Skip to main content
Window · Vinyl Frame NFRC CVP · Product Line CVP-M-19

Comfort View Products, LLC — 1901 Picture Window · Picture Window

Positioning #1,034/1,352 in certified Window, Comfort View Products, LLC 1901 Picture Window pairs Vinyl frame construction with 40 glazing options rated between 0.21 and 0.31 SHGC across North-Central, South-Central, Southern. Across 6 certified Comfort View Products, LLC product families, its thermal resistance spans 0.24 to 0.32 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

Min U-Factor
0.24
SHGC Range
0.21-0.31
Certified Options
40
Category Standing
#1,034 of 1,352

How does Comfort View Products, LLC 1901 Picture Window compare thermally against Window peers?

Comfort View Products, LLC 1901 Picture Window achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 1901 Picture WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing 1901 Picture Window (U 0.24).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

1901 Picture Window Cohort StandingMin U-Factor 0.24 stands at rank #1,034 of 1,352, outperforming 13.2% of peers.Min U-Factor 0.24Rank #1,034 of 1,352 (13.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 6 certified Comfort View Products, LLC series, this Picture Window offers a 0.08 U-Factor adjustment span between 0.32 entry options and 0.24 top-performing glazing. Category standing is #1,034/1,352 (tied with 139 others at 0.24, more insulating than 13.2% of Window lines).

Regional qualification covers North-Central, South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.21 lowers cooling load.

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 144.0 BTU/hr (+9.1% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2024-04-03.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 40 certified glazing combinations for 1901 Picture Window (NFRC CVP) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 10 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 20 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 35 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Comfort View Products, LLC produce?

Compare other active Comfort View Products, LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Comfort View Products, LLC 1901 Picture Window appear below.

Where does Comfort View Products, LLC 1901 Picture Window stand thermally among ENERGY STAR Window lines?

Comfort View Products, LLC 1901 Picture Window spans 40 certified configurations with U-Factors between 0.24 and 0.32 and SHGC values from 0.21 to 0.31. Ranked #1,034 of 1,352 Window families, it carries 0 Most Efficient options.

Which glazing options in Comfort View Products, LLC 1901 Picture Window meet Northern climate limits?

Comfort View Products, LLC 1901 Picture Window holds zero Northern Zone qualifications (min U 0.24). Homeowners in northern heating zones should skip this line and select an assembly reaching <= 0.22 U-Factor or Equivalent SHGC.

What BTU/hr heat transfer results from 1901 Picture Window's 0.24 minimum U-Factor?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.24 U-Factor yields 144.0 BTU/hr conductive transfer (+9.1% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

Which situations make 1901 Picture Window the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 1901 Picture Window options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

How many 1901 Picture Window glazing packages pass Southern solar-heat rules?

Warm-climate homeowners have 35 Southern-approved options within 1901 Picture Window spanning SHGC down to 0.21. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

How many Comfort View Products, LLC 1901 Picture Window variants earn ENERGY STAR Most Efficient?

1901 Picture Window holds zero Most Efficient entries across its 40 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

Can homeowners claim Form 5695 credits on Comfort View Products, LLC 1901 Picture Window in 2026?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Comfort View Products, LLC upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

What permanent glass etch marks verify 1901 Picture Window after sticker removal?

Match the NFRC thermal sticker for code CVP and line CVP-M-19 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Comfort View Products, LLC 1901 Picture Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)