Skip to main content
Window · Wood Frame NFRC WIN · Product Line WIN-N-158 ENERGY STAR Most Efficient Eligible

Windsor Windows and Doors — Pinnacle Select Casement Picture · Picture Window

Windsor Windows and Doors Pinnacle Select Casement Picture is a Picture Window assembly with a Wood frame that reaches a minimum U-Factor of 0.17 across 1,248 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #362 of 1,352 in Window, its thermal floor is 0.03 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.11 to 0.48.

Min U-Factor
0.17
SHGC Range
0.11-0.48
Certified Options
1,248
Category Standing
#362 of 1,352

How does Windsor Windows and Doors Pinnacle Select Casement Picture compare thermally against Window peers?

Windsor Windows and Doors Pinnacle Select Casement Picture achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Pinnacle Select Casement PictureHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing Pinnacle Select Casement Picture (U 0.17).249<=0.153140.16-0.18This model: U 0.172670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Pinnacle Select Casement Picture Cohort StandingMin U-Factor 0.17 stands at rank #362 of 1,352, outperforming 64.8% of peers.Min U-Factor 0.17Rank #362 of 1,352 (64.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across Pinnacle Select Casement Picture spans 1,248 NFRC test records (WIN), ranking #362 of 1,352 Window families (tied with 114 others at 0.17, more insulating than 64.8% of Window lines, top 35.2%). Its 0.17 thermal floor compares at -0.04 against the Wood median (0.21).

Climate coverage for Windsor Windows and Doors Pinnacle Select Casement Picture spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 266 configurations meet ENERGY STAR Most Efficient criteria while 340 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 102.0 BTU/hr (-22.7% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2025-08-21.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,248 certified glazing combinations for Pinnacle Select Casement Picture (NFRC WIN) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 340 packages (132 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 583 packages (187 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 511 packages (80 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 919 packages (151 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Windsor Windows and Doors produce?

Compare other active Windsor Windows and Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Windsor Windows and Doors Pinnacle Select Casement Picture appear below.

What U-Factor and SHGC range does Windsor Windows and Doors Pinnacle Select Casement Picture achieve?

Built with Wood framing in Fixed Window (FIXD) style, Windsor Windows and Doors Pinnacle Select Casement Picture offers 1,248 Version 7.0 configurations from U 0.17 up to 0.32, posting -0.03 against the Window median of 0.20 with 266 Most Efficient picks.

Is Pinnacle Select Casement Picture approved for Northern Zone heating climates?

Yes. 340 packages in Windsor Windows and Doors Pinnacle Select Casement Picture clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.

What conductive BTU/hr difference separates Pinnacle Select Casement Picture from the 0.22 Northern rule?

At U 0.17, a standard 3x5 ft (15 sq ft) Pinnacle Select Casement Picture opening transfers 102.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -30.0 BTU/hr difference.

When should a buyer skip Windsor Windows and Doors Pinnacle Select Casement Picture and compare alternatives?

Skip Pinnacle Select Casement Picture if local historic preservation boards prohibit Wood profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Pinnacle Select Casement Picture options exceeding U 0.22.

What Southern ENERGY STAR v7.0 options exist in Pinnacle Select Casement Picture?

Yes. 919 Southern-certified options inside Windsor Windows and Doors Pinnacle Select Casement Picture satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.48 SHGC on west-facing glass to avoid excess afternoon solar gain.

Which package tier in Pinnacle Select Casement Picture holds Most Efficient recognition?

Only 266 options out of 1,248 (21.3%) meet tighter Most Efficient U-Factor and SHGC thresholds in Windsor Windows and Doors Pinnacle Select Casement Picture, usually requiring triple-pane or upgraded Low-E coatings.

What federal compliance checks govern 2026 Pinnacle Select Casement Picture window swaps?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How can homeowners confirm delivered Windsor Windows and Doors Pinnacle Select Casement Picture units match permits?

Verify NFRC ID WIN and series WIN-N-158 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Windsor Windows and Doors Pinnacle Select Casement Picture come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros