Skip to main content
Window · Wood Frame NFRC LEP · Product Line LEP-M-63 ENERGY STAR Most Efficient Eligible

Lepage Millwork — XL-300 & XL-200 Hung · Double Hung

EPA ENERGY STAR Version 7.0 certifies 108 variants inside Lepage Millwork XL-300 & XL-200 Hung, combining Wood frame construction with U-Factors spanning 0.17 to 0.32 and SHGC 0.14 to 0.50. Qualifying for Northern, North-Central, South-Central, Southern, this Double Hung family places #362 of 1,352 among 1,352 Window families and posts 0.04 Btu/hr·ft²·°F more insulating than the 0.21 Btu/hr·ft²·°F median among Wood peers.

Min U-Factor
0.17
SHGC Range
0.14-0.50
Certified Options
108
Category Standing
#362 of 1,352

How does Lepage Millwork XL-300 & XL-200 Hung compare thermally against Window peers?

Lepage Millwork XL-300 & XL-200 Hung achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. XL-300 & XL-200 HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing XL-300 & XL-200 Hung (U 0.17).249<=0.153140.16-0.18This model: U 0.172670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

XL-300 & XL-200 Hung Cohort StandingMin U-Factor 0.17 stands at rank #362 of 1,352, outperforming 64.8% of peers.Min U-Factor 0.17Rank #362 of 1,352 (64.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Lepage Millwork XL-300 & XL-200 Hung at rank #362 of 1,352 (tied with 114 others at 0.17, more insulating than 64.8% of Window lines, top 35.2%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.14-0.50 band.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 20 configurations meet ENERGY STAR Most Efficient criteria while 32 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 102.0 BTU/hr (-22.7% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2025-12-08.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 108 certified glazing combinations for XL-300 & XL-200 Hung (NFRC LEP) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 32 packages (11 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 61 packages (18 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 65 packages (16 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 73 packages (18 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Lepage Millwork produce?

Compare other active Lepage Millwork certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Lepage Millwork XL-300 & XL-200 Hung appear below.

Where does Lepage Millwork XL-300 & XL-200 Hung stand thermally among ENERGY STAR Window lines?

Testing puts Lepage Millwork XL-300 & XL-200 Hung at rank #362 of 1,352 Window entries with U 0.17 to 0.32 across 108 configurations. Solar heat gain ranges between 0.14 and 0.50 across Northern, North-Central, South-Central, Southern.

Which glazing options in Lepage Millwork XL-300 & XL-200 Hung meet Northern climate limits?

Yes. 32 packages in Lepage Millwork XL-300 & XL-200 Hung clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.

How do you calculate winter heat conduction for Lepage Millwork XL-300 & XL-200 Hung?

Using NFRC LEP U-Factor 0.17, a 15 sq ft Double-Hung (VSDH) assembly conducts 102.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-30.0 BTU/hr margin).

What homeowner profiles are a poor match for Lepage Millwork XL-300 & XL-200 Hung?

Cold-climate owners needing prescriptive U <= 0.22 should pass on XL-300 & XL-200 Hung options exceeding U 0.22. Additionally, do not order Double-Hung (VSDH) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Does XL-300 & XL-200 Hung meet Southern hot-climate SHGC caps (<= 0.23)?

Yes, XL-300 & XL-200 Hung holds 73 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.14 SHGC in cooling climates.

Which package tier in XL-300 & XL-200 Hung holds Most Efficient recognition?

Only 20 options out of 108 (18.5%) meet tighter Most Efficient U-Factor and SHGC thresholds in Lepage Millwork XL-300 & XL-200 Hung, usually requiring triple-pane or upgraded Low-E coatings.

Do 2026 XL-300 & XL-200 Hung installations qualify for IRS Section 25C tax credits?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 XL-300 & XL-200 Hung installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

Where are NFRC and IGCC identification marks located on XL-300 & XL-200 Hung?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code LEP and product line LEP-M-63, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Lepage Millwork XL-300 & XL-200 Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros