L.A.S. Enterprises — Weathergard II - Vinyl Picture · Picture Window
With a minimum U-Factor of 0.24—+0.04 compared against the 0.20 Window median—L.A.S. Enterprises Weathergard II - Vinyl Picture spans 44 tested options across Northern, North-Central, South-Central, Southern up to 0.25 U-Factor. Carrying NFRC CPD code LSE, the Vinyl assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.14 and 0.56.
- Min U-Factor
- 0.24
- SHGC Range
- 0.14-0.56
- Certified Options
- 44
- Category Standing
- #1,034 of 1,352
How does L.A.S. Enterprises Weathergard II - Vinyl Picture compare thermally against Window peers?
L.A.S. Enterprises Weathergard II - Vinyl Picture achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Compared across 5 certified L.A.S. Enterprises series, this Picture Window offers a 0.01 U-Factor adjustment span between 0.25 entry options and 0.24 top-performing glazing. Category standing is #1,034/1,352 (tied with 139 others at 0.24, more insulating than 13.2% of Window lines).
Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 4 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).
Lifecycle documentation anchors LSE to 2025-08-28 certification (FENSTAR issued 2018-10-03). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 144.0 BTU/hr conductive loss (+9.1% vs the 132.0 BTU/hr baseline at U=0.22).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 44 certified glazing combinations for Weathergard II - Vinyl Picture (NFRC LSE) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Equiv. Path | <= 0.22 | >= 0.17 | 4 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 40 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 40 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 40 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Target Windows and Doors — SL 3000 Single Hung | Vinyl | 0.24 | 0.20 | 42 |
| Target Windows and Doors — SL 3050 Single Slider | Vinyl | 0.24 | 0.20 | 42 |
| California Deluxe Windows Industries, Inc. — S-3725/3735 Single Slider | Vinyl | 0.24 | 0.12 | 40 |
| Comfort View Products, LLC — 1901 Picture Window | Vinyl | 0.24 | 0.21 | 40 |
| Crystal Window and Door Systems, Ltd. — 100 Series Double Hung | Vinyl | 0.24 | 0.16 | 48 |
What other certified series does L.A.S. Enterprises produce?
Compare other active L.A.S. Enterprises certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
Weathergard II - Vinyl Double Hung
U-Factor 0.19–0.29 · 210 certified options.
Weathergard II - Vinyl Double Slider
U-Factor 0.19–0.29 · 210 certified options.
Weathergard II - Vinyl Casement
U-Factor 0.24–0.25 · 44 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to L.A.S. Enterprises Weathergard II - Vinyl Picture appear below.
How efficient is L.A.S. Enterprises Weathergard II - Vinyl Picture compared with peer Window models?
Built with Vinyl framing in Fixed Window (FIXD) style, L.A.S. Enterprises Weathergard II - Vinyl Picture offers 44 Version 7.0 configurations from U 0.24 up to 0.25, posting +0.04 against the Window median of 0.20 with 0 Most Efficient picks.
Which glazing options in L.A.S. Enterprises Weathergard II - Vinyl Picture meet Northern climate limits?
Prescriptive Northern approval ends at U <= 0.22, above Weathergard II - Vinyl Picture's 0.24 minimum. However, 4 Northern packages pass EPA Equivalent compliance by pairing higher solar gain (SHGC >= 0.35 or 0.40) with <= 0.3 cfm/ft2 air leakage.
How much winter heat loss does Weathergard II - Vinyl Picture conduct across a 15 sq ft opening?
At U 0.24, a standard 3x5 ft (15 sq ft) Weathergard II - Vinyl Picture opening transfers 144.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +12.0 BTU/hr difference.
What are the practical limitations of specifying Weathergard II - Vinyl Picture?
Do not specify Weathergard II - Vinyl Picture without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Weathergard II - Vinyl Picture options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.
Does Weathergard II - Vinyl Picture meet Southern hot-climate SHGC caps (<= 0.23)?
Warm-climate homeowners have 40 Southern-approved options within Weathergard II - Vinyl Picture spanning SHGC down to 0.14. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.
Does Weathergard II - Vinyl Picture carry EPA Most Efficient certification across its lineup?
Weathergard II - Vinyl Picture holds zero Most Efficient entries across its 44 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.
What federal compliance checks govern 2026 Weathergard II - Vinyl Picture window swaps?
In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Weathergard II - Vinyl Picture retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.
How do building inspectors verify Weathergard II - Vinyl Picture glass specs on job sites?
Verify NFRC ID LSE and series LSE-M-7 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for L.A.S. Enterprises Weathergard II - Vinyl Picture come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)