Window · Vinyl Frame NFRC CVP · Product Line CVP-M-18

Comfort View Products, LLC — 1920 Horizontal Slider · Single Slider

Across 6 Comfort View Products, LLC certified families, 1920 Horizontal Slider supplies 33 Single Slider configurations starting at 0.26 U-Factor and 0.20 SHGC for South-Central, Southern, reaching up to 0.32 U-Factor and 0.22 SHGC. Its thermal floor ranks #1,256 of 1,352 category entries—0.06 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.26
SHGC Range
0.20-0.22
Certified Options
33
Category Standing
#1,256 of 1,352

How does Comfort View Products, LLC 1920 Horizontal Slider compare thermally against Window peers?

Comfort View Products, LLC 1920 Horizontal Slider achieves a 0.26 thermal floor across Window lines, placing #1,256 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 1920 Horizontal SliderHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing 1920 Horizontal Slider (U 0.26).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.26310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

1920 Horizontal Slider Cohort StandingMin U-Factor 0.26 stands at rank #1,256 of 1,352, outperforming 4.5% of peers.Min U-Factor 0.26Rank #1,256 of 1,352 (4.5% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Comfort View Products, LLC 1920 Horizontal Slider at rank #1,256 of 1,352 (tied with 35 others at 0.26, more insulating than 4.5% of Window lines; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.20-0.22 band.

Mapping NFRC SHGC values (0.20 to 0.22) against ENERGY STAR Version 7.0 targets approves South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.20 lowers cooling load.

Lifecycle documentation anchors CVP to 2025-01-09 certification (FENSTAR issued 2018-01-10). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 156.0 BTU/hr conductive loss (+18.2% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 33 certified glazing combinations for 1920 Horizontal Slider (NFRC CVP) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Not Listed <= 0.25 <= 0.40 0 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 6 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 33 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.26 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
REHAU, S.A. DE C.V. — S190 Single Slider Vinyl 0.26 0.14 44
Star Windows — 9230 Single Hung Vinyl 0.26 0.20 17
KP Building Products Limited — 3900/3901 Hopper Window Vinyl 0.26 0.16 2
Window Mart — 8500 Picture Window Vinyl 0.26 0.22 1
Gerkin Windows and Doors — 6100 Single Hung Vinyl 0.26 0.14 91

What other certified series does Comfort View Products, LLC produce?

Compare other active Comfort View Products, LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Comfort View Products, LLC 1920 Horizontal Slider appear below.

How well does 1920 Horizontal Slider by Comfort View Products, LLC insulate relative to Window benchmarks?

Comfort View Products, LLC 1920 Horizontal Slider spans 33 certified configurations with U-Factors between 0.26 and 0.32 and SHGC values from 0.20 to 0.22. Ranked #1,256 of 1,352 Window families, it carries 0 Most Efficient options.

Is 1920 Horizontal Slider approved for Northern Zone heating climates?

No. Because 1920 Horizontal Slider reaches only 0.26 U-Factor with 0 Northern combinations, it is not approved for ENERGY STAR Northern counties. Specify this Vinyl line strictly across South-Central, Southern cooling or mixed markets.

What BTU/hr heat transfer results from 1920 Horizontal Slider's 0.26 minimum U-Factor?

Using NFRC CVP U-Factor 0.26, a 15 sq ft Horizontal Slider (HSOX) assembly conducts 156.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+24.0 BTU/hr margin).

Who should NOT choose Comfort View Products, LLC 1920 Horizontal Slider for a residential project?

Skip 1920 Horizontal Slider if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on 1920 Horizontal Slider options exceeding U 0.22.

Does 1920 Horizontal Slider meet Southern hot-climate SHGC caps (<= 0.23)?

Yes, 1920 Horizontal Slider holds 33 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.20 SHGC in cooling climates.

Does 1920 Horizontal Slider carry EPA Most Efficient certification across its lineup?

No. Zero of the 33 configurations in Comfort View Products, LLC 1920 Horizontal Slider hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.

What federal compliance checks govern 2026 1920 Horizontal Slider window swaps?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Comfort View Products, LLC upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How can homeowners confirm delivered Comfort View Products, LLC 1920 Horizontal Slider units match permits?

Inspectors match the temporary NFRC sticker (U 0.26-0.32, SHGC 0.20-0.22) against permit drawings for line CVP-M-18. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Comfort View Products, LLC 1920 Horizontal Slider come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros