Skip to main content
Door · Wood Frame NFRC KKM · Product Line KKM-N-282

Kolbe and Kolbe Millwork Co., Inc — Ultra/VistaLuxe Exterior Folding Door · Swinging Entry Door (Double)

Kolbe and Kolbe Millwork Co., Inc Ultra/VistaLuxe Exterior Folding Door is a Swinging Entry Door, Double assembly with a Wood frame that reaches a minimum U-Factor of 0.19 across 1,039 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #94 of 268 in Door, its thermal floor is 0.02 Btu/hr·ft²·°F more insulating than the 0.21 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.08 to 0.37.

Min U-Factor
0.19
SHGC Range
0.08-0.37
Certified Options
1,039
Category Standing
#94 of 268

How does Kolbe and Kolbe Millwork Co., Inc Ultra/VistaLuxe Exterior Folding Door compare thermally against Door peers?

Kolbe and Kolbe Millwork Co., Inc Ultra/VistaLuxe Exterior Folding Door achieves a 0.19 thermal floor across Door lines, placing #94 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. Ultra/VistaLuxe Exterior Folding DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing Ultra/VistaLuxe Exterior Folding Door (U 0.19).28<=0.15650.16-0.18510.19-0.21This model: U 0.19710.22-0.24430.25-0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

Ultra/VistaLuxe Exterior Folding Door Cohort StandingMin U-Factor 0.19 stands at rank #94 of 268, outperforming 57.1% of peers.Min U-Factor 0.19Rank #94 of 268 (57.1% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 57 certified Kolbe and Kolbe Millwork Co., Inc series, this Swinging Entry Door, Double offers a 0.09 U-Factor adjustment span between 0.28 entry options and 0.19 top-performing glazing. Category standing is #94/268 (tied with 21 others at 0.19, more insulating than 57.1% of Door lines, top 42.9%).

Climate coverage for Kolbe and Kolbe Millwork Co., Inc Ultra/VistaLuxe Exterior Folding Door spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 936 combinations qualify in the Northern Zone alongside 855 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Registry history records EPA FENSTAR licensing on 2018-02-20 and v7.0 data certification on 2026-06-18. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.19 conducts 114.0 BTU/hr (-18.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,039 certified glazing combinations for Ultra/VistaLuxe Exterior Folding Door (NFRC KKM) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 936 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 936 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 855 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 855 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Novatech Group — 650 Patio Door Wood 0.19 0.10 354
Lepage Millwork — Bi-Fold Door Wood 0.19 0.12 122
Marvin — Ultimate MultiSlide Door Wood 0.19 0.10 2,129
Marvin — Ultimate Bi-Fold Door Wood 0.19 0.08 5,171
JELD-WEN, inc. — Premium Fiberglass Architectural Series Door Steel / Wood 0.19 0.03 946

What other certified series does Kolbe and Kolbe Millwork Co., Inc produce?

Compare other active Kolbe and Kolbe Millwork Co., Inc certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kolbe and Kolbe Millwork Co., Inc Ultra/VistaLuxe Exterior Folding Door appear below.

Where does Kolbe and Kolbe Millwork Co., Inc Ultra/VistaLuxe Exterior Folding Door stand thermally among ENERGY STAR Door lines?

Built with Wood framing in Hinged Patio French Door (DDFR) style, Kolbe and Kolbe Millwork Co., Inc Ultra/VistaLuxe Exterior Folding Door offers 1,039 Version 7.0 configurations from U 0.19 up to 0.28, posting -0.02 against the Door median of 0.21 with 0 Most Efficient picks.

Can homeowners install Ultra/VistaLuxe Exterior Folding Door in cold Northern ENERGY STAR counties?

Prescriptive Northern compliance covers 936 Ultra/VistaLuxe Exterior Folding Door packages (U floor 0.19, SHGC >= 0.17). Because the complete series stretches up to U 0.28, specify the cold-climate glass code explicitly.

What BTU/hr heat transfer results from Ultra/VistaLuxe Exterior Folding Door's 0.19 minimum U-Factor?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.19 U-Factor yields 114.0 BTU/hr conductive transfer (-13.6% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

What homeowner profiles are a poor match for Kolbe and Kolbe Millwork Co., Inc Ultra/VistaLuxe Exterior Folding Door?

Skip Ultra/VistaLuxe Exterior Folding Door if local historic preservation boards prohibit Wood profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Ultra/VistaLuxe Exterior Folding Door options exceeding U 0.22.

How many Ultra/VistaLuxe Exterior Folding Door glazing packages pass Southern solar-heat rules?

Across Northern, North-Central, South-Central, Southern, 855 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Kolbe and Kolbe Millwork Co., Inc Ultra/VistaLuxe Exterior Folding Door, while total line SHGC reaches 0.37 in colder packages.

Does Ultra/VistaLuxe Exterior Folding Door carry EPA Most Efficient certification across its lineup?

Zero glazing builds inside Ultra/VistaLuxe Exterior Folding Door's 1,039 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

What 2026 federal tax credit and Lead RRP rules apply to Ultra/VistaLuxe Exterior Folding Door?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 Ultra/VistaLuxe Exterior Folding Door installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

How do building inspectors verify Ultra/VistaLuxe Exterior Folding Door glass specs on job sites?

Inspectors match the temporary NFRC sticker (U 0.19-0.28, SHGC 0.08-0.37) against permit drawings for line KKM-N-282. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Kolbe and Kolbe Millwork Co., Inc Ultra/VistaLuxe Exterior Folding Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros