Kolbe and Kolbe Millwork Co., Inc — Ultra Inswing Casement Fixed Picture · Picture Window
Across 57 Kolbe and Kolbe Millwork Co., Inc certified families, Ultra Inswing Casement Fixed Picture supplies 853 Picture Window configurations starting at 0.15 U-Factor and 0.09 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.46 SHGC. Its thermal floor ranks #136 of 1,352 category entries—0.05 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.15
- SHGC Range
- 0.09-0.46
- Certified Options
- 853
- Category Standing
- #136 of 1,352
How does Kolbe and Kolbe Millwork Co., Inc Ultra Inswing Casement Fixed Picture compare thermally against Window peers?
Kolbe and Kolbe Millwork Co., Inc Ultra Inswing Casement Fixed Picture achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Compared across 57 certified Kolbe and Kolbe Millwork Co., Inc series, this Picture Window offers a 0.17 U-Factor adjustment span between 0.32 entry options and 0.15 top-performing glazing. Category standing is #136/1,352 (tied with 113 others at 0.15, more insulating than 81.6% of Window lines, top 18.4%).
Climate coverage for Kolbe and Kolbe Millwork Co., Inc Ultra Inswing Casement Fixed Picture spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 524 configurations meet ENERGY STAR Most Efficient criteria while 240 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 90.0 BTU/hr (-31.8% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-02-20 and cert timestamp 2026-05-14.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 853 certified glazing combinations for Ultra Inswing Casement Fixed Picture (NFRC KKM) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 240 packages (166 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 539 packages (518 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 510 packages (407 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 723 packages (407 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Windsor Windows and Doors — Pinnacle Clad Radius Direct Glaze | Wood | 0.15 | 0.13 | 1,266 |
| Lepage Millwork — Fixed XL Hung | Wood | 0.15 | 0.16 | 154 |
| Marvin — Elevate Direct Glaze | Wood | 0.15 | 0.13 | 2,250 |
| Andersen Corporation — 400 Series Tilt-Wash Double-Hung Transom Full-Frame Window | Wood | 0.15 | 0.13 | 2,446 |
| Pella Corporation — Architect Wood Fixed Casement | Wood | 0.15 | 0.11 | 2,468 |
What other certified series does Kolbe and Kolbe Millwork Co., Inc produce?
Compare other active Kolbe and Kolbe Millwork Co., Inc certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
Heritage Casement Picture Sash Set
U-Factor 0.11–0.31 · 1,234 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kolbe and Kolbe Millwork Co., Inc Ultra Inswing Casement Fixed Picture appear below.
How efficient is Kolbe and Kolbe Millwork Co., Inc Ultra Inswing Casement Fixed Picture compared with peer Window models?
Across 853 tested NFRC glazing configurations, Kolbe and Kolbe Millwork Co., Inc Ultra Inswing Casement Fixed Picture with Wood framing and Fixed Window (FIXD) style reaches a 0.15 minimum U-Factor and 0.09-0.46 SHGC band. It places #136 among 1,352 Window series—top 18.4%.
How does Kolbe and Kolbe Millwork Co., Inc Ultra Inswing Casement Fixed Picture satisfy Version 7.0 Northern criteria?
Yes, 240 packages satisfy Northern ENERGY STAR Version 7.0 rules in Ultra Inswing Casement Fixed Picture. Pairing multi-pane insulation down to 0.15 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.
How does a 3x5 ft Ultra Inswing Casement Fixed Picture window perform under a 40 deg F temperature drop?
Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.15 U-Factor yields 90.0 BTU/hr conductive transfer (-31.8% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.
What are the practical limitations of specifying Ultra Inswing Casement Fixed Picture?
Cold-climate owners needing prescriptive U <= 0.22 should pass on Ultra Inswing Casement Fixed Picture options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.
Does Ultra Inswing Casement Fixed Picture meet Southern hot-climate SHGC caps (<= 0.23)?
Warm-climate homeowners have 723 Southern-approved options within Ultra Inswing Casement Fixed Picture spanning SHGC down to 0.09. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.
Which package tier in Ultra Inswing Casement Fixed Picture holds Most Efficient recognition?
EPA lists 524 Most Efficient options (61.4% share) inside Kolbe and Kolbe Millwork Co., Inc Ultra Inswing Casement Fixed Picture, out of 853 total Version 7.0 entries.
How do the 25C sunset and pre-1978 Lead RRP rules affect Ultra Inswing Casement Fixed Picture?
Any Ultra Inswing Casement Fixed Picture purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.
What permanent glass etch marks verify Ultra Inswing Casement Fixed Picture after sticker removal?
Match the NFRC thermal sticker for code KKM and line KKM-N-283 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Kolbe and Kolbe Millwork Co., Inc Ultra Inswing Casement Fixed Picture come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)