Skip to main content
Door · Aluminum Frame NFRC VWS · Product Line VWS-A-57

Value Windows & Doors — AUC Swing Door · Swinging Entry Door (Single)

Positioning #259/268 in certified Door, Value Windows & Doors AUC Swing Door pairs Aluminum frame construction with 11 glazing options rated between 0.12 and 0.16 SHGC across South-Central, Southern. Across 16 certified Value Windows & Doors product families, its thermal resistance spans 0.28 to 0.28 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

Min U-Factor
0.28
SHGC Range
0.12-0.16
Certified Options
11
Category Standing
#259 of 268

How does Value Windows & Doors AUC Swing Door compare thermally against Door peers?

Value Windows & Doors AUC Swing Door achieves a 0.28 thermal floor across Door lines, placing #259 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. AUC Swing DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.28-0.30 containing AUC Swing Door (U 0.28).28<=0.15650.16-0.18510.19-0.21710.22-0.24430.25-0.27100.28-0.30This model: U 0.2800.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

AUC Swing Door Cohort StandingMin U-Factor 0.28 stands at rank #259 of 268, outperforming 2.0% of peers.Min U-Factor 0.28Rank #259 of 268 (2.0% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across AUC Swing Door spans 11 NFRC test records (VWS), ranking #259 of 268 Door families (tied with 9 others at 0.28, lowest-ranked of 268 Door lines). Its 0.28 thermal floor compares at +0.05 against the Aluminum median (0.23).

Mapping NFRC SHGC values (0.12 to 0.16) against ENERGY STAR Version 7.0 targets approves South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.12 lowers cooling load.

Lifecycle documentation anchors VWS to 2026-11-04 certification (FENSTAR issued 2019-01-31). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 168.0 BTU/hr conductive loss (+27.3% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 11 certified glazing combinations for AUC Swing Door (NFRC VWS) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Not Listed <= 0.25 <= 0.40 0 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 11 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 11 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.28 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
ESWindows LLC — ES-LG450 Bi-fold Door Aluminum 0.28 0.08 48
Croft LLC — 60PD Vinyl 0.28 0.21 4
Vytex Corporation — 7000 Sliding Glass Door Vinyl 0.28 0.20 2
Windsor Windows and Doors — Pinnacle Clad Outswing Door Wood 0.28 0.11 24
Windsor Windows and Doors — Pinnacle Clad Inswing Door Wood 0.28 0.11 25

What other certified series does Value Windows & Doors produce?

Compare other active Value Windows & Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Value Windows & Doors AUC Swing Door appear below.

Where does Value Windows & Doors AUC Swing Door stand thermally among ENERGY STAR Door lines?

Value Windows & Doors AUC Swing Door spans 11 certified configurations with U-Factors between 0.28 and 0.28 and SHGC values from 0.12 to 0.16. Ranked #259 of 268 Door families, it carries 0 Most Efficient options.

Is AUC Swing Door approved for Northern Zone heating climates?

This series is excluded from Northern ENERGY STAR eligibility (0 qualified options; floor U 0.28). Focus on South-Central, Southern glazing applications where SHGC 0.12-0.16 manages cooling loads.

What BTU/hr heat transfer results from AUC Swing Door's 0.28 minimum U-Factor?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), AUC Swing Door at U 0.28 conducts 168.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

What homeowner profiles are a poor match for Value Windows & Doors AUC Swing Door?

Cold-climate owners needing prescriptive U <= 0.22 should pass on AUC Swing Door options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

What Southern ENERGY STAR v7.0 options exist in AUC Swing Door?

Exactly 11 AUC Swing Door options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.12 rather than higher 0.16 glass.

Does AUC Swing Door carry EPA Most Efficient certification across its lineup?

ENERGY STAR Most Efficient designation is absent across all 11 AUC Swing Door options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

What 2026 federal tax credit and Lead RRP rules apply to AUC Swing Door?

Any AUC Swing Door purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How can homeowners confirm delivered Value Windows & Doors AUC Swing Door units match permits?

Inspectors match the temporary NFRC sticker (U 0.28-0.28, SHGC 0.12-0.16) against permit drawings for line VWS-A-57. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Value Windows & Doors AUC Swing Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)