Lepage Millwork — Wood Fixed Casement C-100 · Picture Window
Lepage Millwork Wood Fixed Casement C-100 is a Picture Window assembly with a Wood frame that reaches a minimum U-Factor of 0.16 across 282 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #250 of 1,352 in Window, its thermal floor is 0.04 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.17 to 0.53.
- Min U-Factor
- 0.16
- SHGC Range
- 0.17-0.53
- Certified Options
- 282
- Category Standing
- #250 of 1,352
How does Lepage Millwork Wood Fixed Casement C-100 compare thermally against Window peers?
Lepage Millwork Wood Fixed Casement C-100 achieves a 0.16 thermal floor across Window lines, placing #250 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Within the Wood cohort (0.21 median U-Factor), Wood Fixed Casement C-100 reaches 0.16 on its lowest-conductivity package — #65 of 408 in Wood, tied with 22 others at 0.16, more insulating than 78.7% of Wood lines, top 21.3% (-0.05 vs Wood peers). Pairing NFRC ID LEP across multi-pane fills shifts U-Factor from 0.32 down toward 0.16.
Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 46 configurations meet ENERGY STAR Most Efficient criteria while 86 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.16 U-Factor yields 96.0 BTU/hr transfer (-36.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-01-10 licensing and 2026-07-17 certification.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 282 certified glazing combinations for Wood Fixed Casement C-100 (NFRC LEP) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 86 packages (30 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 141 packages (40 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 133 packages (20 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 172 packages (24 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Kolbe and Kolbe Millwork Co., Inc — Ultra Double Hung Direct Set | Wood | 0.16 | 0.12 | 574 |
| Marvin — Elevate Casement Picture | Wood | 0.16 | 0.13 | 657 |
| Kolbe and Kolbe Millwork Co., Inc — Heritage Outswing Entrance Door Sash Set Transom Wood | Wood | 0.16 | 0.10 | 665 |
| Kolbe and Kolbe Millwork Co., Inc — Heritage Old World Classic Double Hung | Wood | 0.16 | 0.08 | 818 |
| Weather Shield Mfg., Inc. — 8307/1311 Direct Set | Wood | 0.16 | 0.13 | 906 |
What other certified series does Lepage Millwork produce?
Compare other active Lepage Millwork certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
MultiSlide Patio Door (Wood and Clad)
U-Factor 0.18–0.28 · 132 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Lepage Millwork Wood Fixed Casement C-100 appear below.
How efficient is Lepage Millwork Wood Fixed Casement C-100 compared with peer Window models?
Built with Wood framing in Fixed Window (FIXD) style, Lepage Millwork Wood Fixed Casement C-100 offers 282 Version 7.0 configurations from U 0.16 up to 0.32, posting -0.04 against the Window median of 0.20 with 46 Most Efficient picks.
Is Wood Fixed Casement C-100 approved for Northern Zone heating climates?
Cold-climate buyers get 86 compliant Northern packages inside Wood Fixed Casement C-100, reaching down to U 0.16. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.
What BTU/hr heat transfer results from Wood Fixed Casement C-100's 0.16 minimum U-Factor?
At U 0.16, a standard 3x5 ft (15 sq ft) Wood Fixed Casement C-100 opening transfers 96.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -36.0 BTU/hr difference.
Who should NOT choose Lepage Millwork Wood Fixed Casement C-100 for a residential project?
Skip Wood Fixed Casement C-100 if local historic preservation boards prohibit Wood profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Wood Fixed Casement C-100 options exceeding U 0.22.
What Southern ENERGY STAR v7.0 options exist in Wood Fixed Casement C-100?
Across Northern, North-Central, South-Central, Southern, 172 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Lepage Millwork Wood Fixed Casement C-100, while total line SHGC reaches 0.53 in colder packages.
Are all 282 Wood Fixed Casement C-100 configurations ENERGY STAR Most Efficient?
Only 46 options out of 282 (16.3%) meet tighter Most Efficient U-Factor and SHGC thresholds in Lepage Millwork Wood Fixed Casement C-100, usually requiring triple-pane or upgraded Low-E coatings.
Do 2026 Wood Fixed Casement C-100 installations qualify for IRS Section 25C tax credits?
Any Wood Fixed Casement C-100 purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.
Where are NFRC and IGCC identification marks located on Wood Fixed Casement C-100?
Leave the temporary NFRC label intact until inspection to confirm manufacturer code LEP and product line LEP-M-76, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Lepage Millwork Wood Fixed Casement C-100 come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)