Skip to main content
Door · Vinyl Frame NFRC CMI · Product Line CMI-M-54

Croft LLC — 60PD · Sliding Patio Door

EPA ENERGY STAR Version 7.0 certifies 4 variants inside Croft LLC 60PD, combining Vinyl frame construction with U-Factors spanning 0.28 to 0.28 and SHGC 0.21 to 0.23. Qualifying for South-Central, Southern, this Sliding Patio Door family places #259 of 268 among 268 Door families and posts 0.09 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

Min U-Factor
0.28
SHGC Range
0.21-0.23
Certified Options
4
Category Standing
#259 of 268

How does Croft LLC 60PD compare thermally against Door peers?

Croft LLC 60PD achieves a 0.28 thermal floor across Door lines, placing #259 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. 60PDHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.28-0.30 containing 60PD (U 0.28).28<=0.15650.16-0.18510.19-0.21710.22-0.24430.25-0.27100.28-0.30This model: U 0.2800.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

60PD Cohort StandingMin U-Factor 0.28 stands at rank #259 of 268, outperforming 2.0% of peers.Min U-Factor 0.28Rank #259 of 268 (2.0% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), 60PD reaches 0.28 on its lowest-conductivity package — #984 of 1,009 in Vinyl, tied with 20 others at 0.28, more insulating than 0.5% of Vinyl lines (+0.09 vs Vinyl peers). Pairing NFRC ID CMI across multi-pane fills shifts U-Factor from 0.28 down toward 0.28.

Mapping NFRC SHGC values (0.21 to 0.23) against ENERGY STAR Version 7.0 targets approves South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.21 lowers cooling load.

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 168.0 BTU/hr (+27.3% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-09-11 and cert timestamp 2023-10-29.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 4 certified glazing combinations for 60PD (NFRC CMI) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Not Listed <= 0.25 <= 0.40 0 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 4 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 4 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.28 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Croft LLC 60PD appear below.

How well does 60PD by Croft LLC insulate relative to Door benchmarks?

EPA ENERGY STAR v7.0 records 4 configurations for Croft LLC 60PD covering South-Central, Southern, dropping down to U 0.28 versus a 0.21 Door median. Only 0 options earn Most Efficient status.

How does Croft LLC 60PD satisfy Version 7.0 Northern criteria?

Northern Zone certification is absent for 60PD (0 qualifying options, min U 0.28). Install this Sliding Glass Door (DDSG) product only within South-Central, Southern regions where lower SHGC caps apply.

What conductive BTU/hr difference separates 60PD from the 0.22 Northern rule?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 168.0 BTU/hr on 60PD's lowest-U package (0.28), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.28 transfer proportionally more energy.

What are the practical limitations of specifying 60PD?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 60PD options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

Is 60PD suitable for sunbelt cooling-dominated homes?

Yes, 60PD holds 4 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.21 SHGC in cooling climates.

How many Croft LLC 60PD variants earn ENERGY STAR Most Efficient?

Zero glazing builds inside 60PD's 4 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

Can homeowners claim Form 5695 credits on Croft LLC 60PD in 2026?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

What permanent glass etch marks verify 60PD after sticker removal?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code CMI and product line CMI-M-54, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Croft LLC 60PD come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros