choose Lepage Millwork Wood Direct Set (TF-100) for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Wood Direct Set (TF-100) options exceeding U 0.22. Additionally, do not order Fixed Window (FIXD) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

What Southern ENERGY STAR v7.0 options exist in Wood Direct Set (TF-100)?

Across Northern, North-Central, South-Central, Southern, 42 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Lepage Millwork Wood Direct Set (TF-100), while total line SHGC reaches 0.60 in colder packages.

Which package tier in Wood Direct Set (TF-100) holds Most Efficient recognition?

No. Exactly 27 of 90 configurations (30.0%) earn ENERGY STAR Most Efficient status in Wood Direct Set (TF-100); the remaining standard v7.0 options pass base zone limits only.

How do the 25C sunset and pre-1978 Lead RRP rules affect Wood Direct Set (TF-100)?

Any Wood Direct Set (TF-100) purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How do building inspectors verify Wood Direct Set (TF-100) glass specs on job sites?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code LEP and product line LEP-M-77, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Lepage Millwork Wood Direct Set (TF-100) come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros