ESWindows LLC — ES-LG250 Casement Window · Casement Windows
Positioning #1,256/1,352 in certified Window, ESWindows LLC ES-LG250 Casement Window pairs Aluminum frame construction with 333 glazing options rated between 0.09 and 0.23 SHGC across South-Central, Southern. Across 13 certified ESWindows LLC product families, its thermal resistance spans 0.26 to 0.32 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.
- Min U-Factor
- 0.26
- SHGC Range
- 0.09-0.23
- Certified Options
- 333
- Category Standing
- #1,256 of 1,352
How does ESWindows LLC ES-LG250 Casement Window compare thermally against Window peers?
ESWindows LLC ES-LG250 Casement Window achieves a 0.26 thermal floor across Window lines, placing #1,256 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Within the Aluminum cohort (0.23 median U-Factor), ES-LG250 Casement Window reaches 0.26 on its lowest-conductivity package — #39 of 64 in Aluminum, tied with 5 others at 0.26, more insulating than 31.2% of Aluminum lines (+0.03 vs Aluminum peers). Pairing NFRC ID EWN across multi-pane fills shifts U-Factor from 0.32 down toward 0.26.
Mapping NFRC SHGC values (0.09 to 0.23) against ENERGY STAR Version 7.0 targets approves South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.09 lowers cooling load.
Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.26 U-Factor yields 156.0 BTU/hr transfer (+24.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2024-09-19 licensing and 2026-06-17 certification.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 333 certified glazing combinations for ES-LG250 Casement Window (NFRC EWN) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| North-Central | Not Listed | <= 0.25 | <= 0.40 | 0 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 118 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 333 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.26 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Value Windows & Doors — AUC-XO Horizontal Slider | Aluminum | 0.26 | 0.13 | 20 |
| Andersen Corporation — 400 Series Woodwright® Double- Hung Insert Window | Wood | 0.26 | 0.15 | 333 |
| Andersen Corporation — 400 Series Tilt-Wash Double-Hung Insert Window | Wood | 0.26 | 0.14 | 326 |
| Andersen Corporation — 200 Series Gliding Window | Wood | 0.26 | 0.14 | 383 |
| Windsor Windows and Doors — Pinnacle Clad Win-Pac | Wood | 0.26 | 0.14 | 267 |
What other certified series does ESWindows LLC produce?
Compare other active ESWindows LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
ES-V76 Side Hinged Door
U-Factor 0.21–0.28 · 99 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to ESWindows LLC ES-LG250 Casement Window appear below.
Where does ESWindows LLC ES-LG250 Casement Window stand thermally among ENERGY STAR Window lines?
EPA ENERGY STAR v7.0 records 333 configurations for ESWindows LLC ES-LG250 Casement Window covering South-Central, Southern, dropping down to U 0.26 versus a 0.20 Window median. Only 0 options earn Most Efficient status.
How does ESWindows LLC ES-LG250 Casement Window satisfy Version 7.0 Northern criteria?
No—with 0 Northern packages and a 0.26 thermal floor, ESWindows LLC ES-LG250 Casement Window targets warmer South-Central, Southern climates instead of cold Northern installations.
What conductive BTU/hr difference separates ES-LG250 Casement Window from the 0.22 Northern rule?
Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.26 U-Factor yields 156.0 BTU/hr conductive transfer (+18.2% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.
Which situations make ES-LG250 Casement Window the wrong window or door choice?
Skip ES-LG250 Casement Window if local historic preservation boards prohibit Aluminum profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on ES-LG250 Casement Window options exceeding U 0.22.
Does ES-LG250 Casement Window meet Southern hot-climate SHGC caps (<= 0.23)?
Exactly 333 ES-LG250 Casement Window options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.09 rather than higher 0.23 glass.
Does ES-LG250 Casement Window carry EPA Most Efficient certification across its lineup?
ENERGY STAR Most Efficient designation is absent across all 333 ES-LG250 Casement Window options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.
Can homeowners claim Form 5695 credits on ESWindows LLC ES-LG250 Casement Window in 2026?
Tax rules ended Section 25C on December 31, 2025, shifting 2026 ESWindows LLC upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.
How can homeowners confirm delivered ESWindows LLC ES-LG250 Casement Window units match permits?
Leave the temporary NFRC label intact until inspection to confirm manufacturer code EWN and product line EWN-K-67, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for ESWindows LLC ES-LG250 Casement Window come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)