Skip to main content
Door · Wood Frame NFRC LEP · Product Line LEP-M-58

Lepage Millwork — Bi-Fold Door · Swinging Entry Door (Double)

Lepage Millwork Bi-Fold Door is a Swinging Entry Door, Double assembly with a Wood frame that reaches a minimum U-Factor of 0.19 across 122 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #94 of 268 in Door, its thermal floor is 0.02 Btu/hr·ft²·°F more insulating than the 0.21 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.12 to 0.39.

Min U-Factor
0.19
SHGC Range
0.12-0.39
Certified Options
122
Category Standing
#94 of 268

How does Lepage Millwork Bi-Fold Door compare thermally against Door peers?

Lepage Millwork Bi-Fold Door achieves a 0.19 thermal floor across Door lines, placing #94 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. Bi-Fold DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing Bi-Fold Door (U 0.19).28<=0.15650.16-0.18510.19-0.21This model: U 0.19710.22-0.24430.25-0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

Bi-Fold Door Cohort StandingMin U-Factor 0.19 stands at rank #94 of 268, outperforming 57.1% of peers.Min U-Factor 0.19Rank #94 of 268 (57.1% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Lepage Millwork Bi-Fold Door standing at #94 of 268 certified Door product series, tied with 21 others at 0.19, more insulating than 57.1% of Door lines, top 42.9%. Comparing Wood profiles alone (median 0.21) shows -0.02 before selecting Low-E tiers.

Regional qualification covers Northern, North-Central, South-Central, Southern. 92 combinations qualify in the Northern Zone alongside 99 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Registry history records EPA FENSTAR licensing on 2018-01-10 and v7.0 data certification on 2025-12-19. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.19 conducts 114.0 BTU/hr (-18.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 122 certified glazing combinations for Bi-Fold Door (NFRC LEP) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 92 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 92 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 99 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 99 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Novatech Group — 650 Patio Door Wood 0.19 0.10 354
Kolbe and Kolbe Millwork Co., Inc — Ultra/VistaLuxe Exterior Folding Door Wood 0.19 0.08 1,039
Marvin — Ultimate MultiSlide Door Wood 0.19 0.10 2,129
Kolbe and Kolbe Millwork Co., Inc — Ultra/VistaLuxe Outswing Door Wood 0.19 0.05 3,062
Marvin — Ultimate Bi-Fold Door Wood 0.19 0.08 5,171

What other certified series does Lepage Millwork produce?

Compare other active Lepage Millwork certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Lepage Millwork Bi-Fold Door appear below.

How efficient is Lepage Millwork Bi-Fold Door compared with peer Door models?

Across 122 tested NFRC glazing configurations, Lepage Millwork Bi-Fold Door with Wood framing and Hinged Patio French Door (DDFR) style reaches a 0.19 minimum U-Factor and 0.12-0.39 SHGC band. It places #94 among 268 Door series—top 42.9%.

Which glazing options in Lepage Millwork Bi-Fold Door meet Northern climate limits?

Prescriptive Northern compliance covers 92 Bi-Fold Door packages (U floor 0.19, SHGC >= 0.17). Because the complete series stretches up to U 0.28, specify the cold-climate glass code explicitly.

What conductive BTU/hr difference separates Bi-Fold Door from the 0.22 Northern rule?

Using NFRC LEP U-Factor 0.19, a 15 sq ft Hinged Patio French Door (DDFR) assembly conducts 114.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-18.0 BTU/hr margin).

Which situations make Bi-Fold Door the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Bi-Fold Door options exceeding U 0.22. Additionally, do not order Hinged Patio French Door (DDFR) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Is Bi-Fold Door suitable for sunbelt cooling-dominated homes?

Yes. 99 Southern-certified options inside Lepage Millwork Bi-Fold Door satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.39 SHGC on west-facing glass to avoid excess afternoon solar gain.

Which package tier in Bi-Fold Door holds Most Efficient recognition?

All 122 Bi-Fold Door listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

Can homeowners claim Form 5695 credits on Lepage Millwork Bi-Fold Door in 2026?

Any Bi-Fold Door purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How can homeowners confirm delivered Lepage Millwork Bi-Fold Door units match permits?

Verify NFRC ID LEP and series LEP-M-58 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Lepage Millwork Bi-Fold Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros