Skip to main content
Window · Aluminum Frame NFRC VWS · Product Line VWS-A-58

Value Windows & Doors — AUC-XO Horizontal Slider · Single Slider

Across 16 Value Windows & Doors certified families, AUC-XO Horizontal Slider supplies 20 Single Slider configurations starting at 0.26 U-Factor and 0.13 SHGC for South-Central, Southern, reaching up to 0.28 U-Factor and 0.18 SHGC. Its thermal floor ranks #1,256 of 1,352 category entries—0.06 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.26
SHGC Range
0.13-0.18
Certified Options
20
Category Standing
#1,256 of 1,352

How does Value Windows & Doors AUC-XO Horizontal Slider compare thermally against Window peers?

Value Windows & Doors AUC-XO Horizontal Slider achieves a 0.26 thermal floor across Window lines, placing #1,256 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. AUC-XO Horizontal SliderHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing AUC-XO Horizontal Slider (U 0.26).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.26310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

AUC-XO Horizontal Slider Cohort StandingMin U-Factor 0.26 stands at rank #1,256 of 1,352, outperforming 4.5% of peers.Min U-Factor 0.26Rank #1,256 of 1,352 (4.5% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across AUC-XO Horizontal Slider spans 20 NFRC test records (VWS), ranking #1,256 of 1,352 Window families (tied with 35 others at 0.26, more insulating than 4.5% of Window lines). Its 0.26 thermal floor compares at +0.03 against the Aluminum median (0.23).

Evaluating climate compliance across South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.13 lowers cooling load.

Registry history records EPA FENSTAR licensing on 2019-01-31 and v7.0 data certification on 2024-07-30. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.26 conducts 156.0 BTU/hr (+24.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 20 certified glazing combinations for AUC-XO Horizontal Slider (NFRC VWS) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Not Listed <= 0.25 <= 0.40 0 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 20 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 20 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.26 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
ESWindows LLC — ES-LG250 Casement Window Aluminum 0.26 0.09 333
Star Windows — 9230 Single Hung Vinyl 0.26 0.20 17
Neuma Door — Outswing Transom Composite 0.26 0.17 13
Neuma Door — Inswing Transom Composite 0.26 0.17 12
Comfort View Products, LLC — 1920 Horizontal Slider Vinyl 0.26 0.20 33

What other certified series does Value Windows & Doors produce?

Compare other active Value Windows & Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Value Windows & Doors AUC-XO Horizontal Slider appear below.

Where does Value Windows & Doors AUC-XO Horizontal Slider stand thermally among ENERGY STAR Window lines?

Testing puts Value Windows & Doors AUC-XO Horizontal Slider at rank #1,256 of 1,352 Window entries with U 0.26 to 0.28 across 20 configurations. Solar heat gain ranges between 0.13 and 0.18 across South-Central, Southern.

Does Value Windows & Doors AUC-XO Horizontal Slider qualify for the ENERGY STAR Northern Zone?

This series is excluded from Northern ENERGY STAR eligibility (0 qualified options; floor U 0.26). Focus on South-Central, Southern glazing applications where SHGC 0.13-0.18 manages cooling loads.

What BTU/hr heat transfer results from AUC-XO Horizontal Slider's 0.26 minimum U-Factor?

Using NFRC VWS U-Factor 0.26, a 15 sq ft Horizontal Slider (HSOX) assembly conducts 156.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+24.0 BTU/hr margin).

What are the practical limitations of specifying AUC-XO Horizontal Slider?

Skip AUC-XO Horizontal Slider if local historic preservation boards prohibit Aluminum profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on AUC-XO Horizontal Slider options exceeding U 0.22.

Is AUC-XO Horizontal Slider suitable for sunbelt cooling-dominated homes?

Yes, AUC-XO Horizontal Slider holds 20 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.13 SHGC in cooling climates.

Which package tier in AUC-XO Horizontal Slider holds Most Efficient recognition?

AUC-XO Horizontal Slider holds zero Most Efficient entries across its 20 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

Do 2026 AUC-XO Horizontal Slider installations qualify for IRS Section 25C tax credits?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current AUC-XO Horizontal Slider retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

Where are NFRC and IGCC identification marks located on AUC-XO Horizontal Slider?

Confirm both the paper NFRC label and permanent corner glass etch match line VWS-A-58 and NFRC ID VWS before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Value Windows & Doors AUC-XO Horizontal Slider come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros