Window · Vinyl Frame NFRC KOI · Product Line KOI-A-66 ENERGY STAR Most Efficient Eligible

Kohltech International, Ltd. — Select Casement · Casement Windows

Positioning #250/1,352 in certified Window, Kohltech International, Ltd. Select Casement pairs Vinyl frame construction with 50 glazing options rated between 0.17 and 0.46 SHGC across Northern, North-Central, South-Central, Southern. Across 21 certified Kohltech International, Ltd. product families, its thermal resistance spans 0.16 to 0.27 U-Factor and the line includes 19 ENERGY STAR Most Efficient packages (38.0% of line).

Min U-Factor
0.16
SHGC Range
0.17-0.46
Certified Options
50
Category Standing
#250 of 1,352

How does Kohltech International, Ltd. Select Casement compare thermally against Window peers?

Kohltech International, Ltd. Select Casement achieves a 0.16 thermal floor across Window lines, placing #250 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Select CasementHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing Select Casement (U 0.16).249<=0.153140.16-0.18This model: U 0.162670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Select Casement Cohort StandingMin U-Factor 0.16 stands at rank #250 of 1,352, outperforming 73.3% of peers.Min U-Factor 0.16Rank #250 of 1,352 (73.3% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Kohltech International, Ltd. Select Casement at rank #250 of 1,352 (tied with 111 others at 0.16, more insulating than 73.3% of Window lines, top 26.7%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.17-0.46 band.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 19 configurations meet ENERGY STAR Most Efficient criteria while 34 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2024-09-18 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 96.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 50 certified glazing combinations for Select Casement (NFRC KOI) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 34 packages (10 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 33 packages (14 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 23 packages (6 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 23 packages (11 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Kohltech International, Ltd. produce?

Compare other active Kohltech International, Ltd. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kohltech International, Ltd. Select Casement appear below.

How efficient is Kohltech International, Ltd. Select Casement compared with peer Window models?

EPA ENERGY STAR v7.0 records 50 configurations for Kohltech International, Ltd. Select Casement covering Northern, North-Central, South-Central, Southern, dropping down to U 0.16 versus a 0.20 Window median. Only 19 options earn Most Efficient status.

Is Select Casement approved for Northern Zone heating climates?

Yes. 34 packages in Kohltech International, Ltd. Select Casement clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.27.

What conductive BTU/hr difference separates Select Casement from the 0.22 Northern rule?

Using NFRC KOI U-Factor 0.16, a 15 sq ft Casement Single-Vent (CSSV) assembly conducts 96.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-36.0 BTU/hr margin).

When should a buyer skip Kohltech International, Ltd. Select Casement and compare alternatives?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Select Casement options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

What Southern ENERGY STAR v7.0 options exist in Select Casement?

Yes, Select Casement holds 23 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.17 SHGC in cooling climates.

How many Kohltech International, Ltd. Select Casement variants earn ENERGY STAR Most Efficient?

Not every package qualifies: 19 of 50 Select Casement glazing builds earn Most Efficient recognition (38.0%), while other variants sit on the standard Version 7.0 tier.

Do 2026 Select Casement installations qualify for IRS Section 25C tax credits?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How do building inspectors verify Select Casement glass specs on job sites?

Inspectors match the temporary NFRC sticker (U 0.16-0.27, SHGC 0.17-0.46) against permit drawings for line KOI-A-66. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Kohltech International, Ltd. Select Casement come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)