Neuma Door — Outswing Transom · Transom
Neuma Door Outswing Transom is a Transom assembly with a Composite frame that reaches a minimum U-Factor of 0.26 across 13 certified glazing configurations covering Northern, South-Central, Southern. Ranked #1,256 of 1,352 in Window, its thermal floor is 0.06 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.17 to 0.40.
- Min U-Factor
- 0.26
- SHGC Range
- 0.17-0.40
- Certified Options
- 13
- Category Standing
- #1,256 of 1,352
How does Neuma Door Outswing Transom compare thermally against Window peers?
Neuma Door Outswing Transom achieves a 0.26 thermal floor across Window lines, placing #1,256 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Within the Composite cohort (0.22 median U-Factor), Outswing Transom reaches 0.26 on its lowest-conductivity package — #17 of 21 in Composite, tied with 1 other at 0.26, more insulating than 14.3% of Composite lines (+0.04 vs Composite peers). Pairing NFRC ID NND across multi-pane fills shifts U-Factor from 0.32 down toward 0.26.
Evaluating climate compliance across Northern, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Although its 0.26 floor sits above the 0.22 prescriptive Northern ceiling, 1 Northern package qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).
Lifecycle documentation anchors NND to 2025-03-11 certification (FENSTAR issued 2018-01-23). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 156.0 BTU/hr conductive loss (+18.2% vs the 132.0 BTU/hr baseline at U=0.22).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 13 certified glazing combinations for Outswing Transom (NFRC NND) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Equiv. Path | <= 0.22 | >= 0.17 | 1 package (0 Most Eff.) |
| North-Central | Not Listed | <= 0.25 | <= 0.40 | 0 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 9 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 12 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.26 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Star Windows — 9230 Single Hung | Vinyl | 0.26 | 0.20 | 17 |
| Value Windows & Doors — AUC-XO Horizontal Slider | Aluminum | 0.26 | 0.13 | 20 |
| KP Building Products Limited — 3900/3901 Hopper Window | Vinyl | 0.26 | 0.16 | 2 |
| Window Mart — 8500 Picture Window | Vinyl | 0.26 | 0.22 | 1 |
| Comfort View Products, LLC — 1920 Horizontal Slider | Vinyl | 0.26 | 0.20 | 33 |
What other certified series does Neuma Door produce?
Compare other active Neuma Door certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
Inswing/Outswing Hinged Entry Door
U-Factor 0.14–0.28 · 7,646 certified options.
Neuma Hinged Door
U-Factor 0.16–0.28 · 195 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Neuma Door Outswing Transom appear below.
What thermal performance numbers separate Neuma Door Outswing Transom from peers?
Across 13 tested NFRC glazing configurations, Neuma Door Outswing Transom with Composite framing and Fixed Transom (FXTR) style reaches a 0.26 minimum U-Factor and 0.17-0.40 SHGC band. It places #1,256 among 1,352 Window series—more insulating than 4.5%.
Which glazing options in Neuma Door Outswing Transom meet Northern climate limits?
Prescriptive Northern approval ends at U <= 0.22, above Outswing Transom's 0.26 minimum. However, 1 Northern package pass EPA Equivalent compliance by pairing higher solar gain (SHGC >= 0.35 or 0.40) with <= 0.3 cfm/ft2 air leakage.
How do you calculate winter heat conduction for Neuma Door Outswing Transom?
Conductive heat flow equals U x 15 sq ft x 40 deg F = 156.0 BTU/hr on Outswing Transom's lowest-U package (0.26), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.
Which situations make Outswing Transom the wrong window or door choice?
Cold-climate owners needing prescriptive U <= 0.22 should pass on Outswing Transom options exceeding U 0.22. Additionally, do not order Fixed Transom (FXTR) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).
Does Outswing Transom meet Southern hot-climate SHGC caps (<= 0.23)?
Yes. 12 Southern-certified options inside Neuma Door Outswing Transom satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.40 SHGC on west-facing glass to avoid excess afternoon solar gain.
Does Outswing Transom carry EPA Most Efficient certification across its lineup?
Zero glazing builds inside Outswing Transom's 13 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.
What 2026 federal tax credit and Lead RRP rules apply to Outswing Transom?
No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.
How can homeowners confirm delivered Neuma Door Outswing Transom units match permits?
Leave the temporary NFRC label intact until inspection to confirm manufacturer code NND and product line NND-M-10, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Neuma Door Outswing Transom come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)