Door · Aluminum Frame NFRC EWN · Product Line EWN-K-65

ESWindows LLC — ES-LG450 Bi-fold Door · Swinging Entry Door (Single)

ESWindows LLC engineered the ES-LG450 Bi-fold Door Swinging Entry Door, Single line for South-Central, Southern, certifying 48 glass-spacer combinations from 0.28 to 0.28 U-Factor and 0.08 to 0.20 SHGC. Relative to other Aluminum models tracked under NFRC EWN, its minimum U-Factor is 0.05 Btu/hr·ft²·°F less insulating than the 0.23 Btu/hr·ft²·°F median.

Min U-Factor
0.28
SHGC Range
0.08-0.20
Certified Options
48
Category Standing
#259 of 268

How does ESWindows LLC ES-LG450 Bi-fold Door compare thermally against Door peers?

ESWindows LLC ES-LG450 Bi-fold Door achieves a 0.28 thermal floor across Door lines, placing #259 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. ES-LG450 Bi-fold DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.28-0.30 containing ES-LG450 Bi-fold Door (U 0.28).28<=0.15650.16-0.18510.19-0.21710.22-0.24430.25-0.27100.28-0.30This model: U 0.2800.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

ES-LG450 Bi-fold Door Cohort StandingMin U-Factor 0.28 stands at rank #259 of 268, outperforming 2.0% of peers.Min U-Factor 0.28Rank #259 of 268 (2.0% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 268 ENERGY STAR v7.0 Door lines places ESWindows LLC ES-LG450 Bi-fold Door at rank #259 of 268 (tied with 9 others at 0.28, lowest-ranked of 268 Door lines; cohort median 0.21). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.08-0.20 band.

Climate coverage for ESWindows LLC ES-LG450 Bi-fold Door spans South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.08 lowers cooling load.

Data provenance links certification 2026-07-30 and FENSTAR license 2024-09-19 inside EPA Version 7.0 tables. Heat transfer computes to 168.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 48 certified glazing combinations for ES-LG450 Bi-fold Door (NFRC EWN) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Not Listed <= 0.25 <= 0.40 0 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 48 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 48 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.28 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does ESWindows LLC produce?

Compare other active ESWindows LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to ESWindows LLC ES-LG450 Bi-fold Door appear below.

What thermal performance numbers separate ESWindows LLC ES-LG450 Bi-fold Door from peers?

EPA ENERGY STAR v7.0 records 48 configurations for ESWindows LLC ES-LG450 Bi-fold Door covering South-Central, Southern, dropping down to U 0.28 versus a 0.21 Door median. Only 0 options earn Most Efficient status.

Can homeowners install ES-LG450 Bi-fold Door in cold Northern ENERGY STAR counties?

This series is excluded from Northern ENERGY STAR eligibility (0 qualified options; floor U 0.28). Focus on South-Central, Southern glazing applications where SHGC 0.08-0.20 manages cooling loads.

How do you calculate winter heat conduction for ESWindows LLC ES-LG450 Bi-fold Door?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 168.0 BTU/hr on ES-LG450 Bi-fold Door's lowest-U package (0.28), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.28 transfer proportionally more energy.

Which situations make ES-LG450 Bi-fold Door the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on ES-LG450 Bi-fold Door options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

What Southern ENERGY STAR v7.0 options exist in ES-LG450 Bi-fold Door?

Across South-Central, Southern, 48 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside ESWindows LLC ES-LG450 Bi-fold Door, while total line SHGC reaches 0.20 in colder packages.

Are all 48 ES-LG450 Bi-fold Door configurations ENERGY STAR Most Efficient?

No. Zero of the 48 configurations in ESWindows LLC ES-LG450 Bi-fold Door hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.

What federal compliance checks govern 2026 ES-LG450 Bi-fold Door window swaps?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current ES-LG450 Bi-fold Door retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

How do building inspectors verify ES-LG450 Bi-fold Door glass specs on job sites?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code EWN and product line EWN-K-65, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for ESWindows LLC ES-LG450 Bi-fold Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros