Positioning #133/268 in certified Door, ESWindows LLC ES-V76 Side Hinged Door pairs Vinyl frame construction with 99 glazing options rated between 0.10 and 0.24 SHGC across Northern, North-Central, South-Central, Southern. Across 13 certified ESWindows LLC product families, its thermal resistance spans 0.21 to 0.28 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

Min U-Factor
0.21
SHGC Range
0.10-0.24
Certified Options
99
Category Standing
#133 of 268

How does ESWindows LLC ES-V76 Side Hinged Door compare thermally against Door peers?

ESWindows LLC ES-V76 Side Hinged Door achieves a 0.21 thermal floor across Door lines, placing #133 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. ES-V76 Side Hinged DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing ES-V76 Side Hinged Door (U 0.21).28<=0.15650.16-0.18510.19-0.21This model: U 0.21710.22-0.24430.25-0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

ES-V76 Side Hinged Door Cohort StandingMin U-Factor 0.21 stands at rank #133 of 268, outperforming 46.3% of peers.Min U-Factor 0.21Rank #133 of 268 (46.3% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 13 certified ESWindows LLC series, this Swinging Entry Door, Single offers a 0.07 U-Factor adjustment span between 0.28 entry options and 0.21 top-performing glazing. Category standing is #133/268 (tied with 11 others at 0.21, more insulating than 46.3% of Door lines).

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 81 combinations qualify in the Northern Zone alongside 92 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Data provenance links certification 2026-09-16 and FENSTAR license 2024-09-19 inside EPA Version 7.0 tables. Heat transfer computes to 126.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 99 certified glazing combinations for ES-V76 Side Hinged Door (NFRC EWN) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 81 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 81 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 92 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 92 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does ESWindows LLC produce?

Compare other active ESWindows LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to ESWindows LLC ES-V76 Side Hinged Door appear below.

What thermal performance numbers separate ESWindows LLC ES-V76 Side Hinged Door from peers?

Across 99 tested NFRC glazing configurations, ESWindows LLC ES-V76 Side Hinged Door with Vinyl framing and Entry Door Single-Lite (EDSL) style reaches a 0.21 minimum U-Factor and 0.10-0.24 SHGC band. It places #133 among 268 Door series—more insulating than 46.3%.

Which glazing options in ESWindows LLC ES-V76 Side Hinged Door meet Northern climate limits?

Prescriptive Northern compliance covers 81 ES-V76 Side Hinged Door packages (U floor 0.21, SHGC >= 0.17). Because the complete series stretches up to U 0.28, specify the cold-climate glass code explicitly.

What conductive BTU/hr difference separates ES-V76 Side Hinged Door from the 0.22 Northern rule?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.21 U-Factor yields 126.0 BTU/hr conductive transfer (-4.5% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

Which situations make ES-V76 Side Hinged Door the wrong window or door choice?

Skip ES-V76 Side Hinged Door if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on ES-V76 Side Hinged Door options exceeding U 0.22.

How many ES-V76 Side Hinged Door glazing packages pass Southern solar-heat rules?

Exactly 92 ES-V76 Side Hinged Door options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.10 rather than higher 0.24 glass.

Which package tier in ES-V76 Side Hinged Door holds Most Efficient recognition?

No. Zero of the 99 configurations in ESWindows LLC ES-V76 Side Hinged Door hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.

Do 2026 ES-V76 Side Hinged Door installations qualify for IRS Section 25C tax credits?

Any ES-V76 Side Hinged Door purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

Where are NFRC and IGCC identification marks located on ES-V76 Side Hinged Door?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code EWN and product line EWN-K-75, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for ESWindows LLC ES-V76 Side Hinged Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros