Cascadia Windows Ltd. — Universal Series Inswing Tilt-Turn Window · Dual Action (Tilt Turn)
With a minimum U-Factor of 0.09—-0.11 compared against the 0.20 Window median—Cascadia Windows Ltd. Universal Series Inswing Tilt-Turn Window spans 428 tested options across Northern, North-Central, South-Central, Southern up to 0.28 U-Factor. Carrying NFRC CPD code CWL, the Fiberglass assembly includes 201 ENERGY STAR Most Efficient packages (47.0% of line) and offers SHGC packages between 0.05 and 0.46.
- Min U-Factor
- 0.09
- SHGC Range
- 0.05-0.46
- Certified Options
- 428
- Category Standing
- #3 of 1,352
How does Cascadia Windows Ltd. Universal Series Inswing Tilt-Turn Window compare thermally against Window peers?
Cascadia Windows Ltd. Universal Series Inswing Tilt-Turn Window achieves a 0.09 thermal floor across Window lines, placing #3 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Within the Fiberglass cohort (0.19 median U-Factor), Universal Series Inswing Tilt-Turn Window reaches 0.09 on its lowest-conductivity package — #4 of 76 in Fiberglass, tied with 1 other at 0.09, more insulating than 93.4% of Fiberglass lines, top 6.6% (-0.10 vs Fiberglass peers). Pairing NFRC ID CWL across multi-pane fills shifts U-Factor from 0.28 down toward 0.09.
Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 201 configurations meet ENERGY STAR Most Efficient criteria while 138 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Registry history records EPA FENSTAR licensing on 2018-01-12 and v7.0 data certification on 2024-02-28. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.09 conducts 54.0 BTU/hr (-78.0 BTU/hr vs the 0.22 ceiling).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 428 certified glazing combinations for Universal Series Inswing Tilt-Turn Window (NFRC CWL) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 138 packages (71 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 373 packages (181 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 346 packages (142 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 346 packages (161 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.09 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Alpen HPP, LLC dba Alpen High Performance Products — Contour Fixed | Vinyl | 0.09 | 0.17 | 180 |
| Kolbe and Kolbe Millwork Co., Inc — Heritage Direct Set HWC2D | Wood | 0.09 | 0.11 | 1,006 |
| Alpen HPP, LLC dba Alpen High Performance Products — ASPEKT+ Low Profile Fixed | Vinyl | 0.10 | 0.15 | 229 |
| Alpen HPP, LLC dba Alpen High Performance Products — Edge Fixed | Vinyl | 0.10 | 0.17 | 166 |
| Alpen HPP, LLC dba Alpen High Performance Products — Tyrol Fixed Picture | Vinyl | 0.10 | 0.17 | 80 |
What other certified series does Cascadia Windows Ltd. produce?
Compare other active Cascadia Windows Ltd. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
Universal Series Fixed Window Exterior Glazed
U-Factor 0.07–0.29 · 545 certified options.
Universal Series Fixed Window Interior Glazed
U-Factor 0.07–0.29 · 406 certified options.
Universal Series Tilt Slide Door
U-Factor 0.08–0.27 · 579 certified options.
Universal Series Inswing / Outswing Door (Single)
U-Factor 0.09–0.27 · 1,353 certified options.
Universal Series Inswing Hopper Window
U-Factor 0.11–0.28 · 438 certified options.
Universal Series Outswing Awning Window
U-Factor 0.12–0.28 · 600 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Cascadia Windows Ltd. Universal Series Inswing Tilt-Turn Window appear below.
How efficient is Cascadia Windows Ltd. Universal Series Inswing Tilt-Turn Window compared with peer Window models?
Across 428 tested NFRC glazing configurations, Cascadia Windows Ltd. Universal Series Inswing Tilt-Turn Window with Fiberglass framing and Tilt-Turn Dual Action (DATT) style reaches a 0.09 minimum U-Factor and 0.05-0.46 SHGC band. It places #3 among 1,352 Window series—top 0.4%.
Does Cascadia Windows Ltd. Universal Series Inswing Tilt-Turn Window qualify for the ENERGY STAR Northern Zone?
Cold-climate buyers get 138 compliant Northern packages inside Universal Series Inswing Tilt-Turn Window, reaching down to U 0.09. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.28 options.
How much winter heat loss does Universal Series Inswing Tilt-Turn Window conduct across a 15 sq ft opening?
Using NFRC CWL U-Factor 0.09, a 15 sq ft Tilt-Turn Dual Action (DATT) assembly conducts 54.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-78.0 BTU/hr margin).
Who should NOT choose Cascadia Windows Ltd. Universal Series Inswing Tilt-Turn Window for a residential project?
Cold-climate owners needing prescriptive U <= 0.22 should pass on Universal Series Inswing Tilt-Turn Window options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.
How many Universal Series Inswing Tilt-Turn Window glazing packages pass Southern solar-heat rules?
Across Northern, North-Central, South-Central, Southern, 346 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Cascadia Windows Ltd. Universal Series Inswing Tilt-Turn Window, while total line SHGC reaches 0.46 in colder packages.
Does Universal Series Inswing Tilt-Turn Window carry EPA Most Efficient certification across its lineup?
Not every package qualifies: 201 of 428 Universal Series Inswing Tilt-Turn Window glazing builds earn Most Efficient recognition (47.0%), while other variants sit on the standard Version 7.0 tier.
How do the 25C sunset and pre-1978 Lead RRP rules affect Universal Series Inswing Tilt-Turn Window?
In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Universal Series Inswing Tilt-Turn Window retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.
How do building inspectors verify Universal Series Inswing Tilt-Turn Window glass specs on job sites?
Leave the temporary NFRC label intact until inspection to confirm manufacturer code CWL and product line CWL-K-23, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Cascadia Windows Ltd. Universal Series Inswing Tilt-Turn Window come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)