Kolbe and Kolbe Millwork Co., Inc — Ultra Casement Picture · Picture Window
Kolbe and Kolbe Millwork Co., Inc Ultra Casement Picture is a Picture Window assembly with a Wood frame that reaches a minimum U-Factor of 0.15 across 1,263 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #136 of 1,352 in Window, its thermal floor is 0.05 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.10 to 0.49.
- Min U-Factor
- 0.15
- SHGC Range
- 0.10-0.49
- Certified Options
- 1,263
- Category Standing
- #136 of 1,352
How does Kolbe and Kolbe Millwork Co., Inc Ultra Casement Picture compare thermally against Window peers?
Kolbe and Kolbe Millwork Co., Inc Ultra Casement Picture achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Relative to Window assemblies nationwide (median U 0.20), Ultra Casement Picture is 0.05 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Wood frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.15-0.32.
Regional qualification covers Northern, North-Central, South-Central, Southern. 903 configurations meet ENERGY STAR Most Efficient criteria while 469 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 90.0 BTU/hr (-31.8% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-02-20 and cert timestamp 2024-03-18.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 1,263 certified glazing combinations for Ultra Casement Picture (NFRC KKM) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 469 packages (364 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 930 packages (868 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 867 packages (688 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 1,038 packages (691 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Windsor Windows and Doors — Pinnacle Clad Radius Direct Glaze | Wood | 0.15 | 0.13 | 1,266 |
| Marvin — Elevate Direct Glaze | Wood | 0.15 | 0.13 | 2,250 |
| Lepage Millwork — Fixed XL Hung | Wood | 0.15 | 0.16 | 154 |
| Andersen Corporation — 400 Series Tilt-Wash Double-Hung Transom Full-Frame Window | Wood | 0.15 | 0.13 | 2,446 |
| Pella Corporation — Architect Wood Fixed Casement | Wood | 0.15 | 0.11 | 2,468 |
What other certified series does Kolbe and Kolbe Millwork Co., Inc produce?
Compare other active Kolbe and Kolbe Millwork Co., Inc certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
Heritage Casement Picture Sash Set
U-Factor 0.11–0.31 · 1,234 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kolbe and Kolbe Millwork Co., Inc Ultra Casement Picture appear below.
How efficient is Kolbe and Kolbe Millwork Co., Inc Ultra Casement Picture compared with peer Window models?
Kolbe and Kolbe Millwork Co., Inc Ultra Casement Picture spans 1,263 certified configurations with U-Factors between 0.15 and 0.32 and SHGC values from 0.10 to 0.49. Ranked #136 of 1,352 Window families, it carries 903 Most Efficient options.
Can homeowners install Ultra Casement Picture in cold Northern ENERGY STAR counties?
Yes. 469 packages in Kolbe and Kolbe Millwork Co., Inc Ultra Casement Picture clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.
How much winter heat loss does Ultra Casement Picture conduct across a 15 sq ft opening?
Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Ultra Casement Picture at U 0.15 conducts 90.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.
What homeowner profiles are a poor match for Kolbe and Kolbe Millwork Co., Inc Ultra Casement Picture?
Do not specify Ultra Casement Picture without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Ultra Casement Picture options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.
Does Ultra Casement Picture meet Southern hot-climate SHGC caps (<= 0.23)?
Across Northern, North-Central, South-Central, Southern, 1,038 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Kolbe and Kolbe Millwork Co., Inc Ultra Casement Picture, while total line SHGC reaches 0.49 in colder packages.
Which package tier in Ultra Casement Picture holds Most Efficient recognition?
EPA lists 903 Most Efficient options (71.5% share) inside Kolbe and Kolbe Millwork Co., Inc Ultra Casement Picture, out of 1,263 total Version 7.0 entries.
How do the 25C sunset and pre-1978 Lead RRP rules affect Ultra Casement Picture?
In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Ultra Casement Picture retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.
How do you cross-check NFRC KKM and product line KKM-N-270 on delivery?
Inspectors match the temporary NFRC sticker (U 0.15-0.32, SHGC 0.10-0.49) against permit drawings for line KKM-N-270. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Kolbe and Kolbe Millwork Co., Inc Ultra Casement Picture come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)