Skip to main content
Window · Vinyl Frame NFRC WCW · Product Line WCW-M-36 ENERGY STAR Most Efficient Eligible

Wincore Window Company, LLC — 5400 5400S 7700 9900 Series Vinyl Fixed Window Transom · Picture Window

Wincore Window Company, LLC 5400 5400S 7700 9900 Series Vinyl Fixed Window Transom is a Picture Window assembly with a Vinyl frame that reaches a minimum U-Factor of 0.17 across 1,833 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #362 of 1,352 in Window, its thermal floor is 0.03 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.14 to 0.49.

Min U-Factor
0.17
SHGC Range
0.14-0.49
Certified Options
1,833
Category Standing
#362 of 1,352

How does Wincore Window Company, LLC 5400 5400S 7700 9900 Series Vinyl Fixed Window Transom compare thermally against Window peers?

Wincore Window Company, LLC 5400 5400S 7700 9900 Series Vinyl Fixed Window Transom achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 5400 5400S 7700 9900 Series Vinyl Fixed Window TransomHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing 5400 5400S 7700 9900 Series Vinyl Fixed Window Transom (U 0.17).249<=0.153140.16-0.18This model: U 0.172670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

5400 5400S 7700 9900 Series Vinyl Fixed Window Transom Cohort StandingMin U-Factor 0.17 stands at rank #362 of 1,352, outperforming 64.8% of peers.Min U-Factor 0.17Rank #362 of 1,352 (64.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Wincore Window Company, LLC 5400 5400S 7700 9900 Series Vinyl Fixed Window Transom standing at #362 of 1,352 certified Window product series, tied with 114 others at 0.17, more insulating than 64.8% of Window lines, top 35.2%. Comparing Vinyl profiles alone (median 0.19) shows -0.02 before selecting Low-E tiers.

Regional qualification covers Northern, North-Central, South-Central, Southern. 218 configurations meet ENERGY STAR Most Efficient criteria while 176 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2018-08-23 and v7.0 data certification on 2025-01-23. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.17 conducts 102.0 BTU/hr (-30.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,833 certified glazing combinations for 5400 5400S 7700 9900 Series Vinyl Fixed Window Transom (NFRC WCW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 176 packages (28 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 695 packages (24 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 1,200 packages (12 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 1,728 packages (194 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
DRUTEX S.A. — IGLO 5 Classic Tilt Turn Vinyl 0.17 0.04 1,631
Windsor Windows and Doors — Next Dimension Casement Picture Vinyl 0.17 0.12 1,610
Vinylmax LLC — CP74 Picture Window Vinyl 0.17 0.14 1,603
Sierra Pacific Windows — Vinyl Direct Set Vinyl 0.17 0.12 2,077
Lindsay Windows — Pinnacle / Healthy Double Hung Vinyl 0.17 0.16 1,344

What other certified series does Wincore Window Company, LLC produce?

Compare other active Wincore Window Company, LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Wincore Window Company, LLC 5400 5400S 7700 9900 Series Vinyl Fixed Window Transom appear below.

How well does 5400 5400S 7700 9900 Series Vinyl Fixed Window Transom by Wincore Window Company, LLC insulate relative to Window benchmarks?

Across 1,833 tested NFRC glazing configurations, Wincore Window Company, LLC 5400 5400S 7700 9900 Series Vinyl Fixed Window Transom with Vinyl framing and Fixed Window (FIXD) style reaches a 0.17 minimum U-Factor and 0.14-0.49 SHGC band. It places #362 among 1,352 Window series—top 35.2%.

How does Wincore Window Company, LLC 5400 5400S 7700 9900 Series Vinyl Fixed Window Transom satisfy Version 7.0 Northern criteria?

Cold-climate buyers get 176 compliant Northern packages inside 5400 5400S 7700 9900 Series Vinyl Fixed Window Transom, reaching down to U 0.17. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.

How do you calculate winter heat conduction for Wincore Window Company, LLC 5400 5400S 7700 9900 Series Vinyl Fixed Window Transom?

At U 0.17, a standard 3x5 ft (15 sq ft) 5400 5400S 7700 9900 Series Vinyl Fixed Window Transom opening transfers 102.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -30.0 BTU/hr difference.

Which situations make 5400 5400S 7700 9900 Series Vinyl Fixed Window Transom the wrong window or door choice?

Skip 5400 5400S 7700 9900 Series Vinyl Fixed Window Transom if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on 5400 5400S 7700 9900 Series Vinyl Fixed Window Transom options exceeding U 0.22.

Is 5400 5400S 7700 9900 Series Vinyl Fixed Window Transom suitable for sunbelt cooling-dominated homes?

Exactly 1,728 5400 5400S 7700 9900 Series Vinyl Fixed Window Transom options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.14 rather than higher 0.49 glass.

Which package tier in 5400 5400S 7700 9900 Series Vinyl Fixed Window Transom holds Most Efficient recognition?

EPA lists 218 Most Efficient options (11.9% share) inside Wincore Window Company, LLC 5400 5400S 7700 9900 Series Vinyl Fixed Window Transom, out of 1,833 total Version 7.0 entries.

How do the 25C sunset and pre-1978 Lead RRP rules affect 5400 5400S 7700 9900 Series Vinyl Fixed Window Transom?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 5400 5400S 7700 9900 Series Vinyl Fixed Window Transom installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

How do you cross-check NFRC WCW and product line WCW-M-36 on delivery?

Match the NFRC thermal sticker for code WCW and line WCW-M-36 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Wincore Window Company, LLC 5400 5400S 7700 9900 Series Vinyl Fixed Window Transom come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros